General Specifications
The document describes a modular, compact, directly operated system for proportional control of pressure, flow, and position. It supports 2/2-way and 3/3-way configurations with a maximum flow of 90 Nl/min. The system is compatible with compressed air, inert gases, and oxygen, requiring filtering according to ISO 8573-1 class [7:4:4]. It operates at supply and operating pressures ranging from -1 to 10 bar, with ports sized at G1/8. The materials include FKM seals, and the system can be mounted in any position. It supports analogical inputs of 0-10 V or 4-20 mA and outputs of 0-10 V, with a supply voltage of 24 VDC or 12 VDC. The system interfaces with CANopen CiA 301 and IO-Link, and has a protection class of IP20.
System Components and Configuration
The Open Frame Proportional Controller consists of two base modules: Head and Expansion. It offers closed-loop flow control and is compatible with oxygen. The system can be customized for specific applications, reducing assembly times and complexity. It is suitable for Industry 4.0 applications, with typical uses including gas mixing and pressure piloting in machines.
Technical Data and Performance
The system's performance includes hysteresis of <= 3%FS for pressure control and <= 2%FS for flow control, repeatability of <= 1%FS for pressures less than 1 Bar, and resolution and linearity of <= 2%FS and <= 5%FS respectively. The environmental temperature range is 0 to 60°C, with a weight of 300 g per module.
Coding and Configuration Examples
The document provides coding examples for configuring the system, detailing options for electrical interfaces, control functions, sizes, pneumatic ports, valve sizes, seals material, body material, sensor scales, and pressure settings. It also includes configurations for use with oxygen, adhering to ASTM G93-03 Standard Level E.
Flow and Pressure Control
Flow control is dependent on the combination of differential pressure sensors and calibrated nozzles, with maximum flows ranging from 10 to 90 Nl/min based on specific configurations. The maximum operating pressure is determined by the pilot valve's maximum pressure and the full scale of the relative sensor.
Diagrams and Mounting Instructions
The document includes flow diagrams for closed-loop flow control and pressure regulation, emphasizing the need for accurate calibration according to application specifications. It provides a pneumatic scheme for the head and expansion modules and detailed mounting instructions for assembling the modular components.
Dimensions and Accessories
Dimensions for the Open Frame proportional controller are provided, along with details on available accessories such as mounting brackets, fixing kits, rear brackets, and various cables and connectors for electrical connections.
See more

Catalog excerpts

SERIES OF-1

OPEN FRAME PROPORTIONAL CONTROLLER SERIES OF Closed loop flow control Compatible to be used with oxygen Composed of two base modules: • Customised, turnkey solutions Analog, CANopen or IO-Link interface The Open Frame Controller can be easily configured to meet specific application needs, to provide the most efficient, turnkey solutions, this reducing assembly times and system complexity. The different Head and Expansion modules can be combined and driven through simple serial communications, making the control of complex applications easier. Typical applications could include the mixing of different gases, piloting different pressures in different parts of the machine. The new “Open Frame Controller” system is a platform for providing closed loop control of flow, pressure and position and is suitable for Industry 4.0 applications. The system is composed of two base modules: Head and Expansion. PROPORTIONAL TECHNOLOGY Modular system for proportional control of pressure, flow and position. 8 General Data Construction Modular, compact, directly operated Compressed air, inert gases and oxygen. Filtering according to ISO 8573-1 class [7:4:4] Operating pressure Mounting position Analogical input Analogical output Supply voltage, Current absorbed 24 VDC 0,3A or 12 VDC 0,6A (Head or Expansion Module) BUS interface CANopen CiA 301 IO-Link (connection type portclass B) Protection class Pressure control version <= 3%FS; Flow control version <= 2%FS Pressure control version <= 1%FS for pressures less than 1 Bar <=2%FS; Flow control version <= 2%FS Flow control version <= 2%FS Pressure control version <= 2%FS; Flow control version <= 5%FS Environmental temperature (min 0 ÷ 60°C and max °C) For low temperature on request. Weight Products designed for industrial applications. General terms and conditions for sale are available on www.camozzi.com This document contains a description of the products offered by Camozzi Automation at time of publication. For more complete and up to date information about the Camozzi Automation product range, please refer to our online catalogue at https:/

 Open the catalog to page 1
SERIES OF-2

OPEN FRAME PROPORTIONAL CONTROLLER SERIES OF - CODING EXAMPLES Products designed for industrial applications. General terms and conditions for sale are available on www.camozzi.com This document contains a description of the products offered by Camozzi Automation at time of publication. For more complete and up to date information about the Camozzi Automation product range, please refer to our online catalogue at https://shop.camozzi.com

