MALDI Sepsityper ® MALDI Biotyper® For Direct Microorganism Identification from Positive Blood Culture Bottles Innovation with Integrity
Open the catalog to page 1When every minute counts ... Bruker’s MALDI Sepsityper solution provides a rapid, highly accurate microbial identification directly from a positive blood culture. Bruker‘s MALDI Sepsityper enables identification of gram-negative bacteria, gram-positive bacteria and yeast from positive blood cultures within 30 minutes. Using the MALDI Sepsityper solution can reduce the turn around time, provided by traditional positive blood culture identification work flows, up to 24 hours by eliminating the time consuming step of culturing the microorganisms. MALDI Sepsityper enables faster results, which physicians...
Open the catalog to page 2References [1] Kok, J., et al., Identification of bacteria in blood culture broths using matrix-assisted laser desorptionionization Sepsityper and time of flight mass spectrometry. PLoS One, 2011. 6(8): p. e23285. [2] Schubert, S., et al., Novel, Improved Sample Preparation for Rapid, Direct Identification from Positive Blood Cultures Using Matrix-Assisted Laser Desorption/Ionization Time-of-Flight (MALDI-TOF) Mass Spectrometry. The Journal of Molecular Diagnostics, 2011. 13(6): p. 701-706. [3] Yan, Y., et al., Improved identification of yeast species directly from positive blood culture media...
Open the catalog to page 3References [14] Jamal, W., R. Saleem, and V.O. Rotimi, Rapid identification of pathogens directly from blood culture bottles by Bruker matrix-assisted laser desorption laser ionization-time of flight mass spectrometry versus routine methods. Diagn Microbiol Infect Dis, 2013. 76(4): p. 404-8. [15] Nonnemann, B., M. Tvede, and T. Bjarnsholt, Identification of pathogenic microorganisms directly from positive blood vials by matrix-assisted laser desorption/ionization time of flight mass spectrometry. Apmis, 2013. 121(9): p. 871-7. [16] Tadros, M. and A. Petrich, Evaluation of MALDI-TOF mass spectrometry...
Open the catalog to page 4Positive Blood Culture Bottle Harvest 1 ml blood culture liquid in an Eppendorf tube; 1 min Add 200 ml Lysis Buffer and mix; 10 (± 5) sec Centrifuge (2 min., 13.000 rpm) discard supernatant; 2 min Add 1 ml Washing Buffer and mix; 1.5 min Centrifuge (1 min., 13.000 rpm) discard supernatant; 1 min Proceed with sample preparation Order information The MALDI Sepsityper Kit contains all reagents and consumables required for isolation of 50 positive blood culture samples. Storage at room temperature. Part-No. 8270170 MALDI Sepsityper Kit For research use only. Not for use in diagnostic procedures....
Open the catalog to page 5[email protected] www.bruker.com to change specifications without notice. © BDAL 04-2015, 1837305 Bruker Daltonics is continually improving its products and reserves the right MALDI Biotyper ® and MALDI Sepsityper ® are registered trademarks of Bruker Daltonik GmbH in the European Union and USA
Open the catalog to page 620 Pages
20 Pages
12 Pages
20 Pages
6 Pages
6 Pages
4 Pages
12 Pages
20 Pages
10 Pages
12 Pages
2 Pages
4 Pages
4 Pages
6 Pages
6 Pages
6 Pages
6 Pages
4 Pages
4 Pages
2 Pages
6 Pages
4 Pages
8 Pages
12 Pages
6 Pages
12 Pages
8 Pages
6 Pages
12 Pages
6 Pages
4 Pages
8 Pages
8 Pages
16 Pages
8 Pages
2 Pages
2 Pages
4 Pages
4 Pages
4 Pages
4 Pages
8 Pages
6 Pages
6 Pages
8 Pages
4 Pages
8 Pages
8 Pages
4 Pages
16 Pages
8 Pages
2 Pages
2 Pages
12 Pages
12 Pages
6 Pages