USER MANUAL COMPUTRAC® Vapor Pro® XL MOISTURE ANALYZER AMETEK BROOKFIELD 3375 N Delaware Street | Chandler, AZ 85225 USA 800.528.7411 | 602.470.1414 | f 602.281.1745 www.azic.com Email: Sales – sales.computrac@ametek.com International – international.computrac@ametek.com Customer Service – customerservice.computrac@ametek.com
Open the catalog to page 1
Computrac® Vapor Pro® XL PROPRIETARY RIGHTS NOTICE This manual contains valuable information and material developed by AMETEK Brookfield for use with the Computrac® line of moisture analyzers. No part of this manual can be reproduced or transmitted in any form or by any means, electronic, mechanical or otherwise. This includes photocopying and recording or in connection with any information storage or retrieval system without the express written permission of AMETEK Brookfield. ALL RIGHTS RESERVED © Copyright 2018 AMETEK Brookfield Customer Service 800-528-7411 Manual, Vapor Pro® XL
Open the catalog to page 2
The above Table of Contents, and all section numbers, titles and page numbers in BOLD in this manual are hyperlinks and can be clicked to simplify navigation within the PDF version of the manual. The BACK button found in most PDF programs is also very helpful when navigating the manual using the hyperlinks. An up-to-date electronic copy of this manual can be found at www.azic.com Call Customer Service if you have any questions. If you prefer, you may send e-mail to customerservice.computrac@ametek.com Manual, Vapor Pro® XL
Open the catalog to page 4
WARNINGS AND SAFETY INFORMATION The instrument complies with “UL 61010 Electrical Equipment For Measurement, Control, and Laboratory Use (US, Canada, and Europe)”, electromagnetic compatibility, and the stipulated safety requirements. The instrument is Equipment Class I, Pollution Degree 2, and Installation Category II. The instrument contains a lithium coin cell battery to power the clock when the instrument is turned off. CAUTION – The battery may explode if mistreated. Do not recharge, disassemble, or dispose of in fire. The Temperature Calibration Interface (TCI) is electrostatic...
Open the catalog to page 5
Do not lift the instrument using the vial ramp. Lift from the instrument body instead. Do not open the instrument housing except as directed by this manual. There are no user serviceable parts or user adjustments to be made inside the instrument, except as described herein. Any other maintenance inside the instrument is to be performed by factory-trained technicians only. Any other unauthorized inspection and/or maintenance of the instrument will void the warranty. Use extreme care when handling the discharged sample vial. Although the vials may cool rapidly, they are still very hot when...
Open the catalog to page 6
The outside housing of the instrument should be cleaned with a mild household detergent such as Formula 409 and a soft, lint-free cloth. The touchscreen LCD should be cleaned with lens or eyeglass cleaner only. Paper towels should never be used, as they will scratch the instrument’s finish and the LCD. If methods that are more stringent are required, call Customer Service for recommendations. Cleaning of the flow system components is normally a factory operation. If components become contaminated, follow the directions for an isopropyl alcohol cleaning contained in §18.5 FILTER INSPECTION...
Open the catalog to page 7
QUICK START GUIDE Follow this flowchart to get set up and testing quickly. Refer to §1 WARNINGS AND SAFETY INFORMATION. Refer to §3 UNPACKING, ACCESSORIES, AND SPARE PARTS. Refer to §7 INSTALLATION for installation guidance and §8 OPERATING INSTRUCTIONS for any questions regarding navigating the instrument menu system or user interface. After the dry gas source is connected, perform §18.6 Flow Check and Adjustment to ensure the proper flow rate to the instrument. Refer to §7.4 Accessory Connections to set up any desired USB accessories (such as keyboards or printers) or an external balance....
Open the catalog to page 8
UNPACKING, ACCESSORIES, AND SPARE PARTS The Computrac® Vapor Pro® XL is easy to operate and ready for use upon receipt from the factory. • Remove the instrument from the packing material. Do not lift the instrument using the vial ramp; lift from the instrument body instead. • Retain all packaging materials for any future shipment of the instrument. If the instrument is returned to AMETEK Brookfield for any reason, it must be placed in the original packaging materials that have been tested and proven to be effective protection during shipment. • Locate the following items: PART NAME PART...
Open the catalog to page 9
USB A to B Cable for Printer or PC connection Digital balance with cable and communications software Travel case IQOQPQ Validation Package Technology Transfer Package Kit, Small Crimp Vial Kit, Large Crimp Vial Spare Parts: Vial Caps Septa for Vial Caps Sample Vials Shipping Container Oven Insert Oven Insert Retaining Screw • Check for any damage and confirm receipt of all parts on the packing list. Contact Customer Service if you have any questions. Manual, Vapor Pro® XL
Open the catalog to page 10
REPACKING AND SHIPPING Call AMETEK Brookfield Customer Service at 800-528-7411 or 602-470-1414 or go to the website at www.azic.com for Return Material Authorization (RMA) information prior to returning a unit. Boxes and packing materials for all shipments are available from AMETEK Brookfield. Pack the instrument only in an AMETEK Brookfield shipping container. AMETEK BROOKFIELD will NOT be Responsible for Shipping Damage. IF YOU RETURN THE INSTRUMENT IMPROPERLY PACKAGED OR SHIPPED, YOU SHOULD INSURE IT FOR FULL VALUE. Refer to the diagram below for guidance repacking the Vapor Pro® XL....
Open the catalog to page 11
AMETEK Brookfield is proud to continue its leadership role in developing new technology for the moisture analysis industry. The Computrac® Vapor Pro® XL is a revolutionary high performance programmable moisture analyzer that measures down to very low moisture levels and has the following features: • • • Lower detection limit of 10 ppm, depending on sample size. Operation through a user-friendly color LCD touchscreen. To conserve energy, the LCD automatically dims when the instrument is not used for 30 minutes. A patented system measures low moisture samples without reagents, and correlates...
Open the catalog to page 12All Brookfield catalogs and technical brochures
-
Computrac® MAX® 5000XL
95 Pages
-
Computrac® MAX® 4000XL
105 Pages
-
Jerome® 631-X
50 Pages
-
Jerome® 651
68 Pages
-
JEROME® J605
56 Pages
-
JEROME® 451
80 Pages
-
JEROME® J405
61 Pages
-
JEROME® J505
28 Pages
-
PFT™ Powder Flow Tester
2 Pages
-
CAP 1000+™ & CAP 2000+
2 Pages
-
DV1™ Viscometer
2 Pages
-
Dial Reading Viscometer
1 Pages
-
Temperature Control Baths
3 Pages