1. Catalogs
  2. Canon Medical System U.S.A
  3. CXDI-50RF Specifications
video corpo

CXDI-50RF Specifications

CXDI-50RF Specifications

Product catalog summary
Product Specifications Summary
Static Detector
  • Method: Utilizes a Flat Panel Detector with Scintillator and Amorphous Silicon (a-Si) in an RF System.
  • Cassette: Features a CsI (TI) Scintillator and LANMIT Sensor with a pixel pitch of 160 microns, totaling approximately 5.9 megapixels.
  • Imaging Area: Automatically sizes up to 14 x 17 inches (35 x 43 cm).
  • Components: Includes a Sensor Unit and Power Supply.
Dynamic Detector
  • Binning Mode: Supports 1 x 1 and 2 x 2 modes.
  • Acquisition Mode: Capable of up to 30 frames per second.
  • Cooling: Features active air cooling.
Image Acquisition and Processing
  • Image Processing: Utilizes MLT(S) for static images and recursive and multi-frequency filters for dynamic images.
  • A/D Conversion: 14-bit conversion with 4,096 grayscale levels (12-bit).
  • Preview and Full Image Display: Preview available approximately 2-4 seconds after X-ray exposure, with full image display in approximately 4 seconds.
Data Output and Network Connection
  • Network: Ethernet 10/100/1000 Base T, RJ45 standard, with optional wireless connectivity.
  • DICOM Compatibility: DICOM 3.0 compatible, supporting Print Management and Storage Service Classes (SCU).
Electrical and Environmental
  • Voltage: Operates on AC 100-240V, 50/60Hz.
  • Operating Environment: Sensor Unit operates between 41-95°F (5-35°C) with 30-75% relative humidity (non-condensing).
Physical Characteristics
  • Dimensions: 19.4 x 19.8 x 1.0 inches (493 x 503 x 26 mm) for the detector unit only.
  • Weight: 12.5 lbs (5.7 kg).
Note: Specifications are subject to change without notice.
See more

Catalog excerpts

CXDI-50RF Specifications-1

Product Specifications Static Detector Method Scintillator Sensor Pixel Pitch Pixels Imaging Area Standard Components Dynamic Detector Binning Mode Acquisition Mode Cooling Flat Panel Detector, Scintillator & Amorphous Silicon (a-Si), RF System Cassette Csl (CsI: TI) LANMIT (Large Area New-MIS Sensor and TFT) 160 Microns 2,208 x 2,688 Pixels (Approximately 5.9 Megapixels) Automatic Sizing Up to 14 x 17 in (35 x 43 cm) Sensor Unit, Power Supply Image Acquisition and Processing Image Processing MLT(S) (Static) Recursive Filters and Multi-Frequency Filters (Dynamic) A/D 14-bit Grayscale 4,096 Grayscale (12-bit) Preview Image Approximately 2-4 Seconds After X-ray Exposure (Radiography Only) Full Image Display Approximately 4 Seconds After X-Ray Exposure (Radiography Only) Data Output and Network Connection Network Ethernet 10/100/1000 Base T, RJ45 Standard, Wireless Optional DICOM DICOM 3.0 Compatible, Print Management Service Class (SCU), Storage Service Class (SCU) Electrical and Environmental Voltage AC 100-240V 50/60Hz Operating Sensor Unit: 41-95 F (5-35 ºC), Humidity 30-75% RH (non-condensing) Environment Physical Characteristics Dimensions (W x L x 19.4 x 19.8 x 1.0 in (493 x 503 x 26 mm) H) (Detector unit only) Weight 12.5 lbs (5.7 kg) Specifications are subject to change without notice. © 2015 Canon U.S.A., Inc. All Rights Reserved. Reproduction in whole or part without permission is prohibited.

 Open the catalog to page 1

All Canon Medical System U.S.A catalogs and technical brochures

  1. CX-1

    13  Pages

Archived catalogs

  1. CXDI-80C

    2  Pages

  2. CXDI-501C

    2  Pages

  3. CXDI-501G

    2  Pages

  4. CXDI-401

    2  Pages

  5. CXDI-55C

    2  Pages

  6. CXDI-55G

    2  Pages

  7. CXDI-60C

    2  Pages

  8. CF-1

    2  Pages

  9. CXDI-60G

    4  Pages

  10. CR-2

    2  Pages

  11. CR-2 PLUS

    2  Pages

  12. TX-20

    2  Pages

  13. RK-F2

    2  Pages

  14. PTS 1000

    2  Pages

  15. flyer RICS

    2  Pages

  16. CXDI-401C

    1  Page

  17. CXDI-701C

    1  Page

  18. CXDI-801C

    1  Page

  19. RadPRO® URS

    2  Pages

  20. Vantage Elan

    19  Pages

  21. Vantage Titan

    17  Pages

  22. Aplio a450

    16  Pages

  23. Aplio a550

    20  Pages

  24. CR-2 AF

    8  Pages

  25. OMNERA® 400A

    2  Pages

  26. CR-2 PLUS AF

    8  Pages

  27. RK-F2