C65T1
1 /3Pages

C65T1

C65T1
1 /3Pages

Catalog excerpts

C65T1-1

E-mail: [email protected], URL: www.boreasa.com Miniature Centrifugal Blower C65T1-24PR-05-L3 69 x 74.5 x 30.6 mm (2.72 x 2.93 x 1.2 in) ∗ Housing / Impeller Materials: Thermoplastics ∗ Lead Wire: 245 mm (AWG22) ∗ Weight: 160 gr. (5.64 oz) ∗ Operational Temperature: -20 to +50°C / -4 to +122°F ∗ Three Phase Brushless Motor w/o Hall Sensor ∗ Connector(s): TE CST-100 II 1375820-3 ∗ Note: This blower uses a brushless motor and needs a driver to operate ∗ Available in 12 V on demand Note: - Performances are dependent on the driver used and the test conditions. The data in this spec. sheet was obtained using Boreasa test chamber at 20°C (±2°C) and sea level, and using a Boreasa D30/5/4QF-E2 driver. It may be different than data measured in other conditions or with other drivers. - When used as a vacuum, the blower performance might be less than shown herein, depending on the operating point. - Specifications are subject to change without notice. - Boreasa blowers have been designed and are manufactured to meet the medical device industry requirements. However, it is not possible to test blowers in all conceivable customer application configurations. Consequently, to be used in life support equipment, blowers must be life tested and validated by customers, in their actual application conditions, in a statistically meaningful quantity.

 Open the catalog to page 1
C65T1-2

E-mail: [email protected], URL: www.boreasa.com #1 At given working points and cycle. #2 Measured at distance of 1 meter from inlet, with open inlet, outlet connected to breathing tube and 4 mm orifice in sound chamber at 10 cmH2O. N ote : - Working point is an example close to 50% of max. flow. - The phase inductance and impedance are measured by LCR at 1 kHz, including the connector. - Tolerances based on specified speed data according to ISO 13348, grade 4: pressure ±10%, power +16%, speed ±5% and flow rate ±5%.

 Open the catalog to page 2
C65T1-3

E-mail: [email protected], URL: www.boreasa.com Electrical Connections Description Motorwinding U Motorwinding V Motorwinding W Wire Brown Blower Limits and Warning Manufacturing System * Max. allowed temp. on heat-sink: 75°C * Blocking the impeller more than 20 seconds may result in damages or destruction of the blower. * A minimum air flow is required at VCC higher than Nominal Voltage to avoid the air in the blower to overheat by compressing and mixing. Blowers manufactured by ISO9001-2015 certified manufacturer.

 Open the catalog to page 3

All Boreasa Technologies Co., Ltd catalogs and technical brochures

  1. D30/5/4Q-M2

    4  Pages

  2. D30/5/4Q-E2

    1  Page

  3. D30/5/4Q-E1

    1  Page

  4. 19X581

    1  Page

  5. 19X432

    1  Page

  6. 16X561

    1  Page

  7. 16X402

    1  Page

  8. 13X531

    1  Page

  9. 13X372

    1  Page

  10. 10X252

    1  Page

  11. 10X251

    1  Page

  12. 19 x 431

    1  Page

  13. 22 x 451

    1  Page

  14. 22 x 452

    1  Page

  15. 22 x 602

    1  Page

  16. 16 x 401

    1  Page

  17. 13 x 371

    1  Page

  18. C85MS1-L5

    4  Pages

  19. C85MS1-L4

    3  Pages

  20. C75MS1

    3  Pages

  21. C68SS1

    3  Pages

  22. C65S1

    3  Pages

  23. C65S1-0B

    3  Pages

  24. C65MS1-04

    4  Pages

  25. C65MS1

    3  Pages

  26. C65D1

    3  Pages

  27. C60S1-04

    3  Pages

  28. C60S1

    3  Pages

  29. C55H1-01

    3  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.