Intended Use: The Mouse/Rat Triiodothyronine (T3) ELISA kit is designed for research purposes only and is not suitable for diagnostic procedures.
Materials Provided: The kit includes microwells coated with T3 Monoclonal Antibody, T3 standards, T3 enzyme conjugate concentrate, assay diluent, TMB substrate, stop solution, and wash concentrate.
Materials Not Provided: Users need to supply distilled or deionized water, precision pipettes, disposable pipette tips, an ELISA reader, absorbance paper, and graph paper.
Storage and Stability: Store the kit at 2-8°C. Ensure microwells are sealed with desiccants. Reagents are stable until the kit's expiration date. Avoid exposing reagents to heat or strong light.
Warnings and Precautions: The kit is for laboratory use only and contains potential biohazardous materials. Handle reagents at Biosafety Level 2. Do not mix components from different lots and ensure accurate pipetting for optimal results.
Specimen Collection and Handling: Collect blood specimens and separate serum immediately. Store specimens refrigerated for up to 5 days or frozen for up to one month. Avoid multiple freeze-thaw cycles.
Reagent Preparation: Dilute the T3-enzyme conjugate with assay diluent and prepare the wash buffer by diluting the concentrate with water.
Assay Procedure: Bring all reagents to room temperature before use. Format microplate wells, add serum references, and incubate with T3-enzyme conjugate. Wash wells, add TMB substrate, and read absorbance at 450nm.
Calculation of Results: Construct a standard curve by plotting absorbance against T3 standard concentrations. Use the curve to determine the concentration of unknown samples.
Limitations: Sodium azide should not be used as a preservative as it inhibits HRP enzyme activities.
See more

Catalog excerpts

Mouse/Rat Triiodothyronine (T3) ELISA-1

REFERENCES 1. Agharanya JC. Clinical usefulness of ELISA technique in the assessment of thyroid function. West Afr J Med 1990;9(4):258-63. 2. Baumgartner-Parzer sM; Wagner L; Reining G; Sexl V; Nowotny P; Muller M; Brunner M; Waldh'ausl W. Increase by tri-iodothyronine of endothelin-1, fibronectin and von Willebrand factor in cultured endothelial cells. J Endocrinol 1997;154(2):231 -9. 3. Maes M; Mommen K; Hendrickx D; Peeters D; D'Hondt P; Ranjan R; De Meyer F; Scharp'e S Components of biological variation, including seasonality, in blood concentrations of TSH, TT3, FT4, PRL, cortisol and testosterone in healthy volunteers. Clin Endocrinol (Oxf) 1997; 46(5):587-98. 4. Santini F; Chiovato L; Bartalena L; Lapi P; Palla R; Panichi V; Velluzzi F; Grasso L; Chopra IJ; Martino E; Pinchera A Study of serum 3,5,3'-triiodothyronine sulfate concentration in patients with systemic non-thyroidal illness. Eur J Endocrinol 1996;134(1):45-9 CALBIOTECH A life science company Mouse/Rat Triiodothyronine (T3) ELISA Catalog No. T3043T-100 (96 tests) INTENDED USE For Research Use Only. Not for use in diagnostic procedures. Cat#: T3043T-100 (96 tests) For Order and Inquiries, please contact llJ Calbiotech Inc., 1935 Cordell Ct., El Cajon, CA 92020 Tel (619) 660-6162, Fax (619) 660-6970, www.calbiotech.com MATERIALS NOT PROVIDED 1. Distilled or deionized water 3. Disposable pipette tips 4. ELISA reader capable of reading absorbance at 450nm 5. Absorbance paper or paper towel 6. Graph paper STORAGE AND STABILITY 2. Keep microwells sealed in a dry bag with desiccants. 3. The reagents are stable until expiration of the kit. 4. Do not expose test reagents to heat, sun, or strong light. WARNINGS AND PRECAUTIONS 1. For Research Use Only. Not for use in diagnostic procedures. 3. Potential biohazardous materials: The calibrator and controls contain animal and human source components, which have been tested and found non-reactive for hepatitis B surface antigen as well as HIV antibody with FDA licensed reagents. However, there is no test method that can offer complete assurance that HIV, Hepatitis B virus or other infectious agents are absent. These reagents should be handled at the Biosafety Level 2, as recommended in the Centers for Disease Control/National Institutes of Health manual, "Biosafety in Microbiological and Biomedical Laboratories" 1984.

 Open the catalog to page 1
Mouse/Rat Triiodothyronine (T3) ELISA-2

4. Do not pipette by mouth. Do not smoke, eat, or drink in the areas in which specimens or kit reagents are handled. 5. The components in this kit are intended for use as an integral unit. The components of different lots should not be mixed. 6. It is recommended that standards, control and serum samples be run in duplicate. 7. Optimal results will be obtained by strict adherence to this protocol. Accurate and precise pipetting, as well as following the exact time and temperature requirements prescribed are essential. Any deviation from this may yield invalid data. SPECIMEN COLLECTION HANDLING...

 Open the catalog to page 2

All Calbiotech catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.