video corpo

Vero sBrt unleashed
12Pages

{{requestButtons}}

Catalog excerpts

Vero sBrt unleashed - 2

Vero finally combines the latest developments of the last decade into one system. Vero™ SBrt promising unleashed all around PROF. DIRK VERELLEN | Head of Medical Physics UZ Brussels Vero™ is about more than cutting-edge technology; engineered into its core is an unprecedented integration, unrestrained research potential, and unlimited long-term investment. Housed inside a modern shell, Vero delivers an ease of handling and intuitive workflow that will change the way hospitals integrate technology. Vero’s speed, accuracy and versatility may drive shorter treatment times, higher patient...

Open the catalog to page 2
Vero sBrt unleashed - 3

Exact Perfection high mechanical accuracy through closed ring gantry design Final isocenter definition (R): 0.22962 mm 288° 216° STAR SHOT FILM With its gimbal mechanism, Vero targets the isocenter from any angle with precision of up to 0.1 mm. Vero offers an increase in mechanical accuracy with its closed ring design. You can calibrate Vero to a pre-defined isocenter, which may increase treatment precision. Target the tumor from any angle with Vero’s gimbaled accelerator and multi-leaf collimator, compensating for even small deviations and enabling great precision. > Treat with increased...

Open the catalog to page 3
Vero sBrt unleashed - 4

unrestricted imaging capabilities in any treatment position Stereo x-ray stereo fluoroscopy Instant verification just a fingertip away. Always-ready imaging capabilities at any treatment position. Vero integrates innovative imaging and positioning capabilities. Perform treatment with dual-diagnostic x-ray for simultaneous stereo imaging, 6D patient positioning, and verification at any gantry angle and at any time during treatment. Save set-up and verification time with dual-source Cone Beam CT*. Make one dream a reality with Vero’s stereo fluoroscopy, allowing real-time imaging of moving...

Open the catalog to page 4
Vero sBrt unleashed - 5

manage tumor motion through robotic adjustment of beam assembly Dose profile Film Dose distributions Combined infrared and fluoroscopyguided Real-Time Tumor Tracking* Vero provides high accuracy for treatment delivery, even with moving targets. Core features, such as sophisticated and versatile image-guidance and verification tools, and the first-of-its-kind gimbaled irradiation head with tilt functions – for isocentric and non-isocentric treatments* – deliver targeting confidence. With built-in fluoroscopy, you can dynamically treat tumor areas, even as they move in parallel with breathing...

Open the catalog to page 5
Vero sBrt unleashed - 6

angular freedom without moving the patient Seamless planning and delivery of coplanar and non-coplanar treatments. Vero allows you to freely choose and combine beam configurations, using coplanar and non-coplanar treatment angles. Maintain high accuracy, even when you employ non-coplanar beam configurations because you need not move the couch or reposition the patient. Once positioned, the patient remains stationary throughout treatment while the system moves with great angular freedom. You deliver precise treatment, from more angles, with less time and effort. > Choose and combine beam...

Open the catalog to page 6
Vero sBrt unleashed - 7

Plan with confidence Automatic Image Fusion AUTOMATIC IMAGE FUSION iPlan® offers highly advanced image fusion capabilities. Automatic, accurate co-registration of various data sets offers the necessary precision for stereotactic treatments. ELASTIC IMAGE FUSION* Elastic image fusion allows you to automatically segment 4D CT data sets subsequent CBCT data sets and follow-up CT data sets. Evaluate tumor motion, tumor deformation, tumor growth/shrinkage and changes in dose distribution. Evaluate and adapt with ease and speed. supported by highly sophisticated software Elastic image fusion...

Open the catalog to page 7
Vero sBrt unleashed - 8

Handle with ease HYBRIDARC™* SBRT with HybridArc™ dose planning software can shorten treatment times, increase target coverage and improve sparing of organs at risk, compared to conventional techniques. even the most challenging treatment techniques Monte Carlo DYNAMIC WAVE ARC* Make the most of Vero’s motion capabilities with Dynamic Wave Arc. This new treatment technique employs simultaneous gantry and ring motion during dose delivery for effective dose-to-PTV conformality and improved avoidance of organs at risk. MONTE CARLO Ideal for extracranial treatments where you experience...

Open the catalog to page 8
Vero sBrt unleashed - 9

Adapt seamlessly dual kV Cone Beam CT imaging and fast plan adjustment for adaptive RT Evaluation Elastic fusion of CT to CBCT. Autosegmentation of CBCT. Evaluation of organ volume changes, dose conformity, coverage and dose thresholds. Patient treatment initial treatment planning Vero provides anatomic images of high quality through its dual kV imaging systems. Take advantage of sophisticated planning capabilities for fast plan adjustment. As a platform for adaptive RT*, Vero’s imaging and motion management tools are based on the real-time, ever-changing patient condition. Vero merges...

Open the catalog to page 9
Vero sBrt unleashed - 10

intuitive workflows with integration enabling on-site or remote treatment participation Vero SBRT Digital Lightbox Laser for semi-automatic patient pre-positioning Gimbal mechanism for isocenter calibration and tumor chasing Dynamic micro MLC with low leakage and high drive speed Ring > mechanically extremely stable Ring rotation mechanism > +/- 60° > quick and precise switch from coplanar to non-coplanar treatments EPID Electronic Portal Imaging Device for MV x-ray imaging Beam stopper to reduce radiation shielding requirements Patient positioning and diagnostic imaging system „Exactrac®...

Open the catalog to page 10
Vero sBrt unleashed - 11

With its unique, dynamic tracking capabilities, coupled with advanced real-time imaging and ability to treat from nearly any direction, Vero is the ultimate SBRT platform. TIMOTHY SOLBERG | PHD, Director of Medical Physics and Engineering UT Southwestern Medical Center at Dallas

Open the catalog to page 11
Vero sBrt unleashed - 12

SBRT UNLEASHED Vera GmbH I KapellenstraBe 12 I 85622 Feldkirchen I GERMANY I www.vero-sbrt.com

Open the catalog to page 12

All Brainlab catalogs and technical brochures

  1. Buzz In-Wall

    6 Pages

  2. iPlan Flow

    2 Pages

  3. LIVE IMAGING

    2 Pages

  4. KingMark

    1 Pages

  5. VoyantMark

    1 Pages

  6. KNEE 3

    15 Pages

  7. Quentry

    12 Pages

  8. Hip Navigation

    23 Pages

  9. Elements

    14 Pages

  10. AIRO

    10 Pages

  11. Curve

    18 Pages

  12. Buzz

    12 Pages

  13. iPlan

    5 Pages