E-mail: [email protected], URL: www.boreasa.com Miniature Centrifugal Blower * Housing / Impeller Materials: Medical Grade Thermoplastics * Three Phase Brushless Motor w/ Hall Sensor * Standard Motor Internal Temperature Signal * Note: This blower has an integrated driver Note: - Performances are dependent on the driver used and the test conditions. The data in this spec, sheet was obtained using Boreasa test chamber at 20°C (±2°C) and sea level. It may be different than data measured in other conditions. - When used as a vacuum, the blower performance might be less than shown herein, depending on the operating point. - Specifications are subject to change without notice. - Boreasa blowers have been designed and are manufactured to meet the medical device industry requirements. However, it is not possible to test blowers in all conceivable customer application configurations. Consequently, to be used in life support equipment, blowers must be life tested and validated by customers, in their actual application conditions, in a statistically meaningful quantity.
Open the catalog to page 1E-mail: [email protected], URL: www.boreasa.com Technical Data #1 At given working points and cycle. #2 Measured at distance of 1 meter from inlet, with open inlet, outlet connected to breathing tube and 4 mm orifice in sound chamber at 10 cmH20. Note: - Working point is an example close to 50% of max. flow. - Tolerances based on specified speed data according to ISO 13348, grade 4: pressure ±10%, power ±16%, speed ±5% and flow rate ±5%.
Open the catalog to page 2E-mail: [email protected], URL: www.boreasa.com Electrical Connections Speed Calculation Input Voltage Description VCc (Power Supply +) VSp (Speed Control Voltage) FG (Frequency Generator) NTC NTC Blower speed [rpm] = 20 * FG FG = Frequency Generator FG = High Power Supply Requirements Blower Limits and Warning nning compare to input voltage ing with 100% speed VSp not connected VSP to GND Voltage Ripple Voltage Current locking the impeller more than 20 seconds may result in damages or destruction of the blower, imum air flow is required at Vcc higher than Nominal Voltage to avoid the air in...
Open the catalog to page 3E-mail: [email protected], URL: www.boreasa.com Typical Hookup 1. Measuring the Generator Frequency to calculate the blower speed. 2. Using an external +5.0 V power supply voltage and a potentiometer to control the blower speed. 3. Using a potentiometer to control the blower speed. 4. Using external analog control signal (0 - 5.0 V) to control the blower speed (note: Do not use DC power supply voltage). 0 - 5.0 V
Open the catalog to page 41 Page