Group: BodyCAP
Catalog excerpts
eCelsius Performance brochure ® A system for a reliable and accurate temperature monitoring Scientifically validated Gold standard for temperature monitoring
Open the catalog to page 1Current human field applications About eCelsius Performance added value slide 4 eCelsius Performance specifications Examples of research study
Open the catalog to page 2Current human field applications
Open the catalog to page 3Current human field applications Few examples Core temperature monitoring is a primary or secondary outcomes in many scientific applications: Circadian rhythm monitoring Chronobiology and Sleep research Thermoregulation research Infectiology Oncology Drug/vaccine development
Open the catalog to page 4About eCelsius Performance ®
Open the catalog to page 5Introduction eCelsius ® Performance: the essentials RF 433Mhz eViewer Performance monitor eCelsius Performance pill ePerformance Manager software Activation box to turn on the pilll Communication range in real time : from 1 to 3 m (subject & environment depending)
Open the catalog to page 6About eCelsius Performance ® Minimum weight 40kg Few parameters may impact the performance of the system The subject morphology The environment (metal,...) Depending on the combination of these parameters, the number of We can advise & monitor required will differ.help you define the best configuration for your study.
Open the catalog to page 7eCelsius Performance added value ® Technical specifications: Scientific advantages: NO DATA LOSS No data loss even if the subject is out of the communication range for a while. PILL INTERNAL MEMORY Embedded memory in the pill allows to continuously store the last 2000 collected data independently of the life duration. MEASUREMENT PERIOD Several sampling frequency are available and changed all along the monitoring. REAL TIME & A POSTERIORI DATA RECOVERY If the monitor is in the communication range of the pill, you can collect real time data. If not the monitor will synchronize the missing...
Open the catalog to page 8Example of research studies
Open the catalog to page 9seiduts hcraeser fo elpmaxE Clinical trials in oncology eCelsius Performance ADDED VALUE PATIENT IN ONCOLOGY HEMATOLOGY Continuous monitoring without any constraints for subjects and operator Save time allocated to data collection Enhance monitoring accuracy Limit human mistakes This ongoing clinical trial allows to demonstrate that a proper and continuous core temperature monitoring is able to reduce the delay for treatment initiation. Clinical trial in progress Physician: Pr Fabrice Jardin PUPH Center: Hemathology Department - Centre UNICANCER - H. BecquerelRouen (France)
Open the catalog to page 10Example of research studies Clinical trials in infectiology eCelsius Performance ADDED VALUE PATIENT IN INFECTIOLOGY Limit the contact with infectious people Save time allocated to data collection Enhance monitoring accuracy Limit human mistakes To preserve patient comfort, the medical staff does not collect the temperature during the night. This ongoing clinical trial allows to demonstrate the interest for a proper and continuous core temperature monitoring to detect inappropriate night events. Physician: Pr Philippe Brouqui - PUPH Center: UHI Méditerranée - AP - HM Marseille (France)...
Open the catalog to page 11Example of research studies Clinical trials in sleep/chronobiology eCelsius Performance ADDED VALUE Circadian rhythmicity of gastrointestinal temperature Individual core temperature rhythm collection Preservation of comfort and mobility Enhance monitoring accuracy Limit human mistakes The core temperature is a key indicator of the biological rhythmicity of the subjects. Continuous monitoring of this variable allows to characterize the circadian rhythm of the core temperature, which is an essential tool for sleep analysis and the diagnosis of sleep disorders. Publication: Komarzynski et al.,...
Open the catalog to page 12Reach Out to Us Email address contact@bodycap-medical.com Mailing address BodyCAP 3 rue du Docteur Laennec 14200 Hérouville Saint-Clair FRANCE Follow us on social media Copyright © - 2020 BodyCAP - Your e-health partner
Open the catalog to page 13All BodyCAP catalogs and technical brochures
-
Cooling vest
1 Pages
-
Anipill
17 Pages
-
eTact
10 Pages