Catalog excerpts

PTS 1000 Technical Data 300 mm radius, closed type, ventilated Tested field range 100 ° (160 with fixation shift horizontally) Perimetry technique Static, kinetic Stimulus size Goldmann Sizes I-V Stimulus colors Automated Perimeter PTS 1000 Examination bowl white, blue, red, green Stimulus speed in kinetic perimetry 2-10°/s Maximum Stimulus intensity 10000 asb Fixation method control of blind spot position or digital detection of pupil position Patient response time adaptive to patient speed or set manually from 0,1 to 9,9s Background illumination depends on stimuli type-31,5 asb for white and red stimuli, 10 asb for green, 314 asb yellow background for blue stimuli, set automatically Maps 24 (24° with extent to 30°nasally), 30 (central 30°), Full (50° in every directions) Central (30° in horizontal axis and 22° in vertical axis) Glaucoma (30° with extent up to 50° in nasal direction) Peripheral (from 30° to 50°), Macula (up to 10°) Extended (special field for drivers examination – 50° in nasal direction; 80° in temporal direction), Fast (up to 30° with scarce points) Binocular Drivers Test (up to 80° in horizontal axis, up to 50° in vertical axis) User (up to 50° user defined) Strategies Kinetic, Screening, Threshold, 3-zone, Fast threshold, BSV (Binocular Single Vision), Flicker (Critical Fusion Frequency), Blue On Yellow (SWAP) BDT (Binocular Drivers Test), Advanced – Reduced field option – Neurological defects option Result maps age norm deviation (total deviation), pattern deviation, hill of vision deviation defect probability graph,defects progress analysis, ,results overview Bebie curve, Pupil movement graph, 3D visualization of patients HOV. OPTOPOL Technology S.A. Interface USB Tel/Fax: +48 32 6709173 info@optopol.com.pl Dimensions 693 x 585 x 444 HxWxD Operating Voltage 100-250V 50-60Hz Additional features Eye monitoring by means of built-in video camera. Advanced auto-detection of eye position. Automatic pupil diameter measurement. Automatically controlled chin-rest enables to set proper patient’s position precisely and easily Printout manager with predefined printout styles. Network capabilities (remote database, networked review stations). Direct database back-up. Special ventilation system is used to keep fresh air throughout examination inside stimulation bowl ul. Żabia 42, 42-400 Zawiercie, POLAND www.optopol.com Local Distributor: ver. PTS1000 03-2009 PTS 1000
Open the catalog to page 1
Automated Perimeter PTS 1000 is a modern diagnostic instrument for precise and fast testing of field of vision. It offers static and kinetic stimuli with all Goldmann stimuli sizes and all stimuli colors used in perimetry. Wide range of strategies and analysis tools combined with intuitive interface give you powerful diagnostic tool whose handling you will enjoy. Built-in maps and possibility of creating own ones give a chance to examine only these areas, which are necessary. With PTS1000 examination doesn't have to be tiring anymore. FLICKERING TEST ANALYSIS TOOLS Depending on chosen test...
Open the catalog to page 2All Canon Medical System U.S.A catalogs and technical brochures
-
CX-1
13 Pages
-
Aquilion ONE / PRISM Edition
26 Pages
-
Aplio a550
16 Pages
-
CR-2 AF/ CR-2 Plus AF
13 Pages
Archived catalogs
-
RK-F2
4 Pages
-
CR-2 PLUS AF
8 Pages
-
OMNERA® 400A
2 Pages
-
CXDI-50RF Specifications
1 Pages
-
CR-2 AF
8 Pages
-
Aplio a550
20 Pages
-
Aplio a450
16 Pages
-
Vantage Titan
17 Pages
-
Vantage Elan
19 Pages
-
Vantage Galan 3T
40 Pages
-
RadPRO® URS
2 Pages
-
RadPRO® OMNERA® 400T
2 Pages
-
CXDI-801C
1 Pages
-
CXDI-701C
1 Pages
-
CXDI-401C
1 Pages
-
flyer RICS
2 Pages
-
image SPECTRUM Brochure
8 Pages
-
CR2 Plus AF Brochure
8 Pages
-
RK-F2
2 Pages
-
TX-20
2 Pages
-
CR-2 PLUS
2 Pages
-
CR-2
2 Pages
-
CF-1
2 Pages
-
CX-1
4 Pages
-
CXDI-60G
4 Pages
-
CXDI-60C
2 Pages
-
CXDI-55G
2 Pages
-
CXDI-55C
2 Pages
-
CXDI-401 COMPACT
2 Pages
-
CXDI-401
2 Pages
-
CXDI-501G
2 Pages
-
CXDI-501C
2 Pages
-
CXDI-80C
2 Pages
-
CXDI-70C Wireless
8 Pages