INCUCELL/INCUCELLV - 1

INCUCELL® / INCUCELL® V Incubators with Natural / Forced Air Convection Suitable for safe treatment of microbiological cultures. The INCUCELL® line produces no noise and provides a very soft air convection within the chamber, the variant INCUCELL® V (with a fan) has an advantage of more precise temperature distribution with small deviations. These devices can be used especially in biological and microbiological laboratories, quality tests in pharmacy, cosmetics and testing in veterinary medicine and food processing industry. Laboratory incubators Volume: 22, 55, 111, 222, 404, 707 litres Working temperature: INCUCELL®: 5°C above ambient temperature up to 99.9°C INCUCELL® V: 10°C above ambient temperature up to 99.9°C Inner glass door Interior: stainless steel, mat. No. 1.4301 (AISI 304) The Versatile Standard Line with Microprocessor Control Unit • 3 adjustable programs • RS 232 – interface for printer or PC-communication • delayed heating start and stop function • acoustic and visual alarm in error state • time range 99 hours 59 minutes • digital safety thermostat • manual control of the air exhaust flap (the suction and air exhaust only INCUCELL® V, the air exhaust only INCUCELL®) • access ports ∅ 25, 50, 100 mm (∅ 50, 100 mm is not available for 22 liters volume) • door lock • left door versions (excluded volume 22 and 707 litres) • HEPA filter for installation in an air inlet (INCUCELL® V only) • arrangement against drying-up of culture mediums and tissue cultures (INCUCELL® V only) • adjustable ventilation rate 50–100% (only INCUCELL® V) • special software WarmComm 4.0 • separate PT 100 sensor • stainless steel casing of the devices The High-Tech Comfort Line with Multi-Functional Microprocessor Control Unit • 6 adjustable programs • chip card system for individual program storage • RS 232 – interface for printer or PC-communication • delayed heating start and stop function • acoustic and visual alarm in error state • time range 0–40 years with 1 min-intervals • digital safety thermostat • real time • selectable rate of temperature increase or decrease – “RAMPS” • programming of program time segments – “SEGMENTS” • programme cycles • adjustable ventilation rate 10 to 100% • manual control of the air exhaust flap (the suction and air exhaust only INCUCELL® V) • keyboard blocking • door opening control • access ports ∅ 25, 50, 100 mm (∅ 50, 100 mm is not available for 22-liters volume) • door lock • left door versions (excluded volume 22 and 707 litres) • HEPA-filter for installation in air inlet (INCUCELL® V only) • timer programmable water protected inner socket • arrangement against drying-up of culture mediums and tissue cultures • high temperature decontamination (INCUCELL® V only excluded volume 404 and 707 litres) • BMS relay alarm co

Open the catalog to page 1
INCUCELL/INCUCELLV - 2

INCUCELL® / INCUCELL® V C€ Note: All technical data are related to 22°C ambient temperature and ± 10% voltage swing (if not specified). *) Approx. 50% of the tray area can be filled in a way a uniform air circulation is enabled inside the chamber. **) Supply voltage is indicated on the type lable of the unit. ***) Temperature deviations were measured in accordance with DIN 12 880, section 2 The values may differ depending on specific charge and media parameters. Changes in the design and make reserved. INCUCELL/INCUCELL V_01/2017_EN/PR ® Photo & design T. Benda MMM Medcenter...

Open the catalog to page 2

All BMT Medical Technology catalogs and technical brochures

  1. VACUCELL

    2 Pages

  2. FRIOCELL

    2 Pages

  3. CLIMACELL

    2 Pages

  4. CO2CELL

    2 Pages

  5. STERILAB

    5 Pages

  6. UNISTERI HP IL

    11 Pages

  7. UNISTERI HP

    9 Pages

  8. STERIVAP HP

    7 Pages

  9. STERIVAP

    7 Pages