5100 Multigas Analyser The Rapidox 5100 Multigas Analyser is a high specification portable instrument designed for the analysis, control and monitoring of gas in a wide range of applications including; biogas, syngas, anaerobic digestion and fermentation processes. Up to six gases are simultaneously measured using a range of high precision gas sensors; each sensor is specially designed and calibrated to avoid cross interference effects with background process gas, Safety is ensured by the inclusion of flashback arrestors in the gas measuring circuit where required. Measurable gases include oxygen (O2), carbon monoxide (CO), carbon dioxide (CO2), ozone (O3), moisture (H2O), hydrogen (H2), hydrogen sulphide (H2S), nitric oxide (NO), nitrogen dioxide (NO2), nitrous oxide (N2O), sulphur dioxide (SO2), chlorine (Cl2), methane (CH4) and ethylene (C2H4). When configured for applications where the gases contain energy (e.g. Biogas, Syngas) the calorific value of the gas sample is determined using thermodynamic calculations and simultaneously logged and displayed onscreen. An optional pump enables two modes of operation. For samples that are taken from a gas source at atmospheric pressure or below, the pump is activated to draw a sample through the analyser. Alternatively, the pump can be deactivated when sampling from a source at a greater atmospheric pressure, allowing the gas to flow through the analyser. Gas flow is regulated manually via a rotary knob on the fascia and displayed electronically on the screen. Please contact Cambridge Sensotec for further information or to discuss your requirements. Bespoke sensor combination Lithium battery provides 8 range possesses a number of standard features to enhance functionality. Heavy duty IP66 case Password protection Continuous data logging downloaded via USB mains voltage •
Open the catalog to page 1
Research & Development Gas Recovery Bag Sample Probe Sample Probe Filters Calibration Service Collapsible Sample Probe Specification Ambient Operating Temperature Warm-up Time Measurement Time Battery Life 3-4 minutes at 20oC Approximately 2-4 minutes (dependant on sensor configuration) In excess of 8 hours (up to 500 cycles). 4-6 hour charge Supply Voltage (Charging) Sample Connections Data Output Data Storage 90-260VAC, 50/60Hz 4mm ID/6mm OD Rectus style, closed coupled fittings Excel compatible data via USB memory stick 4GB internal data storage allowing for approximately 1 year of...
Open the catalog to page 2
TLD = Tunable Laser Diode Note: Not all sensor combinations are possible due to interference and cross-sensitivity effects. Please contact Cambridge Sensotec for advice. Sensor Type Rapidox 5100 Sensor Matrix
Open the catalog to page 3All Cambridge Sensotec catalogs and technical brochures
-
Rapidox Gas Recovery
2 Pages