Blackfish medical gas manifold,BF-MGM,Automatic
8Pages

{{requestButtons}}

Catalog excerpts

Blackfish medical gas manifold,BF-MGM,Automatic - 1

Automatic Medical Gas Manifold Systems

Open the catalog to page 1
Blackfish medical gas manifold,BF-MGM,Automatic - 2

Summary Medical gas automatic control cabinet is the latest development of our factory series of products, is the core unit of the central air supply station. This series of control system by mechanical pressure difference valve automatic switching control, copper integration structure of dual path design, stable pressure, large flow, automatic switch is flexible and can also be manually, for ward building of secondary voltage box provides steady inlet pressure, direct supply using the terminal. Under the working state, a gas feed, another way for standby, when the way air pressure is...

Open the catalog to page 2
Blackfish medical gas manifold,BF-MGM,Automatic - 3

Schematic diagram of the working principle is as follows: Work state Large flow Large flow

Open the catalog to page 3
Blackfish medical gas manifold,BF-MGM,Automatic - 4

Adjustable regulator Large flow Adjustable regulator Large flow One-way valve One-way flow Large flow One-way valve One-way flow Large flow Pressure gauge The left cylinder pressure indicator Pressure gauge The right cylinder pressure indicator Pressure gauge The left cylinder through the primary pressure Pressure gauge The right cylinder through the primary pressure left road pressure transmitter Monitor the pressure on the left Right road pressure transmitter Monitor the pressure on the right Output pressure transmitter Monitor the pressure output Left input Can connect bus 1 to 10...

Open the catalog to page 4
Blackfish medical gas manifold,BF-MGM,Automatic - 5

Three,Description of the use of various components models and specifications 1. Setting of control panel: ① The length of the set button is 3 seconds, the lower side of the two digital tubes display: ID 0000, indicating the ID code of the control board, and the ID number of the control board can be modified by pressing the "raise" key or "down-regulating" key. ② Continue to press the setting key, the digital tube shows that P n-h 000.0 indicates the alarm value of the outlet pressure limit, and the upper limit alarm value can be modified by pressing the "raise" key or "down-regulation" key....

Open the catalog to page 5
Blackfish medical gas manifold,BF-MGM,Automatic - 6

2、Air gauge instructions: B1-15 and B2-15 respectively indicate bus-bar the left (right) bottle bottle (left), the right pressure, the range of 0 ~ 25 , specifications Φ 60 barometer, accuracy of 2.5;2.5-2.5 - B1 and B2 - instructions on the left, right after the decompression pressure respectively, range 0 ~ 2.5 , specifications Φ 60 barometer, precision with a magnitude of 2.5. 3. Instructions for pressure transmitter: Left and right pressure transmitter pcm300-25 monitoring range 0~ 25Mpa(250bar), input 24VDC, output 0~ 10V.The two pressure transmitters monitor the gas pressure of the...

Open the catalog to page 6
Blackfish medical gas manifold,BF-MGM,Automatic - 7

⑩The upper digital tube and the indicator light indicate the output status;The left digital tube and indicator light indicate the state of the cylinder input;The right digital tube and indicator light indicate the status of the cylinder input (see below:) 8. Control system: Work in automatic state, Mechanical differential pressure valve switching device for automatic switching control。 Four、Gas path system operation instructions 1、See schematic diagram of working principle: (1) 、Automatic operation after connecting cylinders。Can adjust J1-1.6 and J2-1.6 adjust the output pressure to meet...

Open the catalog to page 7
Blackfish medical gas manifold,BF-MGM,Automatic - 8

switch control system, power control D2 D2 D1 make D1 power off, open the left turn left and right air supply; alternate work, Everfount to supply gas to the ward building. Standby gas should be replaced in a timely manner, without spare gas, the alarm will alarm, in the use of gas to replace a good standby gas before the alarm, the alarm is released. Five、Matters needing attention 1、When the pressure gauge pressure value is greater than 1.8Mpa, or the safety valve exhaust, should immediately shut down the road into the gas source, at the same time open the other way gas, and then deal with...

Open the catalog to page 8