Product Overview: SafetyTector® S (article no. 400) is a SARS-CoV-2-inactivating dilution and extraction buffer designed for immunoassays using saliva or mucosal swab samples. It is intended for general laboratory use and is not a chemical disinfectant, antiseptic, or preservative.
Storage and Composition: The product should be stored at 2 - 8 °C. It has a pH value of 7.2 ± 0.2 at 19.0 – 21.0 °C and contains less than 0.0014% [w/w] of CMIT/MIT (3:1) as a preservative.
Applications: SafetyTector® S is used as a diluent for immunoassays, including lateral flow assays and ELISA. It inactivates SARS-CoV-2 in saliva or mucosal swab samples at a 1:4 dilution within 1 minute, as confirmed by the Institute of Molecular Virology, University Hospital Ulm.
Instructions for Use: The buffer is ready-to-use and should be shaken thoroughly before use. Samples must be diluted at least 1:4 with SafetyTector® S. For lateral flow assays, it replaces various buffers and requires saliva to be diluted with at least three volumes of SafetyTector® S. Swabs should be incubated and squeezed in the buffer for optimal recovery.
Compatibility: SafetyTector® S can be used with other assay technologies like ELISA, protein arrays, and automated high-throughput systems. Users must test its suitability for specific assays.
Effectiveness: Treatment with SafetyTector® S reduces the mean SARS-CoV-2 infection dose significantly within 1 to 5 minutes. However, its effectiveness may vary with different sample matrices and higher virus concentrations.
Trademark: SafetyTector is a registered trademark of CANDOR Bioscience GmbH.
See more

Catalog excerpts

SafetyTector® S-1

SARS-CoV-2-inactivating1 dilution and extraction buffer for immunoassays based on saliva or mucosal swab samples Storage: contains < 0.0014 % [w/w] reaction mass of CMIT/MIT (3:1) Expiry date when stored unopened: see label on the bottle For general laboratory use SafetyTector® S is not a chemical disinfectant, antiseptic, or preservative Fields of application SafetyTector® S is a ready-to-use diluent for immunoassays based on saliva or mucosal swab samples. Diluted samples are directly applied to lateral flow assays as flow buffer. Swabs can be extracted directly with SafetyTector® S. Diluted samples can also be used in other immunoassays such as ELISA. SafetyTector® S inactivates SARS-CoV-2 and improves the texture of potentially infectious saliva or mucosal swab samples. At a 1:4 dilution, SafetyTector® S is able to inactivate SARS-CoV-2 in these samples within 1 min1 (For details please refer to the „ Letter of Acknowledgement“issued by the Institute of Molecular Virology, University Hospital Ulm). Instructions for use SafetyTector® S is ready-to-use. Please shake the buffer thoroughly before use. Dilution of the specimens: Samples must be diluted in SafetyTector® S at least 1:4 (1 part sample in 3 parts SafetyTector® S) and mixed thoroughly. Standards and specimens should be treated strictly the same way. SafetyTector® S is not suited for long-term storage of specimens. Lateral flow assays: SafetyTector® S replaces the dilution buffer, extraction buffer, chase buffer or flow buffer. Saliva must be diluted with at least 3 sample volumes of SafetyTector® S. Swabs must be incubated in SafetyTector® S and should be squeezed for optimal sample recovery, if applicable. Volume of SafetyTector® S must at least be 3 times the maximum capacity of the swab. Other assay technologies: SafetyTector® S may also be employed as sample diluent if saliva or mucosal swab samples are analysed by technologies like ELISA, protein arrays, bead assays (e.g. Luminex assays), immuno-PCR, or automated high-throughput immunoassay systems. Suitability of SafetyTector® S for a specific assay has to be tested by the user. For further information please visit www.candor-bioscience.com. SafetyTector is a registered trademark of CANDOR Bioscience GmbH. 1: Treatment with SafetyTector® S reduced mean SARS-CoV-2 infection dose by 3.5 log10 after 1 min and by 4.0 log10 TCID50/ml after 5 minutes of incubation. No remaining infectivity could be detected with the used method. This test was performed using infectious virus isolates diluted in human saliva. The effectiveness of this treatment against SARS-CoV-2 may vary when used to inactivate other sample matrices. Demonstrating complete inactivation is dependent on the concentration of virus in the sample. SARS-CoV-2 in samples that show a higher level of infectious virus than those examined in this study may not be inactivated completely and could potentially remai

 Open the catalog to page 1

All CANDOR Bioscience catalogs and technical brochures

  1. BSA-Block

    1  Page

  2. SmartBlock™

    2  Pages

  3. ReadyTector

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.