Catalog excerpts
Adjustment Method of Oxygen Concentration Flow Monitoring Flow Rate Oxygen Concentration Adjustment Range ★Temperature Output Range ★Temperature Adjustment Gear Whether the host is disinfection-free Screen Size Trend Review Function Oxygen Concentration Monitoring Temperature Monitoring ★sPEEP Monitoring ★ Respiratory Rate Monitoring Automatic filter replacement function Automatic water refill tips ★AutoFlow ★SmartFlow Humidity Compensation ★sPEEP ★ Hot Standby H-80AS Auto Monitorable, Adjustable 2L ~ 80L/min 21% ~ 100% 29 C ~ 37 C 9 steps adjustable Yes 3.5 inches 1 day; 3 days; 7 days Monitorable, Adjustable Monitorable, Adjustable Monitorable Monitorable Yes, can be set Yes Yes Yes -3~+3, 7 steps adjustable 0~4 steps adjustable Yes Auto Monitorable, Adjustable 2L ~ 80L/min 21% ~ 100% 29 C ~ 37 C 9 steps adjustable Yes 3.5 inches 1 day; 3 days; 7 days Monitorable, Adjustable Monitorable, Adjustable Monitorable Monitorable Yes, can be set Yes / / -3~+3, 7 steps adjustable / Yes Manual Monitorable, Adjustable 2L ~ 80L/min 21% ~ 100% 29 C ~ 37 C 9 steps adjustable Yes 3.5 inches 1 day; 3 days; 7 days Monitorable Monitorable, Adjustable Monitorable Monitorable Yes, can be set Yes / / -3~+3, 7 steps adjustable / Yes H-80 Series HighProvide more better oxygen therapy with FlowHigh Flow BMC Medical Co., Ltd. Room 110, Tower A Fengyu Building, No.115 Fucheng Road, Haidian, 100036 Beijing, PEOPLE,S REPUBLIC OF CHINA Tel: +86-10-5166 3880 Fax: +86-10-5166 3880 ext. 810 ST-SC-20-02-04-03-004-Ver1.1 en.bmc-medical.com
Open the catalog to page 1H-80 Series BMC new H-80 Series high-flow oxygen therapy, highly integrated design, to meet more needs of clinical treatment • provide a maximum of 80L / min air-oxygen mixed gas, oxygen concentration can be set automatically, providing an exclusive patent AutoFlow function, SmartFlow function. • Disinfection-free design, Water chamber has a backflow prevention valve to prevent gas backflow, and overall maintenance is more convenient. H-80 Series High Flow Oxygen Therapy, can be used for patients with spontaneous breathing, including artificial airway respiratory insufficiency, and can be...
Open the catalog to page 2All BMC Medical Co. catalogs and technical brochures
-
Hospital Product Catalogue
20 Pages
-
HT series HFNC
4 Pages
-
Nasal Cannula NC12
2 Pages
-
Nasal Cannula NC11
2 Pages
-
Breathing Tube L1
2 Pages
-
Polypro H2 series
2 Pages
-
PolyWatch YH-600
2 Pages
-
H-80 series H-80M
4 Pages
-
H-80 series H-80A
4 Pages
-
CMS50DL
4 Pages
-
R series Ventilator
4 Pages
-
M1 Mini Auto CPAP Device
8 Pages
-
BMC Product Catalog
21 Pages
-
BMC F2NV Full Face Mask
2 Pages
-
BMC N5B Nasal Mask
2 Pages
-
BMC N5A Nasal Mask
2 Pages
-
BMC N5 Nasal Mask
2 Pages
-
BMC NM4 Nasal Mask
2 Pages
-
BMC NM2 Nasal Mask
2 Pages
-
BMC F5A Full Face Mask
2 Pages
-
BMC F5 Full Face Mask
2 Pages
-
BMC F4 Full Face Mask
2 Pages
-
BMC F1B Full Face Mask
2 Pages
-
BMC FM1A Full Face Mask
2 Pages
-
BMC HME Series Mask
4 Pages
-
BMC F2 Full Face Mask
2 Pages
-
BMC F3 Full Face Mask
2 Pages
-
BMC 5 series Masks
8 Pages