video corpo

Pulsar-18
6Pages

{{requestButtons}}

Catalog excerpts

Pulsar-18 - 1

Clinically proven Technical data/ ordering info Vascular Intervention // Peripheral BIOTRONIKSelf-Expanding Stent System/0.018'7QTW w excellence for life

Open the catalog to page 1
Pulsar-18 - 2

140 pm thin struts - thinner than the leading brands1 Thinner struts for low Chronic Outward Force (COF)2 Stent strut thickness in perspective1 Pulsar-18 BIOTRONIK Pulsar-18 BIOTRONIK Zilver Flex Cook Medical Innova Boston Scientific EverFlex Entrust Medtronic Lifestent XL BARD Zilver Flex Cook Medical Thinner struts and lower COF make a difference:* • Lower risk of restenosis3 • Reduced vessel injury and inflammation4 • Faster endothelialization5 *As demonstrated in pre-clinical studies Innova Boston Scientific T _l_ 213 pm EverFlex Entrust Medtronic Pulsar Stent BIOTRONIK Low COF

Open the catalog to page 2
Pulsar-18 - 3

Clinically provenLong term safety and efficacy (12 month data) 4F INTERVENTIONS 4EVER7 ** FTLR - Freedom from Target Lesion Revascularization; +PP - Primary Patency; ++A.L.L. - Average Lesion Length (Courtesy of Prof. van den Berg) BIOFLEX PEACE Pulsar-18 (BIOTRONIK)10 RESILIENT Lifestent (Bard)11 SUPERB Supera (Abbott)12 SuperNOVA Innova (Boston Scientific)13 Zilver PTX Zilver Flex Arm* (Cook Medical)14 Durability Protege EverFlex (Medtronic)15 Results from different trials are not directly comparable. Differences in outcomes may be the result of differences in protocol design, patient...

Open the catalog to page 3
Pulsar-18 - 4

0 Stent designed for SFA* Multi-directional flexibility to conform to the natural vessel movement. ^Superficial Femoral Artery Low axial stiffness for high flexibility16 Supera Abbott Pulsar-18 BIOTRONIK Lifestent XL BARD Innova Boston Scientific EverFlex Entrust Medtronic Zilver Flex Cook Medical Bending Peak-to-valley design and S-articulating connecting bars provide multi-directional flexibility and avoid fish scaling in mobile vessel architecture.17

Open the catalog to page 4
Pulsar-18 - 5

smaller puncture site area than 6F18 4F Low Profile - Improved 7 acute outcomes vs. 6F Potential for safer, faster and simpler procedures than 6F • Clinically proven lower access site complication rates7 • Shorter compression time • 45% smaller puncture site area than 6F • No need for a closure device Stent deployment One-handed stent release handle, ergonomically designed for a comfortable and stable handling.

Open the catalog to page 5
Pulsar-18 - 6

Pulsar-18 Indicated for use in patients with atherosclerotic disease of the femoral and infrapopliteal arteries and for the treatment of insufficient results after percutaneous transluminal angioplasty.* Vascular Intervention Peripheral Technical Data Stent Recommended guide wire 0.018” Stent material Nitinol Stent coating proBIO (Amorphous Silicon Carbide) Stent Markers 6 gold markers each end Proximal shaft 3.6F, hydrophobic coating Stent Ordering Information 0 (mm) Catheter length 90 cm (Stent length mm) **8 weeks pre-order only 1. 6.0 mm diameters. BIOTRONIK data on file; 2. 6.0 mm...

Open the catalog to page 6

All Biotronik catalogs and technical brochures

  1. Orsiro

    6 Pages

  2. Pantera Pro

    5 Pages

  3. 3Flow

    2 Pages

  4. Magmaris

    6 Pages

  5. Passeo-35 HP

    4 Pages

  6. Galeo Pro

    2 Pages

  7. Fortress

    3 Pages

  8. Passeo-35 HP

    3 Pages

  9. Passeo-35

    3 Pages

  10. Passeo-18

    3 Pages

  11. Passeo-14

    3 Pages

  12. PK Papyrus

    4 Pages

  13. Astron

    4 Pages

  14. Pantera LEO

    5 Pages

  15. Lumax 740

    1 Pages

  16. BioMonitor

    8 Pages

  17. Protego

    6 Pages

  18. Idova 7

    8 Pages

  19. PRO-Kinetic

    12 Pages

  20. Magnum

    2 Pages

  21. Galeo

    8 Pages

  22. Streamer

    2 Pages

  23. Pacemaker

    48 Pages