1. Catalogs
  2. Bruker Optics
  3. D8 ADVANCE - Fine-tuned to peak performance

D8 ADVANCE - Fine-tuned to peak performance

D8 ADVANCE - Fine-tuned to peak performance
1 / 32 PagesView full catalog

D8 ADVANCE - Fine-tuned to peak performance

Product catalog summary
D8 ADVANCE Overview
The D8 ADVANCE is a versatile and reliable solution for X-ray powder diffraction and scattering. It allows automatic switching between up to six instrument geometries and various sample stages, optimized for diverse tasks. Key components include TWIN, TRIO, PATHFINDER Plus, and the LYNXEYE and EIGER2 R detector families.
DAVINCI Design
The DAVINCI Design focuses on user-friendly operation, enabling easy configuration optimization through DIFFRAC.WIZARD software. It features motorized X-ray optics for seamless beam path switching and real-time component recognition.
Instrument Capabilities
The D8 ADVANCE supports various X-ray tubes and power options, including an eco-friendly 1 kW generator. It features TWIN–TWIN geometry for automatic beam geometry switching and the LYNXEYE XE-T detector for superior sample fluorescence filtering.
Dynamic Beam Optimization
This feature reduces air and instrument scattering, allowing data acquisition over a wide angle range. It includes a motorized anti-scatter screen and variable detector field of view, enhancing data quality and detection limits.
Transmission Geometry
Preferred for materials with low absorption coefficients, the D8 ADVANCE supports transmission geometry with tailored optics and high X-ray energies, suitable for advanced applications like small angle X-ray scattering.
Sample Throughput
The AUTOCHANGER enhances sample throughput, accommodating up to 90 samples and supporting multiple scattering geometries without user intervention, ideal for quality control and research applications.
Environmental Conditions
The D8 ADVANCE can replicate various environmental conditions for in-situ or operando studies, offering a Modular Temperature Chamber (MTC) and an electrochemical cell for battery research.
D8 ADVANCE Plus
Equipped with TRIO and PATHFINDER Plus optics, it handles a wide range of samples and applications, including stress and texture analysis with the Compact Cradle Plus and high-resolution diffraction with the EIGER2 R detector.
Grazing Techniques
The system supports grazing incidence diffraction and X-ray reflectometry for surface-sensitive measurements, providing exceptional accuracy over a wide angular range.
Introduction to XRR and GID Techniques
X-ray Reflectivity (XRR) measures the thickness, roughness, and density of films up to 150 nm, providing comprehensive information about the entire film stack.
Importance of X-ray Mirrors
High-quality X-ray mirrors enhance data quality and measurement speed for Grazing Incidence Diffraction (GID) and XRR. The TRIO optic with integrated mirror and 2-bounce monochromator is available for high-resolution XRR.
Characterization of Epitaxial Films
Device optimization for applications like III-V power converters requires careful characterization of nanometer-scale single crystal thin films, facilitated by the D8 ADVANCE Plus.
Residual Stress Analysis
Mapping residual stresses is crucial for assessing material structural integrity. The Compact UMC stage supports samples up to 2 kg, and the EIGER2 R detector allows rapid 2D data collection.
Texture Analysis
Understanding material texture is vital for performance in applications like sheet metals. The D8 ADVANCE with Compact Cradle Plus enables texture measurements, reducing measurement time.
Micro-XRD Applications
Micro-XRD requires high spatial resolution, achieved with a small diameter, high flux density X-ray beam. The D8 ADVANCE is ideal for micro-XRD applications.
XRD2 for Small Sample Volumes
Large 2D detectors like the EIGER2 R enhance measurement speeds for applications like residual stress and texture analyses.
Nanoscale Structure Analysis
Small Angle X-ray Scattering (SAXS) and Wide Angle X-ray Scattering (WAXS) provide information on nano-scale structures, with the D8 ADVANCE extending capabilities to Ultra Small Angle X-ray Scattering (USAXS).
Instrument Safety and Compliance
The D8 ADVANCE complies with EU standards for electromagnetic compatibility and X-ray safety, verified by the German National Metrology Institute (PTB).
Software and Analysis Tools
The D8 ADVANCE offers various software tools for data analysis, supporting a wide range of applications from phase identification to texture analysis.
Specifications
  • Geometries: Vertical goniometer with Theta/Theta or Theta/2Theta configurations.
  • Measuring Diameter: Predefined at 500, 560, and 600 mm, with intermediate settings available.
  • Angular Range: Maximum usable range from –110° to 168° 2θ.
  • Angle Positioning: Utilizes stepper motors with optical encoders.
  • Angular Speed: Maximum speed of 20°/s, depending on accessories.
  • Accuracy: ± 0.01° across the entire angular range.
  • X-ray Wavelengths: Options include Cr, Co, Cu, Mo, Ag, with others available on request.
  • X-ray Generator Options: Available in 1 kW (ECO) or 3 kW.
  • Detector Options: SSD 160-2, LYNXEYE-2, LYNXEYE XE-T, EIGER2 R 250K, EIGER2 R 500K.
Physical and Power Specifications
  • Dimensions: 186.8 cm (h) x 113.5 cm (d) x 130.0 cm (w).
  • Weight: Minimum 770 kg, depending on configuration.
  • Power Supply: Single phase (208 – 240 V) or three phase (120 V, 230 V, 240 V; 47 – 63 Hz).
  • Max Power Consumption: 6.5 kVA.
  • Cooling Water Supply: 1 kW (ECO) requires no external cooling; 3 kW requires a minimum of 4 l/min at 4 – 7.5 bar, 10 – 25°C.
Connectivity and Patents
  • Computer Connection: PC connected via LAN interface.
  • Patents: Includes several patents related to X-ray technology and data correction algorithms.
See more

