894434 | Version 09/2017 | Print 09/2017 | © Christian Bürkert GmbH & Co. KG Bürkert Fluid Control Systems Christian-Bürkert-Straße 13-17 74653 Ingelfingen Deutschland Tel.: +49 (0) 7940/10-0 Fax: +49 (0) 7940/10-91 204 [email protected] www.buerkert.de Selection Chart Solenoid valves Brochures Water vapour pressure table Pressure conversion Temperature conversion Kinematic viscosity Flow rates Plastics for bodies Seal & d

 Open the catalog to page 1
Selection Chart Solenoid valves-2

Seal material Diaphragm material Media (0 c E <3 « c ■£ <s^ Direct-acting plunger valves Spring coupled Servo-assisted diaphragm valves 6213EV 6281EV 0290 5282 Flange version in grey cast iron, fixed coupled Flange version in grey cast iron, pilot media separated PIC = Push-in connection I SFB= Specific flange Burkert □ Universal for gases + fluids S = Standard | A = On request |N = Not available | 1 = plastic version: Type 0142 O Gas and/or steam applications only as seal material |x = suitable | o = partially suitable | - = not suitable / suitable for water applications

 Open the catalog to page 2
Selection Chart Solenoid valves-3

Reference: saturated vapour Water vapour pressure table

 Open the catalog to page 3
Selection Chart Solenoid valves-4

Pressure conversion

 Open the catalog to page 4
Selection Chart Solenoid valves-5

Temperature conversion

 Open the catalog to page 5
Selection Chart Solenoid valves-6

The maximum viscosity specified in the data sheets refers to the indicated switching times. Higher viscosities can be switched, but increase the switching time. Kinematic viscosity

 Open the catalog to page 6
Selection Chart Solenoid valves-7

Coil encapsulation

 Open the catalog to page 7
Selection Chart Solenoid valves-8

Piston valve Type 6240 General: The Kv value corresponds to the water flow rate through a valve (in m3/h) at a pressure differential of 1 bar (exactly 0.98 bar) and a water temperature of 5 - 30 °C. Depending on the valve size it is often stated in l/min. Fluids: For fluids the minimum required Kv value for a valve is determined from the operating data required for the application based on the following equation, if the pressure loss is between 0.35 and 1 bar: Special case - water: For water as a medium (p = 1000 kg/m3) the formula is simplified to: Kv = Q . • Ibar \ ap Q = Volume flow...

 Open the catalog to page 8
Selection Chart Solenoid valves-10

* only seal material Seal & diaphragm materials

 Open the catalog to page 10
Selection Chart Solenoid valves-11

Product overview 01 Solenoid valves # 894492 DE # 894486 EN Pivoted armature valve 330 # 894286 DE # 894287 EN EV series solenoid valves # 894417 DE # 894418 EN Plunger solenoid valves # 894392 DE # 894393 EN

 Open the catalog to page 11

All Bürkert GmbH & Co. KG Fluid Control Systems catalogs and technical brochures

  1. Type 6240

    26  Pages

  2. 0255

    9  Pages

  3. 0142

    9  Pages

  4. 6724

    17  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.