Product catalog summary
Product Overview:
Washing Buffer 10x is designed for use in immunoassays. The available products include Washing Buffer PBS 10x, PBS 10x without Tween, TRIS 10x, and TRIS 10x without Tween. Each product has a specific article number for identification.
Storage Instructions:
The buffer should be stored at temperatures between 2 – 8 °C or -15 to -30 °C. It can withstand repeated freezing and thawing cycles.
pH Specifications:
The pH value at 19.0 – 21.0 °C is 7.2 ± 0.2 for articles 140, 145, and 146, and 7.3 ± 0.2 for article 141, when diluted 1:10.
Preservative Information:
The buffer contains less than 0.0014% [w/w] of a reaction mass of CMIT/MIT (3:1) as a preservative.
Expiry and Usage:
The expiry date is indicated on the bottle label. The working solution should be used immediately after preparation.
Instructions for Use:
Before preparing the working solution, warm the buffer to room temperature to dissolve any precipitated salt crystals. Mix thoroughly by shaking. Dilute the stock solution 1:10 with distilled or demineralized water and use on the same day.
Compatibility and Testing:
The buffer can be used in automated washers, subject to the washer's salt tolerance. Users must test the buffer's suitability for specific assays.
Additional Information:
For more details, visit the website www.candor-bioscience.com.
See more

Catalog excerpts

Washing Buffer 10x-1

Washing Buffer 10x Wash Buffer for immunoassays Available products: Washing Buffer PBS 10x Washing Buffer PBS 10x without Tween Washing Buffer TRIS 10x Washing Buffer TRIS 10x without Tween (article no. 140) (article no. 141) (article no. 145) (article no. 146) 2 – 8 °C or -15 to -30 °C (tolerates repeated freezing and thawing cycles) contains < 0.0014 % [w/w] reaction mass of CMIT/MIT (3:1) Expiry date when stored unopened: see label on the bottle Use working solution immediately! For general laboratory use Instructions for use Salt crystals may precipitate due to storage at 2 - 8 °C or freezing. Therefore, to prepare the working solution, the Washing Buffer must be warmed to room temperature beforehand, which will dissolve any salts that may have precipitated. The buffer should be thoroughly mixed again by shaking immediately before use. The working solution is prepared from the stock solution by diluting 1:10 with distilled or demineralized water and should be used on the same day. Washing Buffer can be used in automated washers depending on the salt tolerance of the washer. It is essential to observe the specifications of the respective manufacturer! Suitability of Washing Buffer for a specific assay has to be tested by the user. For further information please visit www.candor-bioscience.com.

 Open the catalog to page 1

All CANDOR Bioscience catalogs and technical brochures

  1. BSA-Block

    1  Page

  2. SmartBlock™

    2  Pages

  3. ReadyTector

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.