Catalog excerpts

D8 ADVANCE - Fine-tuned to peak performance -1

X-RAY DIFFRACTION & SCATTERING D8 ADVANCE Fine-tuned to peak performance Innovation with Integrity

 Open the catalog to page 1
D8 ADVANCE - Fine-tuned to peak performance -3

D8 ADVANCE – simply ingenious D8 ADVANCE solutions are the recognized first choice when it comes to X-ray powder diffraction and scattering. The proven instrument and software design allows for the easy combination and optimization of components to measure first-class and reliable data for any application. D8 ADVANCE solutions are based on more than half a century of experience in development, manufacturing, and application, and they represent an investment asset that will safely enable current and future analytical tasks with an ever-evolving range of accessories. The D8 ADVANCE offers fully...

 Open the catalog to page 3
D8 ADVANCE - Fine-tuned to peak performance -4

DAVINCI Design – proven ease-of-use Leonardo da Vinci contributed ingenious suggestions for the interaction of humans and machines, serving as inspiration for a distinctive X-ray diffractometer operation approach known as “DAVINCI Design”. The D8 ADVANCE with DAVINCI Design achieves a perfect blend of user-friendly interface, guidance, and intuition, making it accessible to all users and applications. The heart of DAVINCI Design is the software plug-in DIFFRAC.DAVINCI. Dependent on sample properties and the analytical task at hand, every user can quickly and easily optimize the D8 ADVANCE configuration...

 Open the catalog to page 4
D8 ADVANCE - Fine-tuned to peak performance -7

illil, Phase Identification & Quantification Crystal Structure Determination & Refinement H Microstructure Analysis pdf Pair Distribution Function Analysis Stress Analysis Texture Analysis t:£> Grazing Incidence Diffraction X-ray Reflectometry Small Angle X-ray Scattering w< Wide Angle X-ray Scattering The D8 ADVANCE is suitable for all X-ray powder diffraction and scattering applications. It can accommodate X-ray tubes ranging from Cr to Ag, with power options including the 1 kW ECO environmentally friendly generator or the standard 3 kW generator. The TWIN-TWIN geometry allows for fully automatic...

 Open the catalog to page 7
D8 ADVANCE - Fine-tuned to peak performance -8

Parallel Beam Divergent Beam Variable Slit Equatorial Soller Collimator TWIN–TWIN – one for all Whatever the sample type, the D8 ADVANCE delivers the best possible data quality in the shortest time. Whether it’s ideal powders, irregularly shaped samples, or thin films, the TWIN–TWIN optics allow automatic switching between divergent and parallel beam geometries to obtain maximum peak intensity and resolution. Any sample can be measured using either geometry, and back-to-back measurements can be programmed to get the best of all setups. With the AUTOCHANGER option, up to 90 different samples can...

