impact HD
12Pages

{{requestButtons}}

Catalog excerpts

impact HD - 1

impact HD Get the full picture first time Innovation with Integrity

Open the catalog to page 1
impact HD - 2

Sensational Capabilities of impact HD Optimize your LC-MS methods without compromising performance: impact HD delivers the full range of specified performance parameters simultaneously to solve your analytical challenges. The Ultra-High Resolution (UHR) TOF technology pioneered by Bruker once again defines the standards of what can be achieved using accurate mass LC-MS/MS. New innovations in time-of-flight instrumentation are now available in a robust and market-leading benchtop system. Your Success with impact HD High-Definition Technology Instant Expertise™ Software Enhanced dynamic range...

Open the catalog to page 2
impact HD - 3

Routinely Identify More – All Day, Every Day Dynamic range – five orders of magnitude 50 GBit/sec sampling technology enables high definition data acquisition on an LC timescale Greatly increased robustness to sample variation allowing reduced sample pretreatment especially desirable in high throughput quantitative applications. Definitive trace analysis from complex, high-background matrices makes your analytical work more productive. Increased dynamic range, excellent robustness, and full sensitivity gives you the deepest insight into your sample and what might be hiding underneath....

Open the catalog to page 3
impact HD - 4

More Dynamic Range, More Accurate, More Confidence Enhanced sensitivity through broad mass transfer impact HD with 10 bit digitizer hrEIC of 60 pesticides from m/z 70 up to 900 at 2.5 ppm cone. 3-4 x higher dynamic range from 10 bit Provides highest 50 GBit/sec sampling speeds and while maintaining high Much higher dynamic range in analyte concentration attainable 100 fg absolute reserpine with ionbooster Patented dual Ion-Funnel: Triple-quad like sensitivity

Open the catalog to page 4
impact HD - 5

Flight Tube with in-flight focussing and dual stage reflector for Full Sensitivity Resolution (FSR) Novel high-definition 10 bit detection system Broad mass transfer Quadrupole CID cell Much higher dynamic range in concentration reachable Intens. x107 In-spectrum dynamic range @ real LC speed – don’t miss low abundant peaks.

Open the catalog to page 5
impact HD - 6

Solving the “Omics Puzzle“ – from Label-Free Discovery to Targeted Proteomics ... Robust profiling of large omics sample sets in one run acquisitions LC peaks in QC sample remain constant in intensity Instant Expertise: Fast + smart is better than just fast QC samples run interspersed over 150 injections of complex coffee metabolomics samples Intens. x106 ~150 Injections in between QC Injection No.147 The Instant Expertise method, based on the IDAS and RT2 strategies (see App-Note MT-81) automatically adjusts the number and speed of MS/MS acquisitions within a fixed MS cycle time to obtain...

Open the catalog to page 6
impact HD - 7

... and Metabolomics Validation Studies Easy identification of unknown metabolites measured simulated Straight forward unknown ID: Perfect match even of 3rd isotope. Mass accuracy Isotopic fidelity High sensitivity even at low mass range in MS and MS/MS spectra Combined in simple software: SmartFormula3D + FragmentExplorer Learn more about unknown ID in Metabolomics research leveraged by HD performance: App-Note LCMS-79. Quantification: Triple quad-like linearity by HD performance Targeted proteomics: Quantify all candidates in one run with DIA acquisition modes Ceruloplasmin peptide....

Open the catalog to page 7
impact HD - 8

Qualitative and Quantitative Drug Metabolism Characterization Metabolite Detection Metabolite Detect software compares the data file for the drug (in this case t60) with the corresponding control sample. Auto MS/MS Spectrum A base peak chromatogram of the difference is created allowing metabolites m/z 354, 212 and even 392 to be easily observed. Drug and Metabolite Profiles Integration is carried out on the EIC for the measured m/z of each metabolite +/- 0.005 Da. Plotting the ratio of metabolite to internal standard (MIS) vs. time produces the metabolite profiles. Half-life and clearance...

Open the catalog to page 8
impact HD - 9

Your Partner in Biopharmaceutical QC Comprehensive capabilities for biological therapeutics screening, characterization and confirmation. > 96% Sequence Coverage of Panitumumab Compatible with Biopharma Compass for seamless transition from method development to fully automated control and reporting of critical quality attributes. Broadband transmission and wide dynamic range for effective screening and quantitation of released glycans and small molecule impurities. High speed MS/MS acquisition and large dynamic range enable the acquisition of high coverage peptides maps and associated...

Open the catalog to page 9
impact HD - 10

One-Shot Full Picture of the Sample ... Pyriproxyfen Chlorpyriphos Multi-target screening on 10 ppb level in orange matrix Pyraclostrobin Tolyfluanid Kresoxim-methyl Tebuconazole Penconazole Triadimenol I+II Fenhexamid Linuron Boscalid Fludioxonil (NH4) Dimethomorph Peak 2 Methoxyfenozide Fragm 313 Chlorpropham Fragm 172 Myclobutanil Butocarboxim Fragm 75 Aldicarb Fragm 116 High-resolution Extracted Ion Chromatogram (hrEIC) identifying 60 pesticides in a single LC-TOF run. All analytes across the mass range 70 to 900 m/z are detected with highest sensitivity maintaining full resolution at...

Open the catalog to page 10
impact HD - 11

... for Rapid Profiling and Screening of Unknowns Pilots the sample to target the correct quantitation assay, saving time and multiple re-analysis costs Enables rapid reaction to emerging challenges in food safety and doping even before reference standards are available Facilitates retrospective in-silico analysis for post-hoc identification of true unknown contaminants Accurate mass screening databases for Food Testing, Forensics and Drugs of Abuse Food / Water/ Forensic sample One shot qual / quant analysis with no method development MS, Total Ion CID, MSMS Processing with high quality...

Open the catalog to page 11
impact HD - 12

Dynamic Source Configuration In addition to the ESI sources, impact HD supports a wide range of source options from Bruker and third-party vendors, all switchable within seconds. CaptiveSpray™ nanoBooster CaptiveSpray nanoBooster is the proteomics ion source that brings your MS to the next performance level – The operation is as easy as electrospray can be. The nanoBooster enables Glycoanalysis, supercharging and pushes up ID rates. Atmospheric Pressure Photo Ionization is used for less polar or non-polar molecules that can not be ionized in either ESI or APCI. ionBooster™ The ionBooster...

Open the catalog to page 12

All Bruker Daltonics Inc. catalogs and technical brochures

  1. CMC-assist

    2 Pages

  2. Toxtyper

    8 Pages

  3. spotOn™

    4 Pages

  4. Metabolomics

    8 Pages

  5. timsTOF™

    8 Pages

  6. timsTOF Pro

    6 Pages

  7. MBT BTS US

    2 Pages

  8. MBT Pharma

    8 Pages

  9. MALDI Imaging

    16 Pages

  10. ProteinScape

    8 Pages

  11. maxis II

    12 Pages

  12. EVOQ

    6 Pages

  13. impact II

    12 Pages

  14. micrOTOF II

    8 Pages

  15. ImagePrep

    4 Pages

  16. DE-tector

    6 Pages

  17. pTD

    2 Pages

  18. RAID AFM

    4 Pages

  19. RAID XP

    4 Pages

  20. RAID S2

    6 Pages

  21. RAID M100

    6 Pages

  22. MM2

    6 Pages

  23. µRAID

    4 Pages

  24. VeroTect

    4 Pages

  25. SIGIS II

    2 Pages

  26. solarix XR

    12 Pages

  27. Toxtyper

    6 Pages

Archived catalogs

  1. EVOQ - 2014

    6 Pages