Product Overview: Belzer UW® Cold Storage Solution is formulated for the flushing and cold storage of kidney, liver, and pancreas organs. It is not intended for direct injection or intravenous infusion due to its high potassium content, which poses a risk of cardiac arrest.
Specifications: The solution contains electrolytes with sodium at 29 mEq/L and potassium at 125 mEq/L. The calculated osmolarity is approximately 320 mosmol/kg.
Warnings: The solution is not for in situ flushing of organs in living donors or patients. Any unused portions should be discarded. It is crucial to ensure the solution is clear and free of precipitate before use. If particulate matter, precipitates, or contamination are evident, or if a leak is found, the entire container should be discarded.
Storage Instructions: Store the solution indoors at temperatures between 2° and 25°C (36° and 77°F). Avoid excessive heat and do not freeze. The solution should not be used if frozen.
Legal and Manufacturing Information: The product is a trademark of the Wisconsin Alumni Research Foundation, licensed to Bridge to Life Ltd. It is manufactured by Preservation Solutions, Inc. Federal law restricts this device to sale by or on the order of a physician.
See more

Catalog excerpts

Bag Label-1

Belzer UW® Cold Storage Solution (UW Solution) (Formulated for flushing and cold storage of kidney, liver, and pancreas organs) Warning: NOT intended for direct injection or I.V. infusion High Potassium Content - Risk of Cardiac Arrest Warning: NOT for in situ flushing of organs in living donors or patients Warning: Discard any unused portions Electrolytes (mEq/L): Sodium 29, Potassium 125 Calculated Osmolarity: Approximately 320 mosmol/kg Belzer UW ® Cold Storage Solution is sterile and non-pyrogenic. Use only if solution is clear and free of precipitate. Remove the overwrap and perform a visual inspection of the solution for particulate matter. Do not use this solution if obvious particulate matter, precipitates, or contamination are evident in the solution. If a leak is found, discard the entire container of Belzer UW ® Cold Storage Solution as sterility may be compromised. Single dose container. Store Belzer UW ® Cold Storage Solution indoors at temperatures between 2° and 25°C (36° and 77°F). Avoid excessive heat. Do not freeze the solution and do not use if frozen. See package insert for complete information. CAUTION: Federal (USA) law restricts this device to sale by or on the order of a physician. Manufactured by: Preservation Solutions, Inc. 1099 Proctor Drive Elkhorn, WI 53121 Manufactured for: Bridge to Life Ltd. 128 Suber Road Columbia, SC 29210-3851 Belzer UW® is a trademark of the Wisconsin Alumni Research Foundation (WARF) used under an exclusive license granted to Bridge to Lif

 Open the catalog to page 1

All Bridge to Life catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.