E-mail: [email protected], URL: www.boreasa.com Miniature Centrifugal Blower C65S1-24PR-01-Lx 65.5 x 63 x 48 mm (2.58 x 2.48 x 1.89 in) ∗ Housing / Impeller Materials: Medical Grade Thermoplastics ∗ Lead Wire: 235 mm (AWG22 & AWG28) ∗ Weight: 215 gr. (7.58 oz) ∗ Operational Temperature: -20 to +50°C / -4 to +122°F ∗ Three Phase Brushless Motor w/ Hall Sensor ∗ Connector(s): TE CST-100 II 1375820-3 & TE Micro-Match 215083-6 ∗ Standard Motor Internal Temperature Signal ∗ Note: This blower uses a brushless motor and needs a driver to operate ∗ Available in 12 V on demand Note: - Performances are dependent on the driver used and the test conditions. The data in this spec. sheet was obtained using Boreasa test chamber at 20°C (±2°C) and sea level, and using a Boreasa D30/5/4Q-E2 driver. It may be different than data measured in other conditions or with other drivers. - When used as a vacuum, the blower performance might be less than shown herein, depending on the operating point. - Specifications are subject to change without notice. - Boreasa blowers have been designed and are manufactured to meet the medical device industry requirements. However, it is not possible to test blowers in all conceivable customer application configurations. Consequently, to be used in life support equipment, blowers must be life tested and validated by customers, in their actual application conditions, in a statistically meaningful quantity.
Open the catalog to page 1E-mail: [email protected], URL: www.boreasa.com #1 At given working points and cycle. #2 Measured at distance of 1 meter from inlet, with open inlet, outlet connected to breathing tube and 4 mm orifice in sound chamber at 10 cmH2O. N ote : - Working point is an example close to 50% of max. flow. - The phase inductance and impedance are measured by LCR at 1 kHz, including the connector. - Tolerances based on specified speed data according to ISO 13348, grade 4: pressure ±10%, power +16%, speed ±5% and flow rate ±5%.
Open the catalog to page 2E-mail: [email protected], URL: www.boreasa.comPIN Blower Limits and Warning Description Motorwinding U Motorwinding V Motorwinding W Hall sensor A Hall sensor B Hall sensor C VHall (5 ... 24 VDC) GND NTC * Blocking the impeller more than 20 seconds may result in damages or destruction of the blower. * A minimum air flow is required at VCC higher than Nominal Voltage to avoid the air in the blower to overheat by compressing and mixing. Manufacturing System Blowers manufactured by ISO9001-2015 certified manufacturer. Motor Internal Temperature Signal (IT) The temperature of the inside of the motor...
Open the catalog to page 31 Page
4 Pages
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
3 Pages
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
4 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
4 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages