KingMark

KingMark

Product catalog summary
Overview: KingMark® is a double calibration device designed for AP Pelvic X-ray images, offering enhanced accuracy over conventional single-ball markers. It is suitable for patients of all sizes and simplifies the positioning process.
Specifications: The device consists of two markers: an anterior flexible strap with radio-opaque balls and a posterior radiolucent pad with embedded steel rods. The anterior marker secures the balls at regular intervals, while the posterior marker is positioned under the hips.
Procedures: KingMark is positioned midline, ensuring visibility within the radiograph. The technique remains consistent across different patient sizes, avoiding awkward or invasive methods. The device's design allows for quick and easy positioning, with visual cues to prevent errors.
Automatic Calibration: TraumaCad software automatically detects KingMark in X-ray images, calculates magnification, and adjusts for accurate measurements and template selection.
Key Features: - Accurate calibration for all patient sizes. - Quick and easy positioning. - Visual indicators for correct placement. - Automatic detection and calibration by TraumaCad.
Benefits: KingMark provides reliable and precise calibration, reducing the likelihood of positioning mistakes and improving the accuracy of anatomical measurements.
See more

Catalog excerpts

KingMark-1

Accurate calibration every time. Accurately calibrate images and measure patient anatomy Ball-strip contains 5 radio-opaque balls. Strap holds the ball-strip to the front of the patient. KingMark® is a double calibration device for AP Pelvic X-ray images. In clinical trials, KingMark performed four times more accurately than the conventional, single-ball marker as it’s easier to position correctly and the technique is the same for all sizes of patients. Weight helps keep ball-strip and strap snug to the patient’s body. Two is better than one KingMark uses two separate markers- one behind the pelvis and one in front. The anterior marker is a flexible strap that secures radio-opaque balls at regular intervals. The posterior marker is a radiolucent pad with steel rods embedded in a vertical row. Accurate in all sizes of patients Single markers can be difficult to use in very large patients. Since KingMark is positioned midline, it always appears within the radiograph. The correct positioning technique is the same for all sizes of patients and is not awkward or invasive. Automatic calibration Quick and Easy to position KingMark is very quick and easy to position. It is visually apparent on the radiograph when markers are incorrectly positioned, thus preventing positioning mistakes. TraumaCad automatically detects the presence of KingMark in an x-ray image, determines the magnification percentage and re-sizes it to allow accurate measurements and templates selection. Brainlab AG Kapellenstraße 12 85622 Feldkirchen Germany brainlab.com Customer Support: [email protected] © All Rights Reserved | OR_PO_EN_Orthopedic Planning_KingMark Product Sheet_Mar15_Rev2 Base is positioned under hips as patient lies supine on the x-ray table. Base contains radio-opaque

 Open the catalog to page 1