Catalog excerpts
iPLAN® MONTE CARLO DOSE CALCULATION Precise dose calculations within seconds for SBRT iPlan® Monte Carlo dose calculation offers fast, accurate dose calculations for more precise treatment of extracranial indications—expanding SBRT treatment possibilities. iPlan Monte Carlo performs dose calculations within seconds for conformal beam and dynamic arc treatments and within minutes for complex IMRT cases. Seamless integration allows for use with all major linear accelerators and multi-leaf collimator (MLC) types. This advanced calculation method eliminates treatment area restrictions of conventional dose calculation algorithms1 for highly precise treatment delivery to inhomogeneous regions including lung and head & neck indications. Unmatched speed and intuitive user interface enable broader treatment spectrum and use with every patient Customizable solution adapts to specific Linac and MLC configurations Integrates with iPlan RT Image and Automatic contouring tools to further enhance treatment planning efficiency, consistency and accuracy Enables photon based MLC treatments including conformal beam, dynamic arc, IMRT and composite planning for combined treatment modalities iPlan Monte Carlo IMRT dose display for head & neck indications
Open the catalog to page 1MORE PRECISE TREATMENT DELIVERY iPlan® Monte Carlo is a high performance Monte Carlo algorithm for therapeutic photon beam radiation delivery. Based on the XVMC (X-Ray Voxel Monte Carlo) algorithm, iPlan Monte Carlo was developed to provide high-precision treatment in everyday clinical practice and has been verified using the widely respected EGSnrc and BEAMnrc algorithms. iPlan Monte Carlo is an integral part of iPlan RT Dose, offering advanced technology for multiple treatment approaches. iPlan Monte Carlo considers Linac head geometry, secondary electron dose effects and tissue...
Open the catalog to page 2All Brainlab catalogs and technical brochures
-
Buzz In-Wall
6 Pages
-
NAVIGATED DISPOSABLE STYLET
1 Pages
-
NAVIGATED FRAMELESS BIOPSIES
2 Pages
-
CRANIAL ACCESSORIES
13 Pages
-
iPlan RT Adaptive
2 Pages
-
iPlan RT Dose
2 Pages
-
iPlan HybridArc
2 Pages
-
iPlan Flow
2 Pages
-
LIVE IMAGING
2 Pages
-
KingMark
1 Pages
-
VoyantMark
1 Pages
-
Brochure Novalis
2 Pages
-
Brochure Elekta – ExacTrac
1 Pages
-
KNEE 3
15 Pages
-
iPlan Cranial
2 Pages
-
Integrated MR
1 Pages
-
Microscope Integration
2 Pages
-
Cranial Navigation
2 Pages
-
Quentry
12 Pages
-
Hip Navigation
23 Pages
-
Product Catalog Neurosurgery
9 Pages
-
Elements
14 Pages
-
Radiolucent Skull Pins
1 Pages
-
Vero sBrt unleashed
12 Pages
-
IMMEDIATE IMPACT
1 Pages
-
AIRO
10 Pages
-
Brochure Spine Navigation
19 Pages
-
Curve
18 Pages
-
Flyer Knee Express
2 Pages
-
Flyer Hip Express
2 Pages
-
Buzz
12 Pages
-
iPlan
5 Pages