BLACKFISH INDUSTRIES (SHANGHAI) CO.,LTD The Manual of Medical Gas Alarm (BFZGAE series) Blackfish Industries (Shanghai) Co.,Ltd Since 1999

 Open the catalog to page 1
Blackfish,hospital gas monitoring,gas alarm,BFZGAE-2

BLACKFISH INDUSTRIES (SHANGHAI) CO.,LTD The LED gas alarm (item No. BFZGAE) is designed by Blackfish,today it is the 3rd generation alarm with following new function: 1) ,electric power: AC100--240V. DC 9V±5%; 2) ,power: 1gas--2W, 2gases---3W, 3gases--4W, 4gases--5W, 5gases--6W, 6gases--7W, 7gases--8W; 3) ,monitoring: -0.1Mpa to 1.0Mpa. (-14.51psi to 1451psi); 4) ,to monitor 7 gases at maximum; 5) ,LED size:0.8 inch; 6) ,default unit: Mpa(positive pressure) and kPa(vacuum), PSI (positive pressure) and inHg(vacuum), Bar(positive pressure) and mmHg(vacuum), 7) ,with RS-485 remote communication;...

 Open the catalog to page 2
Blackfish,hospital gas monitoring,gas alarm,BFZGAE-3

BLACKFISH INDUSTRIES (SHANGHAI) CO.,LTD TEST:all indicators will be lighting when pressed,meanwhile gas alarm testing itself,it means normal when all lighting,and return to work status in 6 seconds; ALARM SILENCE: pressed once time,only lighting alarm,without sound alarm when gas pressure not normal, Pressed again,lighting and buzzer alarm,without sound still,when gas pressure not normal; When the LED displays”- - - -”,it means something wrong of sensors

 Open the catalog to page 3
Blackfish,hospital gas monitoring,gas alarm,BFZGAE-4

BLACKFISH INDUSTRIES (SHANGHAI) CO.,LTD unpacking the panel,it will be shown like this: To set each gas by 3 buttons 1.press M key,high alarm lighting,press↑or↓to adjust high alarm value; 2.press M key again,high warning lighting,press↑or↓to adjust high warning value; 3.press M key again,low warning lighting,press↑or↓to adjust low warning value; 4.press M key,low alarm lighting,press↑or↓to adjust low alarm value *it will be saved automatically in 5 seconds without any setting. *to keep pressing ↑or ↓ adjusts the values quickly. Networking To network the alarms by 485 connectors.for each alarm,it...

 Open the catalog to page 4
Blackfish,hospital gas monitoring,gas alarm,BFZGAE-5

BLACKFISH INDUSTRIES (SHANGHAI) CO.,LTD The terminal in PINK to provide analog output of DC1--5V, corresponding the positive of -0.1MPa to 1.0MPa,vacuum of -0.1MPa to 0MPa. BLACKFISH INDUSTRIES (SHANGHAI) CO.,LTD

 Open the catalog to page 5