 Open the catalog to page 2
SERIES OF-3

OPEN FRAME PROPORTIONAL CONTROLLER SERIES OF - TECHNICAL DATA Head valve size 0 Nozzle [mm] Pmax [bar] Full scale of the relative sensor - Only for head B The maximum operating pressure of the device corresponds to the minimum value of the identified pressures. For example: • Valve size "L", 0 1,6 mm, Pmax = 6 bar; • Valve size "H", 0 1,2 mm, Pmax = 8 bar; • Full scale of the relative pressure sensor "E", Pmax 7 bar; • The maximum operating pressure is the lowest of the three; 6 bar. PROPORTIONAL TECHNOLOGY Maximum flow In case of versions with closed loop flow control (control functions Q, C...

 Open the catalog to page 3
SERIES OF-4

OPEN FRAME PROPORTIONAL CONTROLLER SERIES OF - DIAGRAMS PROPORTIONAL TECHNOLOGY Flow diagrams Open Frame - Closed loop flow control valve version Q = Flow ( l/min ) % = Percentage of the command signal A = P out flow = P atmosphere B = Delta flow P 1 bar Q = Flow ( l/min ) % = Percentage of the command signal A = P out flow = P atmosphere B = Delta flow P 1 bar Q = Flow ( l/min ) % = Percentage of the command signal A = P out flow = P atmosphere B = Delta flow P 1 bar Nota 1: The graphs shown above are for reference only. Thanks to the high flexibility of the Open Frame, the different modules...

 Open the catalog to page 4
SERIES OF-5

OPEN FRAME PROPORTIONAL CONTROLLER SERIES OF - DIAGRAMS PROPORTIONAL TECHNOLOGY Flow diagrams Open Frame – 3-way and 2-way Pressure regulator version Note 1: Regarding the pressure regulation graphs shown above, please do not consider the negative values when you refer to the 2-way regulator, as these values relate to the exhaust flow which is absent in the 2-way version. Note 2: The graphs shown above are for reference only. Thanks to the high flexibility of the Open Frame, the different modules will be calibrated accurately according to the specifications of each application, exploiting the...

 Open the catalog to page 5
SERIES OF-6

OPEN FRAME PROPORTIONAL CONTROLLER SERIES OF - DIAGRAMS PROPORTIONAL TECHNOLOGY Pneumatic scheme HEAD MODULE SCHEME EXPANSION MODULE SCHEME P= pressure inlet head A= use of head N= calibrated nozzle 8 Mounting example To correctly mount the modular HEAD and EXPANSION components, insert the fixing elements (A) in the special seats between the two bodies and the O-Ring (C) in the seat on the EXPANSION body. Join the two bodies and fix them into position with the fixing nuts (B), close to the side in contact. The positions of the covers (D), prepared at the factory, cannot be changed. The single...

 Open the catalog to page 6
SERIES OF-7

OPEN FRAME PROPORTIONAL CONTROLLER PROPORTIONAL TECHNOLOGY Products designed for industrial applications. General terms and conditions for sale are available on www.camozzi.com This document contains a description of the products offered by Camozzi Automation at time of publication. For more complete and up to date information about the Camozzi Automation product range, please refer to our online catalogue at https://shop.camozzi.com

 Open the catalog to page 7
SERIES OF-8

OPEN FRAME PROPORTIONAL CONTROLLER SERIES OF - ACCESSORIES Supplied with: 1x mounting bracket 1x screw M4x6 UNI 5931 This accessory cannot be used with the Light sub-base. PROPORTIONAL TECHNOLOGY The single units of the Series Open Frame are supplied already assembled and tested, in case mechanical connection between them is required, use the following kit. Supplied with: 2x shaped steel pins 4x steel grub screws 1x electrical connection Rear bracket OPEN FRAME The kit includes 1x zinc-plated bracket 2x M4x8 white zinc-plated screws USB to Micro USB cable Mod. G11W-G12W-2 For the hardware configuration...

 Open the catalog to page 8

All Camozzi Automation catalogs and technical brochures

  1. SERIES TC

    3  Pages

  2. SERIES CP

    8  Pages

  3. SERIES KL

    6  Pages

  4. SERIES PL

    10  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About MedicalExpo
MedicalExpo is a marketplace that offers B2B players a complete experience, from product sourcing to purchase. MedicalExpo is an entity of VirtualExpo Group.