 Open the catalog to page 8
D8 ADVANCE - Fine-tuned to peak performance -9

- Motorized anti-scatter slit - Equatorial 0.2° Soller collimator - Fully software controlled - Motorized divergence slit for Bragg-Brentano geometry - Gobel mirror for parallel-beam geometry - Fully software controlled Dynamic Beam Optimization - Combination of a Motorized Antiscatter Screen (MASS), variable slit and variable detector field-of-view (LYNXEYE and EIGER2 R families) - Full software-synchronization with 20 - No beam cropping at higher angles - Background-free data at all angles 20 - Exceptionally good data quality at very low angles < 1° 20 - Significantly enhanced lower limits...

 Open the catalog to page 9
D8 ADVANCE - Fine-tuned to peak performance -10

For materials with low absorption coefficients and environmental sensitivity or for advanced applications like structure determination, small angle X-ray scattering (SAXS), and pair distribution function (PDF) analysis, measurements in transmission geometry are the preferred choice. Samples can be solids, powders, or suspensions - prepared in capillaries, between foils, or measured as-is. These applications often benefit from tailored solutions with dedicated optics that focus on the detector, including focusing Gobel mirrors or Johansson Ka-i monochromators.They may require high X-ray energies...

 Open the catalog to page 10
D8 ADVANCE - Fine-tuned to peak performance -11

1) Lorem ipsum dolor 2) Sit amet, consectetuer 3) Adipiscing elit 4) Proin a magna 5) Cras vehicula 6) Mauris pretium 7) Tincidunt id 8) Adipiscing elit 1) Cu X-ray tube 2) Primary TWIN optics 3) Motorized Air Scatter Screen 4) AUTOCHANGER 5) Secondary TWIN optics 6) LYNXEYE XE-T detector Maximum sample throughput at highest data quality For applications ranging from quality control of cathode materials to mineral exploration, the key is sample throughput. This applies to research and development, process and quality control, as well as to service laboratories and multi-user facilities. With...

 Open the catalog to page 11
D8 ADVANCE - Fine-tuned to peak performance -12

1) Lorem ipsum dolor 2) Sit amet, consectetuer 3) Adipiscing elit 4) Proin a magna 5) Cras vehicula 6) Mauris pretium 7) Tincidunt id 1) X-ray tube elit 8) Adipiscing 2) Variable slit 3) MTC chamber 4) Motorized Air Scatter Slit 5) LYNXEYE XE-T detector Measurement beyond ambient conditions The performance of a material is significantly influenced by the environmental conditions it is exposed to, whether it involves exploring the polymorphic landscape of active pharmaceutical ingredients, subjecting refractory materials to high temperatures in an iron furnace, or repeatedly charging and discharging...

 Open the catalog to page 12
D8 ADVANCE - Fine-tuned to peak performance -13

Modular chamber design that can be reconfigured for: TC TRANSMISSION - From room temperature up to 1,000 °C - Excellent sample temperature uniformity - Free-sliding oven housing for easy exchange of samples or ambient data collection Modular dome stage with X-ray transparent Be dome that can be reconfigured for: - Thin film samples (-180 to 1,100 °C) - Electrochemical cell designed by battery experts for reflection and transmission - Flexible pouch cell holder for various sizes - Fully software integrated potentiostat

 Open the catalog to page 13
D8 ADVANCE - Fine-tuned to peak performance -14

D8 ADVANCE Plus – resolution at your command Phase Identification & Quantification Crystal Structure Determination & Refinement Microstructure Analysis Pair Distribution Function Analysis Stress Analysis Texture Analysis Grazing Incidence Diffraction X-ray Reflectometry s Small Angle X-ray Scattering Wide Angle X-ray Scattering High-Resolution X-ray Diffraction Ultra Small Angle X-ray Scattering Grazing Incidence Small Angle X-ray Scattering Micro Diffraction With optics like the TRIO and PATHFINDER Plus, the D8 ADVANCE Plus is equipped to handle samples ranging from ceramic sputtering targets...

 Open the catalog to page 14

All Bruker Optics catalogs and technical brochures

  1. GenoXtract®

    2  Pages

  2. LUMOS II ILIM

    8  Pages

  3. BRAVO

    12  Pages

  4. MATRIX-MF II

    2  Pages

  5. MATRIX-F II

    16  Pages

  6. MPA III

    7  Pages

  7. CONFOCHECK

    8  Pages

  8. INVENIO

    12  Pages

  9. ALPHA II

    12  Pages

  10. TANGO II

    5  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About MedicalExpo