Catalog excerpts
smith&nephew II CR Cruciate Retaining Knee System
Open the catalog to page 1Graph 1 2 Percent reporting no difficulty Graph 2 3 Sports activity Control subjects carrying heavy objects golf racquet sports dancing Today’s fastest growing segment of knee replacement patients is seeking a return to a more active lifestyle.1 Traditional knee replacement options don’t meet the need for higher functionality, improved motion or long-term durability.2,3,4,5 Most significantly, these traditional systems fall short in providing a return to a normal pattern of motion. Lack of motion, both selection and kinematics, can mean less satisfaction for patients who are unable to...
Open the catalog to page 2PHYSIOLOGICAL MATCHING™ Technology through function, motion and durability JOURNEY II CR Knee System with PHYSIOLOGICAL MATCHING Conventional TKA For orthopaedic surgeons seeking treatment solutions beyond traditional knee replacements, the JOURNEY™ II Cruciate Retaining Knee has been engineered to empower patients with a renewed right to an active lifestyle by breaking through traditional knee replacement barriers and delivers Function, Motion and Durability through PHYSIOLOGICAL MATCHING Technology
Open the catalog to page 3Function • natomic, articular surfaces are designed to restore A native anatomy and yield a normal anatomic A/P position throughout the range of motion. Lachman test JOURNEY™ TKA patients • Anterior stability is provided by a high posterior medial lip which mimics ACL function in full extension and early gait. Increased stability through proper AP position and reduction in paradoxical motion Mid-line Sulcus • rovides a proper femoro-tibial A/P position yielding a P virtual elimination of paradoxical motion, anterior sliding of the femur during flexion.6-13 Posterior Medial Lip/Horn
Open the catalog to page 4Strength • ore normal muscle firing patterns are expected due M to the proper A/P positioning, thereby helping to prevent muscle fatigue during activities of daily living. • estoration of both the anatomic A/P alignment and the R normal kinematic patterns of the knee should produce more normal neuromuscular firing patterns throughout the range of motion—as demonstrated in the original JOURNEY™ BCS design.10, 15 Satisfaction (Proprioception) • mproving patients’ ease of activities of daily living can I be expected due to the anticipated improvements of strength and stability • estoration of...
Open the catalog to page 5Motion Tibiofemoral (TF) kinematics The kinematic patterns of the femur and tibia of a knee design have a direct impact on patients' reported levels of satisfaction with the outcomes of their knee replacements.’9, 20 Extension • Femur internally rotated to achieve a natural anatomic screw-home position • Minimal posterior femoral overhang in the sagittal plane (Proper A/P position) Mid-flexion • Femur external rotation to maximize quadriceps mechanism efficiency • Virtual elimination of paradoxical motion to prevent mid-flexion instability Deep flexion • Femur remains externally rotated to...
Open the catalog to page 6The kinematic pattern in the PF joint is critically important to decrease anterior knee pain post operatively and the associated revisions.22'23'24'25 • Provides improved contact which should improve wear performance22 • Provides improved patella tracking which should minimize anterior pain 22'23 • Provides more freedom of baseplate positioning without maltracking concerns26 Lateral Patellar Shift (mm) 0 15 30 45 60 75 90 105 120 135Knee Flexion (deg)Flexion The normal kinematic patterns of movement provide the correct environment to allow an anatomic, deep flexion...
Open the catalog to page 7Durability Combining the award-winning materials of OXINIUM™ Oxidized Zirconium and highly cross-linked polyethylene (XLPE), Smith & Nephew was able to create VERILAST™ Technology, a highly urable d and long-lasting material combination.Using this technology, JOURNEY™ II TKA is designed to match the same high standards for wear performance. Graph 3 VERILAST Technology vs Conventional Technology 45 43.40 OXINIUM Technology on XLPE Mean volumetric wear rates (+/- std. dev.) of CoCr against conventional polyethylene (CPE), CoCr against crosslinked polyethylene (XLPE) and OXINIUM against XLPE...
Open the catalog to page 83D surface profiles of Oxidized Zirconium and Cobalt-Chromium femoral components Wear • XINIUM™ Oxidized Zirconium is an advanced bearing O material that combines the strength of metal with the wear resistance of ceramics • OXINIUM Technology is 4,900 times more resistant to abrasion than CoCr 38 • XINIUM Technology is more than twice as hard as O CoCr (Graph 4) 39 Metal Sensitivity e understand that no measurable nickel content is W of immeasurable benefit to nickel-sensitive patients • XINIUM Oxidized Zirconium, exclusively from O Smith & Nephew, addresses the needs of nickelsensitive...
Open the catalog to page 9Innovating for the lifecycle Following on a rich history of partial knee arthroplasty and success of the JOURNEY™ BCS design - which showed recovery of normal patterns of motion and high gains in flexion 6-13, 21 27-28 - Smith & Nephew has created a seamless, next generation family of partial and primary knee designs intended to restore patients’ level of function, motion and durability. 1972 Richards Manufacturing Company Marmor Uni Richards Manufacturing collaborate with Dr. Leonard Marmor to commercially produce the first unicondylar knee on the market. 2006 JOURNEY PFJ -The JOURNEY PFJ...
Open the catalog to page 102009 VISIONAIRE™ Patient Matched Instrumentation In 2009 Smith & Nephew globally launched the foundation of its patient specific solutions, VISIONAIRE Patient Matched Cutting blocks. Smith & Nephew was the first company to launch patient matched technology developed and manufactured completely in house. 2007 PLUS Orthopedics Smith & Nephew purchased the Swiss company PLUS Orthopedics. This added the PLUS SOLUTION knee family to the portfolio: TC-PLUS™ PRIMARY, TC-PLUS REVISION, and RT-PLUS™ REVISION. The PLUS Knee family is developed and manufactured in Switzerland and offers a seamless...
Open the catalog to page 11All Blue Belt Technologies catalogs and technical brochures
-
ZUK Uni
8 Pages
-
JOURNEY II XR Preview
2 Pages
-
JOURNEY PFJ
12 Pages
-
JOURNEY UNI
12 Pages
-
NAVIO Surgical Systems
4 Pages
-
STRIDE Product Brochure
1 Pages
-
STRIDE Surgical Technique
37 Pages
-
STRIDE Unicondylar Knee System
33 Pages
-
Navio Product Brochure
2 Pages
-
Navio Patient Brochure
2 Pages