Overview
The JFD V Freeze Fracture System by Boeckeler Instruments is a high vacuum cryogenic system designed for producing metal replicas of cryofixed and fractured specimens. It features an elegant design that simplifies operation and ensures repeatable results.
Key Features
  • Equipped with electron guns allowing for 30 or more evaporations between maintenance.
  • Specimens and knives are transferred using an eccentric rod for easy attachment.
  • Shadowing angles can be set rapidly and precisely, with tilting available during the shadowing process.
  • System is user-friendly, allowing unskilled operators to perform experiments with ease.
  • Offers clean, versatile replication with a comfortable, flexible, and reliable design.
Technical Specifications
  • Ultra high vacuum turbopumped chamber with a large viewing window.
  • Vacuum load lock system for sample loading and knife changing.
  • Electron beam guns are housed in a separate high vacuum chamber.
  • LN2 cooled anti-contamination shield surrounds the specimen.
  • Precise temperature control of the Liquid Nitrogen cooled specimen stage with independent digital displays for specimen and knife holder temperatures.
Operational Details
  • The system processes ultra-rapidly frozen samples into high-quality replicas in minutes.
  • Samples are loaded, fractured, etched, shadow cast with platinum, and stabilized with carbon at a rate of 4 to 5 samples per hour.
  • Operates at temperatures down to -170°C with a motor-driven rotating specimen holder for shadowing.
  • Features a self-contained 1-liter LN2 Dewar for rapid cooldown.
Applications
Ideal for high-resolution electron microscopy applications, such as freeze-fracture replica immunogold labeling, with protection from contamination provided by LN2 cooled shields and a high-speed turbo molecular pump.
Additional Features
  • Electron beam guns for evaporating films are in an independent chamber, allowing material changes without breaking the main chamber vacuum.
  • The main sample vacuum chamber is illuminated with an internal LED system and includes a 10x binocular microscope for specimen viewing.
See more

Catalog excerpts

Jeol JFD-V-1

JEOL JFD VFreeze Fracture System cJEOL. Freeze Fracture Equipment Elegant Design Simplifies Operation and Delivers Repeatable Results ^ Ultra high vacuum Turbopumped chamber with large viewing window ^ Vacuum load lock system for sample loading and knife changing ^ Electron Beam Guns load locked in separate high vacuum chamber ^ 'Light tight' LN2 cooled anti contamination shield surrounding specimen FEATURES ♦ Equipped with electron guns ♦ Enjoy 30 or more evaporations between gun maintenance ♦ Specimens and knife transferred by means of an eccentric rod that simply screws into the knife or specimen table ♦ Set shadowing angles rapidly and precisely ♦ Tilting always available, even during shadowing process ("DARS" Process -Double Axis Rotary Shadowing) ♦ System allows unskilled operators to carry out experiments with ease ♦ Clean, versatile replication ^ Precise temperature control of Liquid Nitrogen cooled specimen stage with independent digital display of specimen holder temperature ♦ Comfortable, flexible, reliable <>■ Digital display of knife holder temperature ^ Easy to maintain, easy to clean system 4650 S. Butterfield Drive • Tucson, Arizona 85714 USA Fax: 520.745.0004 • E-mail: [email protected] • www.rmcboeckeler.com © 2015 Boeckeler Instruments, Inc. Boeckeler is a registered trademark of Boeckeler Instruments, Inc., Tucson, Arizona. All other trademarks are the property of their respective owners. All specifications subject to change without notice.

 Open the catalog to page 1
Jeol JFD-V-2

The JFDV Freeze Fracture Instrument is a stand-alone, fully integrated, high vacuum cryogenic system for the production of metal replicas of cryofixed & fractured specimens. Complete with unique vacuum load lock sample insertion holder, the JFD V processes ultra rapidly frozen samples into high quality replicas in just a matter of minutes. The same vacuum load lock system is utilized for changing microtome blades without interfering with the main chamber vacuum. Samples are loaded, inserted, fractured (microtomed or ruptured with double replica device), etched, shadow cast with evaporated platinum...

 Open the catalog to page 2

All Boeckeler Instruments, Inc. catalogs and technical brochures

  1. PTPCZ

    5  Pages

  2. ASH2

    2  Pages

  3. HPM 010

    2  Pages

  4. GKM-2 3-fold

    2  Pages

  5. GKM-2

    2  Pages

  6. FS-8500

    2  Pages

  7. EMP-5160

    2  Pages

  8. CR-X Ultracut

    2  Pages

  9. CR-X

    2  Pages

  10. ASH-100

    2  Pages

  11. AFM-990 Cryo

    2  Pages

  12. AFM-990

    2  Pages

  13. 60617-SR

    2  Pages

  14. MT-990

    2  Pages

  15. MR2, MR3

    2  Pages

  16. Matsci-B2

    2  Pages

  17. Matsci-B1

    2  Pages

  18. HPM Live Mu

    2  Pages

  19. QG-3100

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.