HammerLock®
1 / 2Pages

Catalog excerpts

HammerLock® - 1

* ALL SIZES IN MILLIMETERS DESCRIBING IMPLANTS IN ACTIVATED STATES. * X-RAY TEMPLATE A117-006 MAY BE USED TO DETERMINE IMPLANT SIZE. CANAL PREPARATION GUIDELINES SIZE PROXIMAL DRILL DEPTH DISTAL DRILL DEPTH PROXIMAL BROACH DISTAL BROACH 3/4 length of cutting flutes minimum 1/4 length of cutting flutes minimum 3/4 length of cutting flutes minimum 1/4 length of cutting flutes minimum 3/4 length of cutting flutes minimum 1/4 length of cutting flutes minimum 1/2 length of cutting flutes minimum 1/4 length of cutting flutes minimum 1/2 length of cutting flutes minimum 1/4 length of cutting flutes minimum 1. ALTHOUGH THE S-240QD (2.4MM) DRILL BIT IS GENERALLY RECOMMENDED, VARYING ANATOMIES MAY REQUIRE THE USE OF THE SMALLER S-200QD (2.0MM). ADDITIONAL RESISTANCE MAY BE FELT DURING INSERTION. 2. WHEN USED FOR DIP FUSIONS OF THE LESSER TOES, THE PETITE AND DIP IMPLANTS MAY BE REVERSED BY INSERTING THE EXPOSED END OF THE IMPLANT INTO THE DISTAL PHALANX. Continuous Active Compression Implant for the Lesser Toes • Actively adjusts to canal width • Uniquely designed fixation barbs maintain compression while minimizing stress on cortical walls • Straight and angled implants to meet most clinical requirements 14785 Omicron Drive Suite 205 San Antonio, TX 78245 www.bme-tx.com FDA CLEARED. CE MARKED. PATENTS: WWW.BME-TX.COM/PATENTS Toll Free Fax Corporate Email • Large range of anatomic sizes to accommodate virtually all patient sizes BME has been certified by BSI to ISO 13485 under the certificate number FM602278 ©2014 BioMedical Enterprises, Inc. All rights reserved. HAMMERLOCK is a trademark of BioMedical Enterprises, Inc. • Patent-pending insertion system for fast, precise implantation • Squeeze Tab Retention System for quicker implantation • Linear body design for enhanced fusion interface HAMMERLOCK HAMMERLOCK® HAMMERLOCK® SIZES

Open the catalog to page 1
HammerLock® - 2

After site preparation and resections, prepare the medullary canals by drilling into each canal with the recommended drill bit (see Canal Preparation Guidelines chart below). If necessary, the reamer may be used to resect the articular cartilage. Open the Forceps to expose the distal end of the implant. While flexing/ distracting the joint, insert the distal end of the implant into the distal fragment until contact is made with the Tab. NOTE: Halsted Forceps (supplied) may be used to pinch the distal arms of the implant together prior to reduction. Without rotating, broach into each canal...

Open the catalog to page 2

All BME - BioMedical Enterprises catalogs and technical brochures

  1. speed triad

    2 Pages

  2. BME Elite®

    4 Pages

  3. Matrix OI®

    4 Pages

  4. Speed Shift

    2 Pages

  5. Speed Arc

    2 Pages

  6. SPEED

    2 Pages

Archived catalogs