1. Catalogs
  2. Bovie Medical
  3. SMOKE SHARK? II

SMOKE SHARK? II

SMOKE SHARK? II
1 / 25 PagesView full catalog

SMOKE SHARK? II

Product catalog summary
System Description
The Bovie Smoke Shark II is a surgical smoke evacuation system designed to filter smoke and aerosols during procedures. It features a high suction vacuum motor and a Bovie SF35 Filter with four filtration stages: prefilter, ULPA filter, activated carbon, and expanded foam. The system is user-friendly with electronic controls.
Operating Instructions
The manual includes detailed instructions on system controls, filter usage, setup, and operation. It complies with UL 60601-1 and FCC Part 15 standards and is designed for continuous operation with precautions for electromagnetic compatibility.
Maintenance
Regular maintenance involves cleaning, inspection, and troubleshooting. Only Bovie-approved parts should be used to maintain warranty validity.
Customer Service
Information on equipment return and ordering replacement parts is provided. Contact Bovie Medical Corporation for service and repair instructions.
Terms & Warranty
The product has a two-year warranty against defects, contingent on routine maintenance with approved parts. Misuse voids the warranty.
Cautions and Warnings
Warnings include testing equipment before use, avoiding explosive environments, and not blocking tubing or filters. Proper accessories and installation guidelines are crucial to prevent overheating and ensure operability.
Symbols and Meanings
The manual explains symbols for dangerous voltage, non-ionizing radiation, and usage instructions, along with environmental and storage conditions.
System Controls
The system features an electronic control panel with a suction on/off switch, power adjustment, filter life indicator, and service light. It can be operated via footswitch or remote activation.
Filter Life Indicator
The indicator shows filter status, with different flow settings affecting lifespan: low (35 hours), medium (24 hours), high (18 hours). The system stops six hours after the filter life ends unless manually turned off.
Filter Installation and Removal
Install the filter by inserting it into the receptacle and engaging the clip. For removal, turn off the system, disconnect tubing, and dispose of the filter per hospital policy.
Performance Specifications
The system operates at 100/120 VAC or 220/240 VAC with 1000 watts motor power, variable flow control, fuse protection, and a noise level of 55 dBA. It is CE marked and UL classified.
Electromagnetic Compatibility
Complies with IEC60601-1-2 standards, suitable for commercial or hospital use, minimizing interference with nearby electronics.
Maintenance and Troubleshooting
Includes cleaning with a damp cloth and inspections. Troubleshoot by checking filter seating, replacing clogged filters or hoses, and ensuring electrical connections. Contact Bovie for unresolved issues.
Equipment Return and Ordering
Obtain a Return Goods Authorization number before returning equipment. Use original packing materials and contact Customer Service for ordering.
Contact Information
For parts or service, contact Customer Service at 800.537.2790 or +1.727.384.2323, or visit www.boviemed.com.
Product Versions
Available in 100/120 VAC 50-60 Hz and 220/240 VAC 50-60 Hz versions.
Available Accessories
  • Bovie SF35 Filters
  • Suction Canister
  • Remote Activation Device
  • Hoses & Tubing
  • Reducer Fittings
  • Electrosurgical Pencil Adapters
  • Electrosurgical Smoke Pencil
Warranty Information
Two-year warranty for defects in material and workmanship, excluding incidental or consequential damages.
Liability Limitations
Bovie is not liable for special, incidental, indirect, or consequential damages. Liability is limited to the purchase price of the system.
Specifications
Specifications are subject to change without notice.
Shipping and Returns
Customer shipping requests are accommodated, but Bovie reserves the right to decide on prepaid orders. Claims for discrepancies must be made within 24 hours of delivery. Returns require a pre-authorized number and must be prepaid. Unauthorized returns will be refused.
See more

Catalog excerpts

SMOKE SHARK? II-1

make !hark Smoke Evacuator Operator’s Manual © 2015 Bovie Medical Corporation 5115 Ulmerton Road Clearwater, Florida 33760 US Phone: 1.800.537.2790 Fax: 1.800.323.1640 International Phone: +1 727 384 2323 www.boviemed.com

 Open the catalog to page 1
SMOKE SHARK? II-2

For a period of two (2) years following the date of delivery, Bovie Medical Corporation warrants the Smoke Shark II against any defects in material or workmanship. Bovie Medical Corporation will repair or replace (at Bovie Medical Corporation’s option) the same without charge, provided that routine maintenance as specified in this manual has been performed using replacement parts approved by Bovie Medical Corporation. This warranty is void if the product is used in a manner or for purposes other than intended. © 2015 Bovie Medical Corporation 5115 Ulmerton Road Clearwater, Florida 33760 US Phone:...

 Open the catalog to page 2
SMOKE SHARK? II-3

Table of Contents & List of Illustrations Section Title Page 1.0 SYSTEM DESCRIPTION 3 1.1 Introduction 1.2 Inspection 1.3 Operational Information 1.4 Cautions and Warnings 2.0 2.1 2.2 2.3 2.4 OPERATING INSTRUCTIONS System Controls Bovie® SF35 Filter Instructions Set-up and Operation Specifications MAINTENANCE General Maintenance Information Cleaning Periodic Inspection Troubleshooting CUSTOMER SERVICE Equipment Return Ordering Information 5.0 TERMS & WARRANTY 23 Figure Title Page 1 Control Panel 10 Smoke Shark II Operator’s Manual: Page 2

 Open the catalog to page 3
SMOKE SHARK? II-4

System Description Section 1.0 Bovie® Smoke Shark II Smoke Evacuation Systems are intended to evacuate and filter surgical smoke plume and aerosols created by the interface surgical tools with tissue, examples being lasers, electrosurgery systems, and ultrasonic devices. The Smoke Shark II Smoke Evacuation Systems have been designed with a high suction, high flow rate vacuum motor. The ultra-quiet motor is used to draw the surgical smoke from the surgical site through the vacuum tubing and into the Bovie® SF35 Filter where the surgical smoke is processed by a series of filters. A single disposable...

