eCelsius Performance Connect brochure A system for a reliable and accurate temperature monitoring Scientifically approved Gold standard for core temperature monitoring
Open the catalog to page 1Current human field of applications eCelsius Performance Connect specifications eCelsius Performance Connect added value Examples of research study
Open the catalog to page 2Current human fields of application
Open the catalog to page 3Current human fields of application Few examples Core temperature monitoring is a primary or secondary outcomes in many scientific research applications: • Circadian rhythm monitoring • Chronobiology and Sleep research • Thermoregulation research • Infectiology research protocols • Oncology research protocols • Drug/vaccine development research prot
Open the catalog to page 4About eCelsius Performance Connect
Open the catalog to page 5Introduction eCelsius Performance Connect: the essentials eCelsius Performance capsule Activation box to turn on the capsule 05 Communication range between capsule and ePerf Connect in real time : 1 to 3m (depending on subject & environment)
Open the catalog to page 6About eCelsius Performance Connect Specifications eCelsius Performance CAPSULE SPECIFICATION Capsule cleaning Size (Diameter x lenght) Temperature accuracy Temperature resolution Life duration Shef life Measurement period available Temperature range Standardized cleaning process eCelsius Perf ACTIVATOR SPECIFICATION: to turn on the capsule 69mm x 59mm x 31mm Able to activate a large number of pills ePerf Connect SPECIFICATION: to collect and record data For Android Smartphone/Tablet (available on Google Play Store) Weight Storage Number of capsule associated e-Perf Mobile App: To configure the...
Open the catalog to page 7eCelsius Performance Connect added value Technical specifications: Scientific advantages: NO DATA LOSS No data loss even if the subject is out of the communication range for a while. CAPSULE INTERNAL MEMORY Embedded memory in the capsule allows to continuously store the last 2000 collected data independently of the life duration. REAL TIME & A POSTERIORI DATA RECOVERY MEASUREMENT PERIOD ADAPTABLE MONITORING Several sampling frequency are available and changed all along the monitoring. If ePerf Connect is in the communication range of the capsule, you can collect real time data. If not, ePerf...
Open the catalog to page 8Examples of research studies
Open the catalog to page 9PATIENT IN ONCOLOGY HEMATOLOGY eCelsius Performance Connect ADDED VALUE 1 Continuous monitoring without any constraints for subjects and operator Save time allocated to data collection Enhance monitoring accuracy Limit human mistakes This ongoing clinical trial allows to demonstrate that a proper and continuous core temperature monitoring is able to reduce the delay for treatment initiation. Physician: Pr Fabrice Jardin PUPH Clinical trial in progress Entity: Hematology Department - Centre UNICANCER H. Becquerel- Rouen (France)
Open the catalog to page 10eCelsius Performance Connect ADDED VALUE Limit the contact with infectious people Save time allocated to data collection Enhance monitoring accuracy Limit human mistakes To preserve patient comfort, the medical staff does not collect the temperature during the night. This ongoing clinical trial allows to demonstrate the interest for a proper and continuous core temperature monitoring to detect inappropriate night events. Publication: Huang et al., (2019), Ingestible sensors correlate closely with peripheral temperature measurements in febrile patients. Physician: Pr Philippe Brouqui - PUPH Center:...
Open the catalog to page 11eCelsius Performance Connect ADDED VALUE Circadian rhythmicity of gastrointestinal temperature Individual core temperature rhythm collection Preservation of comfort and mobility Enhance monitoring accuracy Limit human mistakes The core temperature is a key indicator of the biological rhythmicity of the subjects. Continuous monitoring of this variable allows to characterize the circadian rhythm of the core temperature, which is an essential tool for sleep analysis and the diagnosis of sleep disorders. Publication: Komarzynski et al., (2019), Predictability of individual circadian phase during...
Open the catalog to page 12eCelsius Performance Connect ADDED VALUE Individual core temperature collection Preservation of comfort and mobility Enhance monitoring accuracy Limit human mistakes Publication: Moussalem et al., (2021), Effect of Phase Change Material Cooling Vests on Body Thermoregulation and Thermal Comfort of Patients With Paraplegia A Human Subject Experimental Study. Qu et al., (2020), Targeted temperature management at 33 degrees Celsius in patients with high-grade aneurysmal subarachnoid hemorrhage a protocol for a multicenter randomized controlled study. Zucarelli et al, (2020), Obese patients decrease...