Specifications:
The Boreasa C65S1-12PR-0B-Lx is a miniature centrifugal blower designed with medical-grade thermoplastics. It features a three-phase brushless motor with a Hall sensor and requires a driver for operation. The blower's dimensions are 65.5 x 63 x 48 mm, and it weighs 235 grams. It operates within a temperature range of -20 to +50°C and has a lead wire length of 285 mm. The connector used is MOLEX 43025-1000.
Performance and Testing Conditions:
Performance data was obtained using a Boreasa test chamber at 20°C and sea level with a Boreasa D30/5/4Q-E2 driver. Performance may vary under different conditions or with other drivers. The blower's performance as a vacuum may be less than specified, depending on the operating point.
Technical Data:
The blower operates at a nominal voltage of 12 VDC, with a voltage range of 9 to 14 VDC. It has different performance metrics at zero flow, working point, and free flow conditions, with varying pressure, current, speed, and power consumption. The blower's resistance and inductance are specified, and it has a lifespan of over 30,000 hours at 25°C. The acoustic emission level is below 52.5 dB(A).
Environmental Conditions:
The blower can be stored at temperatures between -20 to +80°C and operates in ambient temperatures of -20 to +50°C with relative humidity between 10 to 85% (non-condensing).
Blower Limits and Warnings:
The blower should not be hot-swapped, and the maximum continuous speed is 52,000 rpm. Blocking the impeller for more than 20 seconds can damage the blower. A minimum airflow is required at voltages higher than nominal to prevent overheating.
Manufacturing and Quality Assurance:
The blowers are manufactured by an ISO9001-2015 certified manufacturer. The internal temperature of the motor is monitored by a 10 KΩ NTC thermistor.
Electrical Connections:
The blower has specific pin connections for motor windings, Hall sensors, and NTC, with wire gauges specified for each connection.
See more

Catalog excerpts

C65S1-0B-1

E-mail: [email protected], URL: www.boreasa.com Miniature Centrifugal Blower * Housing / Impeller Materials: Medical Grade Thermoplastics * Three Phase Brushless Motor w/ Hall Sensor * Standard Motor Internal Temperature Signal * Note: This blower uses a brushless motor and needs a driver to operate Note: - Performances are dependent on the driver used and the test conditions. The data in this spec. sheet was obtained using Boreasa test chamber at 20°C (±2°C) and sea level, and using a Boreasa D30/5/4Q-E2 driver. It may be different than data measured in other conditions or with other drivers. - When used as a vacuum, the blower performance might be less than shown herein, depending on the operating point. - Specifications are subject to change without notice. - Boreasa blowers have been designed and are manufactured to meet the medical device industry requirements. However, it is not possible to test blowers in all conceivable customer application configurations. Consequently, to be used in life support equipment, blowers must be life tested and validated by customers, in their actual application conditions, in a statistically meaningful quantity.

 Open the catalog to page 1
C65S1-0B-2

E-mail: [email protected], URL: www.boreasa.com #1 At given working points and cycle. #2 Measured at distance of 1 meter from inlet, with open inlet, outlet connected to breathing tube and 4 mm orifice in sound chamber at 10 cmH2O. N ote : - Working point is an example close to 50% of max. flow. - The phase inductance and impedance are measured by LCR at 1 kHz, including the connector. - Tolerances based on specified speed data according to ISO 13348, grade 4: pressure ±10%, power ±16%, speed ±5% and flow rate ±5%.

 Open the catalog to page 2
C65S1-0B-3

E-mail: [email protected], URL: www.boreasa.com Electrical Connections Rear side view shown (Mating connector side) Description Motorwinding U Motorwinding V Motorwinding W Hall sensor A Hall sensor B Hall sensor C VHall 5 ... 24 VDC GND NTC NTC Wire Brown Blower Limits and Warning Manufacturing System Motor Internal Temperature Signal (IT) * Blocking the impeller more than 20 seconds may result in damages or destruction of the blower. * A minimum air flow is required at VCc higher than Nominal Voltage to avoid the air in the blower to overheat by compressing and mixing. Blowers manufactured...

 Open the catalog to page 3

All Boreasa Technologies Co., Ltd catalogs and technical brochures

  1. D30/5/4Q-M2

    4  Pages

  2. D30/5/4Q-E2

    1  Page

  3. D30/5/4Q-E1

    1  Page

  4. 19X581

    1  Page

  5. 19X432

    1  Page

  6. 16X561

    1  Page

  7. 16X402

    1  Page

  8. 13X531

    1  Page

  9. 13X372

    1  Page

  10. 10X252

    1  Page

  11. 10X251

    1  Page

  12. 19 x 431

    1  Page

  13. 22 x 451

    1  Page

  14. 22 x 452

    1  Page

  15. 22 x 602

    1  Page

  16. 16 x 401

    1  Page

  17. 13 x 371

    1  Page

  18. C85MS1-L5

    4  Pages

  19. C85MS1-L4

    3  Pages

  20. C75MS1

    3  Pages

  21. C68SS1

    3  Pages

  22. C65T1

    3  Pages

  23. C65S1

    3  Pages

  24. C65MS1-04

    4  Pages

  25. C65MS1

    3  Pages

  26. C65D1

    3  Pages

  27. C60S1-04

    3  Pages

  28. C60S1

    3  Pages

  29. C55H1-01

    3  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.