whiteSKY Alveo Line & Tissue Line Irrtum Mistake Ne rezervăm und andÄnderungen subject dreptulto la change modifi vorbehalten cări reserved și erori Zirconia implant 11.12.2020 // pab Laut Fr. Rebecca Stöferle und Frau Beth Hollis wird die Adresszeile für die SKY Bestellinformation (REF 0091009GB-20201211) EINMALIG mit der Mailadresse „[email protected]“ verarbeitet. Ansonsten gilt für alle UK Drucksachen weiterhin die Mailadresse „[email protected]“. bredent bredent bredent medical group medical bredent România GmbH GmbH UK&Ltd Co. · &Bdul. ·Co. Tapton KGKG Mircea · Weissenhorner · Alex Park Vodă Liu Innovation ·21D, BEIJING Str. sector 2Centre SHUNRUI · 89250 3, București, · Brimington Senden Tech Co., cod · Germany Road Ltd. poștal · 4F · Chesterfi 030662 ·of T: Building +49 ·7309 eld România S41 12, 872-600 No. 0TZ · T: 28 · T: +40 ·Yuhua F: +44 +49 212240702 1246 Road 7309 559599 of 872-635 /Airport +40 · www.bredent.co.uk 742583759 · www.bredent-medical.com Economic· Zone, www.bredentgroup.ro Shunyi · @: [email protected] District, · @: [email protected] Beijing, · [email protected] 101300 · China · T: +8610 80470321 · M: +8613 910012991 · ww
Open the catalog to page 1Reshaping scientific SUCCESS The whiteSKY implant system has proven its worth on both a clinical and scientific level since its launch in 2006. Published, science-based long-term results spanning over more than 10 years attest to its success. These findings prove that whiteSKY zirconia implants can achieve results which are comparable to those obtained with titanium implants. The second generation of whiteSKY now incorporates all the advantages of the original whiteSKY in a modern, enhanced design: “Reshaping scientific success”. Studies have also investigated and demonstrated osseointegration...
Open the catalog to page 3Zirconia implant One piece Versatile Reliable Proven manufacturing process and therapy whiteSKY A.L. and T.L. retain the onepiece design and intricate fabrication from compressed zirconia. This ensures whiteSKY implants are extremely stable, a key factor for whiteSKY’s long-term success. The blasted surface combined with the bone quality-oriented surgical protocol produces high primary stability in all bone qualities. This high primary stability is the basic prerequisite for immediate restoration with whiteSKY zirconia implants. Macromounting | whiteSKY surface The benefits The beneficial characteristics...
Open the catalog to page 4Two angled surfaces, 15° each less individualisation required to restore angled implants Optimised bonding surfaces Optimised abutment height (4.5 mm) Simplifies prosthetic restoration Groove Fixation of prosthetics - “Cement lock“ Optimised self-tapping thread Less force required to screw the implant in Optimised surface structure For soft tissue attachment (see left, Fig. 1) Rough surface For reliable osseointegration (see left, Fig. 3) Rectangular attachment connection Anti
Open the catalog to page 5Zirconia implant Next level Further development of the whiteSKY zirconia implant into the whiteSKY Tissue Line and whiteSKY Alveo Line. Voluminous shoulder Cavity filling immediately after extraction
Open the catalog to page 6Concave collar Space for cosmetic soft tissue formation
Open the catalog to page 7Zirconia implant whiteSKY Analogue or digital You have the choice Easy to use – analogue or digital. There is an optimized solution for both procedures, which can be used for both the whiteSKY Alveo Line and the whiteSKY Tissue Line. Conventional impression with and without impression coping Conventional fabrication of crowns and bridges for plaster and printed models Your analogue solutio
Open the catalog to page 8Intra-oral scan directly from the implant Temporary and definitive restoration CAD/CAM production Your digital solution
Open the catalog to page 9Zirconia implant ‘In addition to reliable osseointegration, I am particularly impressed by the excellent, aesthetically pleasing gingival condition achieved within just a few weeks.’ Dr Holger Scholz Constance, Germany Dr Siegmund Döttelmayer Bad Aussee, Austria whiteSKY implants are ideal for immediate implantation and achieve optimum primary stability. The perfect roughness of the zirconia surface leads to very good wound healing and attachment of mucous membrane. Dr Luis Lapa Bessa Porto, Portugal The design of the new whiteSKY Tissue Line implants stands out as it is perfectly matched to...
Open the catalog to page 10A Clinical and Radiographic Evaluation of Zirconia Dental Implants: 10-Year Follow-Up Excerpt from the scientific article by Prof. Dr Andrea Enrico Borgonovo Hindawi, International Journal of Dentistry, December 2021 Prof. Dr Andrea Enrico Borgonovo Milan, Italy Purpose The aim is to evaluate survival and success rates as well as marginal bone loss (MBL) and the periodontal index of zirconia implants with a 10-year follow-up. Results Survival and success rates were 100%. The average marginal bone loss from the initial value was 0.92 ± 0.97 mm up to 120 months after surgery. Materials and methods...
Open the catalog to page 11Mistake and subject to change reserved bredent medical GmbH & Co. KG · Weissenhorner Str. 2 · 89250 Senden · Germany · T: +49 7309 872-440 · F: +49 7309 872-444 · www.bredent-medical.com · @: info-medical@bredent
Open the catalog to page 1256 Pages
12 Pages
4 Pages
24 Pages
12 Pages
24 Pages
2 Pages
32 Pages