Catalog excerpts
understanding bioprocesses Real-time gas analysis and software for the management of bioprocessing
Open the catalog to page 1Understanding bioprocesses for more than 15 years The founders and managing directors of BlueSens Dr. Udo Schmale (left) and Dr. Holger Müller (right) BlueSens was founded 2001 in Germany and develops and manufactures analyzers and software for bioprocess applications. In 2015 the BlueSens Corporation was founded in Illinois. The motivation of BlueSens is to provide instruments and software so that their customers gain comprehensive understanding of their bioprocesses to get a maximum optimized process for maximum yield at maximum quality. To achieve that, BlueSens is offering a variety of...
Open the catalog to page 2BlueVary: Maintenance free & flexible Key facts BlueVary Maintenance free No need for annual maintenance. Performing our established one-point calibration regularly is all you have to do. No specific training – easy to install and handle Install and calibrate it yourself. PC housing and various connections guarantee easy handling. EtOH Maximum flexibility Combine two gases for parallel measuring (CO2, O2, H2, CH4, EtOH). Use it also for biogas applications. MORE INFORMATION: BLUEVARY.BLUESENS.COM The basis station with three plug-in positions and an integrated data display operated by...
Open the catalog to page 3BlueInOne: Combined CO2/O2 sensor One device for the parallel measurement O2 and CO2, humidity and pressure. No minimal gas flow needed. Fluctuating pressure/humidity are autocompensated. Safe time and money The reasonably priced BlueInOne helps you to understand your process in real-time to save time. Perfect gas analyzer for microbial processes One analyzer per process means continuous real-time measurement without interruptions. MORE INFORMATION: BLUEINONE.BLUESENS.COM Biomass Growth rate µmax, Xs, Yxs
Open the catalog to page 4BlueVCount: Volumetric flow-measurement Key facts BlueVCount More process information Leads to less number of experiments and optimized yields. Less maintenance No water or oil refill necessary. Auto compensation Shows standard volume because of integrated °C pressure and temperature compensation. MORE INFORMATION: BLUEVCOUNT.BLUESENS.COM
Open the catalog to page 5Yieldmaster: Gold Standard of BMP test systems Key facts Yieldmaster Modular Bio-Methane Potential (BMP) evaluation system Microprocessor controlled infrared-gas sensors, precision volumetric flow-meters BlueVCount and BlueVIS software. No gas treatment/filtering needed The analyzers might either be positioned directly at the headspace or in the off-gas line of any fermenter. EtOH Bio-Methane Potential Maximum flexibility Detection of other important gases besides CH4 possible. MORE INFORMATION: YIELDMASTER.BLUESENS.COM
Open the catalog to page 6BCpreFerm: OUR, CER, RQ for shake flasks Key facts BCpreFerm System for process optimization Designed for scale up from flasks up to large-scale fermenters. up to Up to 12 gas sensors The gas sensors monitor vital parameters both on fermenters as well as on flasks. No limitations Dedicated process optimization without limitations (e.g. oxygen, nutrients etc.) MORE INFORMATION: BCPREFERM.BLUESENS.COM BCP sensors: Easy in-situ analysis Key facts BCP sensors EtOH MORE INFORMATION: BCP.BLUESENS.COM Wide choice Each sensor is for a single gas: H2, CO2, CO, Ethanol, O2, CH4. Different housing All...
Open the catalog to page 7lull □ill Fermenter Custom 0 Configuration © Service Q Help Custom Groups Key facts BlueVIS software Parallel tracking of important process parameters Monitoring, acquisition and integration of data from all components and for process control in real-time. Digital and anlog data input implemented Analog devices can be connected via analog/digital converter. Open to other systems and brands Integrated OPC server/client for data exchange to other systems and programs. BlueVIS Calculates OUR, CER, RQ, growth rate and biomass*, offers math sensors and connects to MATLAB. * by EXPUTEC®soft...
Open the catalog to page 8• Re-use equipment you already have. • Or use BlueVIS to set-up your own bioprocessing system. • You don’t have equipment yet? Ask us for a complete pre-assembled system.
Open the catalog to page 9* = full scale ** = also available as cartridge for BlueVary 1 = accuracy < ± .0.5 % FS* ± 5% reading 2 = with monthly 1-point calibration 3 = not compensated 4 = Ethernet with BACCom 5 = stainless steel housing, dimensions depends on flow adapter 6 = others on request 7 = binary mixture
Open the catalog to page 10* = full scale ** = also available as cartridge for BlueVary 1 = accuracy < ± .0.5 % FS* ± 5% reading 2 = with monthly 1-point calibration 3 = not compensated 4 = Ethernet with BACCom 5 = stainless steel housing, dimensions depends on flow adapter 6 = others on request 7 = binary mixture
Open the catalog to page 11BlueSens gas sensor GmbH • Snirgelskamp 25 • 45699 Herten • Germany Phone: +49 2366 4995-500 • Fax: +49 2366 4995-599 • E-mail: info@BlueSens.de
Open the catalog to page 12All BlueSens gas sensor GmbH catalogs and technical brochures
-
BCpreFerm
5 Pages
-
BCP-O2
2 Pages
-
BCP-H2
2 Pages
-
BCP-CO2
2 Pages
-
CO2 in-situ measurement
8 Pages
-
BCP - CH4
2 Pages
-
BCP-CH4 Brochure
6 Pages
-
BlueInOne Brochure
12 Pages
-
BlueVary Brochure
8 Pages