
CXJ • LUMOS II FT-IR Imaging Microscope LUMOS II features: ■ Superior focal-plane array (FPA) technology ■ High-definition spectroscopic and visual data ■ Ultrafast data acquisition in FPA imaging ■ FT-IR imaging in ATR/transmission/reflec-tion ■ Fully automated measurements in all modes ■ TE-MCT detector as standard ■ Software guided measurements ■ Analyze samples up to 40 mm in height ■ Huge field of view at submicron resolution ■ All hardware motorized and software controlled for your convenience ■ Complies to cGMP, Pharmacopoeias and FDA 21 CFR part 11 ■ Automated OQ/PQ/pharmacopeia tests ■ Always reliable performance with PermaSure+ What is the LUMOS II? The LUMOS II is as an easy-to-use, stand-alone FT-IR imaging microscope with peak performance in any measurement mode. Whether it is transmission, reflection or attenuated total reflectance (ATR), the LUMOS II is always the right choice. What are the benefits of FT-IR microscopy? Conventional microscopy is clearly one of the most widespread analytical techniques in research, forensics, failure analysis, life-science and electronics. Combine it with FT-IR and you get a precise and even more powerful tool for a comprehensive microanalysis. Detect and immediately characterize tiny particles, product defects or tissue anomalies. Why go for FPA imaging? Focal Plane Array (FPA) detectors record IR data at ultra high speed with maximum spectral detail. They are the ultimate choice for FT-IR imaging and recording large amounts of data in minimal time. We call it true imaging. Why? Because it is so straightforward and offers all users great benefits in spectral analysis. It is applicable in all measurement modes and offers almost unlimited possibilities. Innovation with Integrity
Open the catalog to page 1Product Highlights■ FPA imaging LUMOS II offers exclusive focal-plane array (FPA) imaging technology. Access superb spatial resolution, peak sensitivity and collect 1024 spectra in a single scan. Applications ■ Particle identification ■ Root cause and failure analysis ■ Quality control of products The hardware is fully motorized and software controlled. Change measurement modes and switch detectors in seconds with a mouse-click. ■ Detector The standard TE-MCT detector requires no liquid nitrogen and still delivers high sensitivity for small samples. Equip up to three detectors (incl. FPA). Software...
Open the catalog to page 22 Pages
2 Pages
8 Pages
8 Pages
8 Pages
12 Pages
2 Pages
16 Pages
7 Pages
8 Pages
12 Pages
12 Pages
5 Pages