1. Catalogs
  2. BodyCAP
  3. eCelsius Medical system Brochure

eCelsius Medical system Brochure
1 /13Pages

eCelsius Medical system Brochure

eCelsius Medical system Brochure
1 /13Pages

Catalog excerpts

eCelsius Medical system Brochure-1

eCelsius Medical brochureA system for reliable and accurate core body temperature monitoring Solution FDA cleared (N° K210924) P072BRO001 - eCelsius Medical system Brochure.1 - EN

 Open the catalog to page 1
eCelsius Medical system Brochure-2

Current medical applications eCelsius Medical added value About eCelsius Medical Examples of medical applications P072BRO001 - eCelsius Medical system Brochure.1 - EN

 Open the catalog to page 2
eCelsius Medical system Brochure-3

Current medical applications P072BRO001 - eCelsius Medical system Brochure.1 - EN

 Open the catalog to page 3
eCelsius Medical system Brochure-4

Current medical applicationsFew examplesCore body temperature monitoring is a key parameter for many medical applications: • Oncology care • Infectious diseases • Sleep disorders • Chronobiology and circadian rhythm monitoring • Drug/vaccine development P072BRO001 -eCelsius Medical system Brochure.1 - EN

 Open the catalog to page 4
eCelsius Medical system Brochure-5

About eCelsius Medical P072BRO001 - eCelsius Medical system Brochure.1 - EN

 Open the catalog to page 5
eCelsius Medical system Brochure-6

eViewer Medical monitor eCelsius Medical capsule eCelsius Manager software Activation box to turn on the capsule Communication range in real time: around 1m (patient & environment depending) P072BRO001 - eCelsius Medical system Brochure.1 - EN

 Open the catalog to page 6
eCelsius Medical system Brochure-7

eCelsius Medical CAPSULE SPECIFICATIONS eCelsius Medical ACTIVATOR SPECIFICATIONS: to turn on the capsule eViewer Medical MONITOR SPECIFICATIONS: to visualize and record the data Few parameters may impact the communication range of the system: We can advise & help you define the best configuration for your uses. P072BRO001 - eCelsius Medical system Brochure.1 - EN

 Open the catalog to page 7
eCelsius Medical system Brochure-8

eCelsius Medical added value Technical specifications: Medical advantages: NO DATA LOSS No data loss even if the patient is out of the communication range for a while. CAPSULE INTERNAL MEMORY Embedded memory in the capsule allows to continuously store the last 2000 collected data in FIFO mode. REAL TIME & A POSTERIORI DATA RECOVERY If the monitor is in the communication range of the capsule, you can collect real time data. If not, the monitor will synchronize the missing data as soon as the capsule and the monitor are back in their communication range. TIME SAVER After activation and ingestion,...

 Open the catalog to page 8
eCelsius Medical system Brochure-9

Example of medical applications P072BRO001 - eCelsius Medical system Brochure.1 - EN

 Open the catalog to page 9
eCelsius Medical system Brochure-10

Example of medical applications Clinical trials in oncology eCelsius Medical ADDED VALUE 1 Continuous monitoring without any constraints for patients and operator Save time allocated to data collection Enhance monitoring accuracy Limit human mistakes PATIENT IN ONCOLOGY HEMATOLOGY This clinical trial allows to demonstrate that a proper and continuous core temperature monitoring is able to reduce the delay for treatment initiation. Physician: Pr Fabrice Jardin PUPH Center: Hemathology Department - Centre UNICANCER - H. Becquerel- Rouen (France) P072BRO001 - eCelsius Medical system Brochure.1 -...

 Open the catalog to page 10
eCelsius Medical system Brochure-11

eCelsius Medical ADDED VALUE Limit the contact with infected patient Save time allocated to data collection Enhance monitoring accuracy Limit human mistakes To preserve patient comfort, the medical staff does not collect the temperature during the night. This clinical trial allows to demonstrate the interest for a proper and continuous core temperature monitoring to detect inappropriate night events. Huang et al., (2019), Ingestible sensors correlate closely with peripheral temperature measurements in febrile patients. Patient Infectiology threshold for medical decision Physician: Pr Philippe...

 Open the catalog to page 11
eCelsius Medical system Brochure-12

Example of medical applications Clinical trials in sleep / chronobiology eCelsius Medical ADDED VALUE Circadian rhythmicity of gastrointestinal temperature Individual core temperature rhythm collection Preservation of comfort and mobility Enhance monitoring accuracy Limit human mistakes The core body temperature is a key indicator of the biological rhythmicity of the patients. Continuous monitoring of this variable allows to characterize the circadian rhythm of the core body temperature, which is an essential tool for sleep analysis and the diagnosis of sleep disorders. Publications: Komarzynski...

 Open the catalog to page 12
eCelsius Medical system Brochure-13

Reach Out to Us Email address [email protected] Mailing address BodyCAP 3 rue du Docteur Laennec 14200 Hérouville Saint-Clair FRANCE Follow us on social media Copyright © - 2024 BodyCAP - Your e-health partner All rights reserved P072BRO001 - eCelsius Medical system Brochure.1 - EN

 Open the catalog to page 13

All BodyCAP catalogs and technical brochures

  1. Cooling vest

    1  Page

  2. Anipill

    17  Pages

  3. eTact

    10  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.