Selection Chart Solenoid valves
11Pages

{{requestButtons}}

Catalog excerpts

Selection Chart Solenoid valves - 1

894434 | Version 09/2017 | Print 09/2017 | © Christian Bürkert GmbH & Co. KG Bürkert Fluid Control Systems Christian-Bürkert-Straße 13-17 74653 Ingelfingen Deutschland Tel.: +49 (0) 7940/10-0 Fax: +49 (0) 7940/10-91 204 info@buerkert.de www.buerkert.de Selection Chart Solenoid valves Brochures Water vapour pressure table Pressure conversion Temperature conversion Kinematic viscosity Flow rates Plastics for bodies Seal & d

Open the catalog to page 1
Selection Chart Solenoid valves - 2

Seal material Diaphragm material Media (0 c E <3 « c ■£ <s^ Direct-acting plunger valves Spring coupled Servo-assisted diaphragm valves 6213EV 6281EV 0290 5282 Flange version in grey cast iron, fixed coupled Flange version in grey cast iron, pilot media separated PIC = Push-in connection I SFB= Specific flange Burkert □ Universal for gases + fluids S = Standard | A = On request |N = Not available | 1 = plastic version: Type 0142 O Gas and/or steam applications only as seal material |x = suitable | o = partially suitable | - = not suitable / suitable for water applications

Open the catalog to page 2
Selection Chart Solenoid valves - 3

Reference: saturated vapour Water vapour pressure table

Open the catalog to page 3
Selection Chart Solenoid valves - 4

Pressure conversion

Open the catalog to page 4
Selection Chart Solenoid valves - 5

Temperature conversion

Open the catalog to page 5
Selection Chart Solenoid valves - 6

The maximum viscosity specified in the data sheets refers to the indicated switching times. Higher viscosities can be switched, but increase the switching time. Kinematic viscosity

Open the catalog to page 6
Selection Chart Solenoid valves - 7

Coil encapsulation

Open the catalog to page 7
Selection Chart Solenoid valves - 8

Piston valve Type 6240 General: The Kv value corresponds to the water flow rate through a valve (in m3/h) at a pressure differential of 1 bar (exactly 0.98 bar) and a water temperature of 5 - 30 °C. Depending on the valve size it is often stated in l/min. Fluids: For fluids the minimum required Kv value for a valve is determined from the operating data required for the application based on the following equation, if the pressure loss is between 0.35 and 1 bar: Special case - water: For water as a medium (p = 1000 kg/m3) the formula is simplified to: Kv = Q . • Ibar \ ap Q = Volume...

Open the catalog to page 8
Selection Chart Solenoid valves - 10

* only seal material Seal & diaphragm materials

Open the catalog to page 10
Selection Chart Solenoid valves - 11

Product overview 01 Solenoid valves # 894492 DE # 894486 EN Pivoted armature valve 330 # 894286 DE # 894287 EN EV series solenoid valves # 894417 DE # 894418 EN Plunger solenoid valves # 894392 DE # 894393 EN

Open the catalog to page 11

All Bürkert GmbH & Co. KG Fluid Control Systems catalogs and technical brochures

  1. 6012

    14 Pages

  2. 0255

    10 Pages

  3. 0142

    8 Pages

  4. 6724

    13 Pages

  5. Bürkert Select

    452 Pages

  6. DS0117