X-RAY DIFFRACTION & SCATTERING D8 ADVANCE Fine-tuned to peak performance Innovation with Integrity
Open the catalog to page 1D8 ADVANCE – simply ingenious D8 ADVANCE solutions are the recognized first choice when it comes to X-ray powder diffraction and scattering. The proven instrument and software design allows for the easy combination and optimization of components to measure first-class and reliable data for any application. D8 ADVANCE solutions are based on more than half a century of experience in development, manufacturing, and application, and they represent an investment asset that will safely enable current and future analytical tasks with an ever-evolving range of accessories. The D8 ADVANCE offers fully...
Open the catalog to page 3DAVINCI Design – proven ease-of-use Leonardo da Vinci contributed ingenious suggestions for the interaction of humans and machines, serving as inspiration for a distinctive X-ray diffractometer operation approach known as “DAVINCI Design”. The D8 ADVANCE with DAVINCI Design achieves a perfect blend of user-friendly interface, guidance, and intuition, making it accessible to all users and applications. The heart of DAVINCI Design is the software plug-in DIFFRAC.DAVINCI. Dependent on sample properties and the analytical task at hand, every user can quickly and easily optimize the D8 ADVANCE configuration...
Open the catalog to page 4illil, Phase Identification & Quantification Crystal Structure Determination & Refinement H Microstructure Analysis pdf Pair Distribution Function Analysis Stress Analysis Texture Analysis t:£> Grazing Incidence Diffraction X-ray Reflectometry Small Angle X-ray Scattering w< Wide Angle X-ray Scattering The D8 ADVANCE is suitable for all X-ray powder diffraction and scattering applications. It can accommodate X-ray tubes ranging from Cr to Ag, with power options including the 1 kW ECO environmentally friendly generator or the standard 3 kW generator. The TWIN-TWIN geometry allows for fully automatic...
Open the catalog to page 7Parallel Beam Divergent Beam Variable Slit Equatorial Soller Collimator TWIN–TWIN – one for all Whatever the sample type, the D8 ADVANCE delivers the best possible data quality in the shortest time. Whether it’s ideal powders, irregularly shaped samples, or thin films, the TWIN–TWIN optics allow automatic switching between divergent and parallel beam geometries to obtain maximum peak intensity and resolution. Any sample can be measured using either geometry, and back-to-back measurements can be programmed to get the best of all setups. With the AUTOCHANGER option, up to 90 different samples can...
Open the catalog to page 8- Motorized anti-scatter slit - Equatorial 0.2° Soller collimator - Fully software controlled - Motorized divergence slit for Bragg-Brentano geometry - Gobel mirror for parallel-beam geometry - Fully software controlled Dynamic Beam Optimization - Combination of a Motorized Antiscatter Screen (MASS), variable slit and variable detector field-of-view (LYNXEYE and EIGER2 R families) - Full software-synchronization with 20 - No beam cropping at higher angles - Background-free data at all angles 20 - Exceptionally good data quality at very low angles < 1° 20 - Significantly enhanced lower limits...
Open the catalog to page 9For materials with low absorption coefficients and environmental sensitivity or for advanced applications like structure determination, small angle X-ray scattering (SAXS), and pair distribution function (PDF) analysis, measurements in transmission geometry are the preferred choice. Samples can be solids, powders, or suspensions - prepared in capillaries, between foils, or measured as-is. These applications often benefit from tailored solutions with dedicated optics that focus on the detector, including focusing Gobel mirrors or Johansson Ka-i monochromators.They may require high X-ray energies...
Open the catalog to page 101) Lorem ipsum dolor 2) Sit amet, consectetuer 3) Adipiscing elit 4) Proin a magna 5) Cras vehicula 6) Mauris pretium 7) Tincidunt id 8) Adipiscing elit 1) Cu X-ray tube 2) Primary TWIN optics 3) Motorized Air Scatter Screen 4) AUTOCHANGER 5) Secondary TWIN optics 6) LYNXEYE XE-T detector Maximum sample throughput at highest data quality For applications ranging from quality control of cathode materials to mineral exploration, the key is sample throughput. This applies to research and development, process and quality control, as well as to service laboratories and multi-user facilities. With...
Open the catalog to page 111) Lorem ipsum dolor 2) Sit amet, consectetuer 3) Adipiscing elit 4) Proin a magna 5) Cras vehicula 6) Mauris pretium 7) Tincidunt id 1) X-ray tube elit 8) Adipiscing 2) Variable slit 3) MTC chamber 4) Motorized Air Scatter Slit 5) LYNXEYE XE-T detector Measurement beyond ambient conditions The performance of a material is significantly influenced by the environmental conditions it is exposed to, whether it involves exploring the polymorphic landscape of active pharmaceutical ingredients, subjecting refractory materials to high temperatures in an iron furnace, or repeatedly charging and discharging...
Open the catalog to page 12Modular chamber design that can be reconfigured for: TC TRANSMISSION - From room temperature up to 1,000 °C - Excellent sample temperature uniformity - Free-sliding oven housing for easy exchange of samples or ambient data collection Modular dome stage with X-ray transparent Be dome that can be reconfigured for: - Thin film samples (-180 to 1,100 °C) - Electrochemical cell designed by battery experts for reflection and transmission - Flexible pouch cell holder for various sizes - Fully software integrated potentiostat
Open the catalog to page 13D8 ADVANCE Plus – resolution at your command Phase Identification & Quantification Crystal Structure Determination & Refinement Microstructure Analysis Pair Distribution Function Analysis Stress Analysis Texture Analysis Grazing Incidence Diffraction X-ray Reflectometry s Small Angle X-ray Scattering Wide Angle X-ray Scattering High-Resolution X-ray Diffraction Ultra Small Angle X-ray Scattering Grazing Incidence Small Angle X-ray Scattering Micro Diffraction With optics like the TRIO and PATHFINDER Plus, the D8 ADVANCE Plus is equipped to handle samples ranging from ceramic sputtering targets...