URO-GYNECOLOGICAL TECARTHERAPY
2Pages

{{requestButtons}}

Catalog excerpts

URO-GYNECOLOGICAL TECARTHERAPY - 1

1rst Generation Tecar Classic Probe | Without sensor Classic Probe vs MJS Differences between intracavitary accessories - Only one size - Only internal use - Reduced energy delivery due to lack of control of the temperature increase in the tissues - No temperature sensor - One-way communication - One temperature level - Bio-stimulation - Single patient – with consumables Capenergy offers two intracavitary accessories: the classic probe and the MJS probe. The difference between these two technologies is quite clear. While the classic probe is merely an inert element that’s introduced in an electrode holder, the MJS probe has an engineering design, developed specifically for its successful application to the pelvic floor. They also have a different technological evolution based on their therapeutic target: while the first one only allows for athermal bio-stimulation, the second one has the ability to generate collagen thanks to its controlled hyper-thermal effect. The intracavitary probe obtains scientifically proven results in 6 months’ time (1 session per week, 24 sessions). 2nd Generation TecarEvolution MJS probe | With sensor - Biofeedback with the device - Intracavitary and extracavitary use - Double temperature control - Intracavitary probes of different shapes and sizes for specific indications. - Anatomically shaped - Multipatient (use of probe covers) - Without expensive accessories - Biostimulation + generation of collagen Average reduction on the VAS scale after 30 days of treatment and after 3 months 8,00 The intracavitary MJS probe obtains proven results within a month. (5 sessions, 1 per week)1 Evolution of pain for treatments with the intracavitary MJS probe. Sample of patients participating in the study: 11 | Conclusion: pain disappears after a month. Pinheiro C, Costa T, Amorim de Jesus R, Campos R, Brim R, Teles A, Vilas Boas A, Lordêlo P. Intravaginal nonablative radiofrequency in the treatment of genitourinary syndrome of menopause symptoms: a single-arm pilot study. BMC Womens Health. 2021 Oct 30;21(1):379. doi: 10.1186/s12905-021-01518-8. Tecar Therapy Urogynecology European regulation: Medical Device. Notified Body CE 0120. Directive 93/42/EEC. EN 60601-1:2008. Medical electrical equipment - Part 1: General requirements for basic safety and essential performance. EN 60601-1-2:2008 - Medical electrical equipment - Part 1-2: General requirements for basic and essential performance - Collateral standard: electromagnetic compatibility - Requirements and tests.

Open the catalog to page 1
URO-GYNECOLOGICAL TECARTHERAPY - 2

TecarSpecialty C500 Urogyne Capacitive Electrical Transference device for a quality intracavitary urogynecological physiotherapy treatment. • Mode: Intra • Power: 310W • 1 channel • 3 frequencies • Weight: 13 Kg • Dimensions: 345x420 mm x 220 mm • Intracavitary MJS probe TecarSpecialty C25 Urogyne • Mode: Intra • Power: 200W • 1 channel • 4 frequencies • Weight: 3,5 Kg • Dimensions: 170x220 mm x 250 mm • Intracavitary single patient probe 1rst Generation Tecar TecarSpecialty C25 Physio Urogyne • Mode: Cap | Res • Power: 200W • 1 channel • 4 frequencies • Weight: 3,5 Kg • Dimensions: 170x220...

Open the catalog to page 2

All Capenergy Medical catalogs and technical brochures

  1. DRAKARIAN EN

    2 Pages

  2. UROLOGIC

    2 Pages

  3. GYNECOLOGIC

    2 Pages