 Open the catalog to page 4
SMOKE SHARK? II-5

In addition, please compare the accessories you receive with the standard accessories list below. If an item is missing, please notify Bovie Medical Corporation Customer Service. Standard Accessories: • Operator’s Manual • Power Cord • Pneumatic Footswitch Please contact Bovie Medical Corporation Customer Service to purchase the following accessories: • Replacement Filters • Remote Activation Device • Hoses, Tubing, Laparoscopic Kits, Adapters, Wands & Other Accessories 1.3 Operational Information The operational information contained in this section is intended for the customer review of regulatory...

 Open the catalog to page 5
SMOKE SHARK? II-6

10. The fuses on the motor circuit are to be serviced by an authorized Bovie Medical Corporation technician as follows: 220/240 VAC, 50/60 Hz – use F3.15AH250V Fuse (3,15 Amp 250 Volt [Fast-Acting]), (F3) 11. This equipment needs special precautions regarding ElectroMagnetic Compatibility and needs to be installed according to EMC information found in this manual. 12. This equipment utilizes mobile RF communications equipment that can affect medical electrical equipment. 13. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of...

 Open the catalog to page 6
SMOKE SHARK? II-7

1.4.1 WARNINGS: • Read this manual thoroughly, and be familiar with its contents prior to using this equipment. • Test this equipment prior to a surgical procedure. This product was thoroughly tested at the factory before shipment. • Disconnect the unit from the electrical outlet prior to inspecting system components. • The Smoke Shark II system is only intended and suitable for the applications that are mentioned in the operating instructions. • The smoke evacuator produces a strong vacuum. Adjust the airflow and the position of the inlet end of the wand or tubing to prevent patient injury and...

 Open the catalog to page 7
SMOKE SHARK? II-8

• This equipment should not be used adjacent to or stacked with other equipment and that if adjacent or stacked use is necessary, the Smoke Shark II should be observed to verify normal operation in the configuration in which it will be used. • Refer routine servicing to qualified biomedical technical personnel. • Changes or modifications not expressly approved by Bovie Medical Corporation could void the user’s authority to operate the equipment. The warranty on this product is void if any of these warnings are disregarded. 1.4.2 CAUTIONS: • Federal law (United States of America) restricts this...

 Open the catalog to page 8
SMOKE SHARK? II-9

• The ambient temperature during operation must be kept between 50°F to 104°F (10°C to 40°C) • The relative humidity during operation must be kept between 10% to 75%. • An atmospheric pressure range of 700 hPA to 1,060 hPa. • Storage environmental ambient temperature 14°F to140°F (-10°C to 60°C). • Storage environmental relative humidity 10% to 75%. Th re are no user serviceable components in the Smoke Shark II Smoke Evacuation System(s). Refer service to qualified service personnel. Use only with the power cord provided and always plug into a grounded outlet. Smoke Shark II Operator

 Open the catalog to page 9
SMOKE SHARK? II-10

DESCRIPTION/MEANING WARNING: DANGEROUS VOLTAGE TYPE CF APPLIED PART. PROTECTION AGAINST INGRESS OF WATER AS DETAILED IN IEC 60529. ALTERNATING CURRENT. PROTECTIVE EARTH, (GROUND). EQUIPOTENTIALITY. DENOTES THE DATE THE EQUIPMENT WAS MANUFACTURED. MANUFACTURER NON-IONIZING RADIATION MANDATORY: REFER TO INSTRUCTION MANUAL/GUIDE DANGER- EXPLOSION RISK IF USED WITH FLAMMABLE ANESTHETICS. DO NOT USE IF PACKAGING IS DAMAGED OR OPENED. DO NOT RESTERILIZE DO NOT REUSE. THIS IS A SINGLE USE DEVICE. STERILE RADIATION STERILE ETHYLENE OXIDE OPERATING TEMPERATURE LATEX FREE Smoke Shark II Operator’s Manual:...

 Open the catalog to page 10
SMOKE SHARK? II-11

Figure 1 Unit Control Panel SYSTEM MOTOR POWER BUTTON SUCTION SPEED BUTTON: PRESS TO CYCLE THROUGH HIGH, MEDIUM AND LOW SPEEDS MOTOR ON LED INDICATOR STANDBY MODE LED INDICATOR SERVICE/TROUBLESHOOTING REQUIRED LED INDICATOR MOTOR SPEED LED INDICATORS: Upper Light: HIGH SPEED Center Light: MEDIUM SPEED Lower Light: LOW SPEED CURRENT FILTER LIFE INDICATOR: AS LIGHTS MOVE FROM GREEN TO RED, FILTER LIFE DEPLEATS. REPLACE FILTER WHEN RED. Smoke Shark II Operator’s Manual: Page 10

 Open the catalog to page 11
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.