1. Catalogs
  2. Bruker Daltonics Inc.
  3. Brochure autoflex-speed 05-2010 (270289)
video corpo

Brochure autoflex-speed 05-2010 (270289)
1 /10Pages

Brochure autoflex-speed 05-2010 (270289)

Brochure autoflex-speed 05-2010 (270289)
1 /10Pages

Catalog excerpts

Brochure autoflex-speed 05-2010 (270289)-1

Bruker Daltonics autoflex speed Increased Efficiency in MALDI-TOF MS think forward

 Open the catalog to page 1
Brochure autoflex-speed 05-2010 (270289)-2

Accelerated Results with Increased Speed and Efficiency The autoflex™ speed series of MALDI based mass spectrometers has been designed to significantly increase productivity across a broad range of applications. With advances in performance and system capabilities, the autoflex speed series has the power, flexibility, and utility to be deployed in many analytical operations. Tissue Imaging Edmass™-Top Down Sequencing Polymer Analysis Complex samples LC MALDI Lucid Proteomics System MALDI Biotyper Microorganism ID Biomarker Discovery

 Open the catalog to page 2
Brochure autoflex-speed 05-2010 (270289)-3

Versatility: autoflex speed The autoflex speed series contains several system options and configurations and can be customized to best suit the applications at hand. The members of the product family include: autoflex speed LRF A reflectron containing system designed to include enhanced applications like peptide analysis; also capable of operation in linear mode. autoflex speed TOF/TOF A linear mode system with outstanding dynamic range optimized for high mass range (>15 kDa) applications and MALDI Tissue Imaging. A high performance system providing all the capabilities of the autoflex series...

 Open the catalog to page 3
Brochure autoflex-speed 05-2010 (270289)-4

Harnessing the Power of Innovation The autoflex speed family of products encompasses numerous technology advances that provide researchers with: Unmatched analytical speed using smartbeam™-II, a 1 kilohertz laser and system electronics for intensive or high throughput applications. The MALDI customized smartbeam-II technology is exclusively developed, manufactured and maintained by Bruker for unsurpassed MALDI results. Expanded mass range capabilities to handle intact proteins and molecules such as large polymers. Superb broadband mass resolution and mass accuracy through proprietary PAN™ technology....

 Open the catalog to page 4
Brochure autoflex-speed 05-2010 (270289)-5

Reliable and Efficient Protein Analysis MALDI based mass spectrometers have been used for many years as a standard in protein and peptide analysis, particularly for proteomics research. MALDI-TOF spectrum of intact carbonic anhy drase (CA) in sinapinic acid matrix determines the molecular weight. autoflex speed TOF/TOF systems provide information-rich protein sequencing known as Top Down Sequencing (EdmassTM, TDS) whereby the N- and C-terminal amino acids from proteins or peptides are analyzed directly. This capability can be extremely useful when analyzing known proteins such as biotherapeutics....

 Open the catalog to page 5
Brochure autoflex-speed 05-2010 (270289)-6

Molecular Tissue Imaging One of the most exciting recent developments in MALDI-TOF is the technology to generate images of individual molecules in tissue sections. This has the potential to revolutionize the discovery of protein targets associated with disease or treatment prognosis. MALDI imaging can also be used to monitor the distributions of lipids, drugs or their metabolites throughout the tissue without the need for labeling. With its kHz speed and 20-50 µm image resolution, the autoflex speed series was specifically optimized to deliver outstanding results in truly High Definition MALDI...

 Open the catalog to page 6
Brochure autoflex-speed 05-2010 (270289)-7

Glycoprotein and Glycan Analyses High molecular weight proteins Turning analysis of the complex into routine Analysis of polymers and large proteins has always been challenging for mass spectrometry. The need for analysis of these molecules has even increased with the development of Biotherapeutics that often contain glycans or are PEGylated. To address these challenges, the autoflex speed has been developed with a number of enhancements that generate convincing results. Glycopeptide analysis in one hit N-linked glycopeptide from the heavy chain of a monoclonal antibody (right). The MALDI-TOF/TOF...

 Open the catalog to page 7
Brochure autoflex-speed 05-2010 (270289)-8

Lipid Analysis and Microorganism Identification Bruker‘s unique TLC-MALDI solution hyphenates thin-layer chromatography (TLC) and MALDI-TOF MS extending the MALDI productivity to lipid profiling, herbals, cosmetics and food analysis. The MALDI Biotyper for identification and classification of microorganisms is a revolutionary approach to definitive identification and speciation of microorganisms. TLC plates can be coated in MALDI matrix within a few minutes permitting the molecular high resolution readout of entire TLC lanes. Molecular TLC-images or chromatograms are generated by dedicated software...

 Open the catalog to page 8
Brochure autoflex-speed 05-2010 (270289)-9

Polymer Analysis Applications in the field of synthetic polymers require equally good performance in both, small to medium mass range as well as high mass analysis. The autoflex speed series is well prepared for either of these tasks: Being equipped with the latest FlashDetector technology, the instrument provides outstanding resolution (R>26,000) and mass accuracy (≤ 2 ppm) in reflectron mode to address the complexity of e.g. Outstanding performance in high molecular weight measurement. complex co-polymer samples. Due to its real on-axis detector design, operating the system in linear mode allows...

 Open the catalog to page 9
Brochure autoflex-speed 05-2010 (270289)-10

Technical Specifications Increased efficiency in MALDI-TOF (/TOF) 1 kHz smartbeam-II laser technology enables ultra-high data acquisition speed. Laser focus diameters down to 10 µm for high spatial resolution imaging without pixel overlap. Wide mass range resolving power up to 26,000 due to proprietary PAN™ technology. FlashDetector™ combined with new 4 GHz digitizer provides 2 ppm mass accuracy for highest confidence. MALDI Perpetual™ Ion Source with laser-based self-cleaning in minutes. Its push-button concept for removing sample and matrix debris is indispensable for kHz operation. Compass...

 Open the catalog to page 10

All Bruker Daltonics Inc. catalogs and technical brochures

  1. neofleX™

    12  Pages

  2. timsOmniTM

    20  Pages

Archived catalogs

  1. Toxtyper

    6  Pages

  2. impact HD

    12  Pages

  3. solarix XR

    12  Pages

  4. SIGIS II

    2  Pages

  5. VeroTect

    4  Pages

  6. µRAID

    4  Pages

  7. MM2

    6  Pages

  8. RAID M100

    6  Pages

  9. RAID S2

    6  Pages

  10. RAID XP

    4  Pages

  11. RAID AFM

    4  Pages

  12. pTD

    2  Pages

  13. DE-tector

    6  Pages

  14. ImagePrep

    4  Pages

  15. micrOTOF II

    8  Pages

  16. impact II

    12  Pages

  17. EVOQ

    6  Pages

  18. maxis II

    12  Pages

  19. ProteinScape

    8  Pages

  20. MALDI Imaging

    16  Pages

  21. MBT Pharma

    8  Pages

  22. MBT BTS US

    2  Pages

  23. MBT SMART IVD

    4  Pages

  24. MBT Pilot RUO

    4  Pages

  25. timsTOF Pro

    6  Pages

  26. timsTOF™

    8  Pages

  27. TASQ Software

    4  Pages

  28. Metabolomics

    8  Pages

  29. spotOn™

    4  Pages

  30. Toxtyper

    8  Pages

  31. CMC-assist

    2  Pages

  32. EVOQ - 2014

    6  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.