Stability testing chamber Model No: Q20 Temperature range* • Chart recorder • Additional shelving Chamber features: Standard Temperature control features: • RS485 panel mount-usb cable interface * Simplifies Controller Management with Easy-to-Operate Graphic User Interface * Provides Access to Advanced Scripting Capabilities • Visually interpret thermal data • Control access via software, export data in csv format • 2 programmable alarm ‘Specifications are based on 20°C ambient and standard voltage. Specifications are subject to change without notice. Chamber options: • RO/DI water filtration system • Water carboy Canden stability testing chamber is capable of maintaining stable temperature set points of 25°c , 30°c & 40°c and corresponding relative humidity set points of 60%RH(@25°c), 65%RH(@30°c) and 75% RH(@40°c) with exceptional precision. The chamber has a wide operating temperature range of 18°c t to 40°c maintaining a stable temperature across the entire range. This chamber provides outstanding stability testing performance for manufacturers of pharmaceuticals, biologics, food, and personal care products. Canden stability chambers' performance meets ICH Q1A general case guidelines for pharmaceutical stability testing. Chamber is designed with horizontal airflow for uniform sample exposure. Chamber interior and exterior are made out of stainless steel. Chamber has 2” thick CFC free insulation providing good thermal gradient. Door locks are standard in doors. Chambers comes with 2” access port with insulation plug. Chamber also includes pre-installed casters capable of supporting 150-200lbs per caster. Chamber uses thermoelectric assembly for heating and cooling. This type of cooling/heating system completely eliminates need for conventional refrigeration system and failures due to mechanical components such as compressors thereby drastically increasing the life expectancy of each chamber. Maintenance cost is also lowered by the thermoelectric/Peltier driven heating/cooling system. The chamber is quiet in operation. Back wall plenum on chambers ensures uniform distribution of conditioned air. Chamber temperature setpoints are tightly controlled using PID controller. Standard Humidity control features: • 3% accuracy over the entire input range-displays PV/SV. • On/off controller is standard. if you need PID controller with tighter control up to 1% RH- please contact us. • Dual alarm outputs with 10+ activation methods/situation • High brightness, large LED display Canden Products St. Louis, Mo Email: sales@.
Open the catalog to page 1Stability testing chamber Model No: Q20 Humidity system: Humidity control is optional. Humidity range is achieved via additive ultrasonic humidification, a controller with with factory calibrated %RH sensor. Humidifier is installed typically in the rear of the chamber and can be easily serviced or replaced. RO/DI system is recommended but not required as long as the water quality specification is met. Tap water should be fine. The humidifier comes with a 15' %” polytube, shut off valve and quick disconnect fittings as well as a fitting to connect to water faucet. Water quality...
Open the catalog to page 2