Product information Resilient and secure connection
Open the catalog to page 1The unique retention system from bredent medical The TiSi.snap abutments with large r t nitton sutl.r ■ s and ih" r -.ilient g ■■ ■■ ial silicone retention.sil set new standards for the reliable and long-term fixation of prostheses.
Open the catalog to page 2Durable Flexible The resilience of retention.sil is comparable to the resilience of soft tissue and protects the implants and abutments from overloading and ensures a natural chewing feeling. The prosthesis can be fixed immediately after placement of the implant. Minimally invasive treatment by using narrow and ultra-short implants to utilise the existing bone, so that even patients with health impairments can be treated to improve their quality of life.
Open the catalog to page 3SKY TiSi.snap & retention.silThe benefits ■ Minimally invasive thanks to the use of narrow, short, ultra-short and angled implants ■ Compensation for implant divergences with one-piece, 17.5° angled TiSi.snap abutments ■ Use of standard tools and instruments ■ Reliable incorporation of resilient silicone for prosthesis fixation thanks to special primer ■ Immediate and delayed restoration ■ retention.sil for resilient anchoring ■ Dockloc® matrices for snap function ■ Allows individual TiSi designs
Open the catalog to page 4retention.sil Three different frictions Easy chairside application: Primer for PMMA and retention.sil Stable even under high lateral forces in the atrophied jaw Resilient like gingiva Patient-friendly Simple and easy prosthesis removal and insertion Quality of life thanks to secure hold Cost-effective, since no matrices are required Lasts for up to 5
Open the catalog to page 5Resilient prosthesis fixation Natural chewing feeling Narrow implants in the front and posterior ultra short implants improve the stability of the prosthesis thanks to their large support area. No pressure is applied to the bone that can lead to bone loss. As with earthquake-proof construction, the elastic retention.sil dampens the chewing forces and thus fixes the prosthesis. retention.sil has a similar elasticity to the gums and encloses the entire structure so that the lateral forces are also absorbed. The prosthesis is prevented from rocking.
Open the catalog to page 6“The robust prosthesis fixation with TiSi.snap – retention.sil provides our patients with maximum comfort while chewing and a secure hold” Dr. Aram Raie Lemwerder, Germany “Thanks to the restoration with TiSi.snap and retention.sil in combination with ultrashort and narrow implants, angled if clinically necessary, I can provide minimally invasive care to my elderly patients so that they can eat, talk, sing and laugh again.” Prof. Dr. Jörg Neugebauer Landsberg/University of Cologne,
Open the catalog to page 7Contents: retention.sil in 3 hardnesses Mixing cannulae and extraction instrument Multisil-Primer
Open the catalog to page 8Chairside application steps Locate the abutment position, e.g. with thin-flowing impression material Grind the restoration at the abutment positions Apply a thin layer of Multisil Primer to PMMA resin Allow to flash off for 3 minutes Fill the cavity to 2/3 with retention.sil 200. The dispenser simplifies the application of retention.sil TiSi.snaps must not be in contact with the prosthesis base! Apply restoration, have the patient bite gently Important: It is not necessary to block out undercuts! Remove restoration after 5 minutes Remove excess with scissors, scalpel or round bur (SKY-DR41)....
Open the catalog to page 9Holding force Locator LR blue retention.sil 200 retention.sil 400 retention.sil 600 Removal/insertion cycle Figure Retentive properties of an overdenture attachment system made of vinyl polysiloxane Based on retentive characteristics of a vinyl polysiloxane overdenture attachment system Ramona Schweyen & Florian Beuer & Christian Arnold & Jeremias Hey Clinical Oral Investigations 2024 A scientific study confirmed the durability of retention.sil. retention.sil had a stable pull-off force over the entire examination period, which corresponds to a wearing time of about 5 years. The locator array...
Open the catalog to page 10“Elastic prosthesis fixation with TiSi.snap and retention.sil showed stable long-term results in our studies. Its ease of use and durability in clinical application are a delight to patients and staff alike.” Prof. Dr. Jeremias Hey University of Halle, German
Open the catalog to page 110091181GB-20240404 Mistake and subject to change reserved bredent medical bredent! bredent medical GmbH & Co. KG • Weissenhorner Str. 2 • 89250 Senden • Germany • T: +49 7309 872-440 • F: +49 7309 872-444 • [email protected] • www.bredent-medical.com
Open the catalog to page 1256 Pages
4 Pages
24 Pages
12 Pages
24 Pages
2 Pages
32 Pages