Overview: The CapIMAGE™ SFOV Gamma Camera is a versatile imaging system designed for small field of view applications, ideal for imaging small organs such as the thyroid and parathyroid, as well as for pediatric imaging. It enhances productivity by freeing up larger gamma cameras for more complex procedures.
System Features:
  • Movable Gantry: Equipped with free-rolling wheels and a handheld collimator with clear angle markings for precise positioning.
  • Laptop Base Rotation: Features a 180-degree swivel base for optimal patient setup and monitoring.
  • Buttons Interface: Includes quick-release solenoid locks for rapid manual tilt/rotation and a rapid collimator exchange system.
  • Highly Adaptable Head: Accommodates both upright and supine patient imaging with an 8.25-inch circular field of view.
Applications: CapIMAGE supports diverse planar applications including imaging of the right hand, shoulder, left knee, and thoracic spine. It offers high-quality spatial and energy resolution with user-defined processing and acquisition protocols.
Technical Specifications:
  • Acquisition and Processing: Utilizes a laptop with a minimum 1200 MHz Pentium III processor and Windows Vista, supporting various image manipulation and display functions.
  • Camera QC: Features software for uniformity correction, automated calibration, and NEMA-compliant testing.
  • Environmental Specifications: Operates within 15-30°C and 20%-80% RH, with a voltage requirement of 90-264 VAC.
Optional Components: Includes various collimators and a MUGA option for expanded functionality.
Conclusion: The CapIMAGE™ SFOV Gamma Camera is designed for multiple clinical environments, offering flexibility and efficiency in small organ imaging.
See more

Catalog excerpts

CapIMAGE ™ Small Field-of-View Gamma Camera Brochure-1

SFOV Gamma Camera Small Field, Big View

 Open the catalog to page 1
CapIMAGE ™ Small Field-of-View Gamma Camera Brochure-2

CapIMAGE™ S F O V G amma came r a CapIMAGE™ provides versatility for multiple patient positions to accommodate planar, gated and dynamic images CapIMAGE is a small field of view gamma camera system ideal for imaging small organs and body parts including the thyroid, parathyroid, planar bone images, and gated cardiac studies. Additionally, CapIMAGE provides a convenient platform for pediatric imaging. CapIMAGE can improve instrumentation and staff productivity by providing an alternative for imaging small organs; thus, freeing up the large field of view gamma cameras for the more complex procedures...

 Open the catalog to page 2
CapIMAGE ™ Small Field-of-View Gamma Camera Brochure-3

if diversity and quality are key to YOUR practice RAO Pinhole Thyroid CapIMAGE Offers: • Unique detector stability • High quality spatial and energy resolution • Algorhythms optimized for photon position User-Defined Processing Protocols: • Image filtration • Flexible display formats ANT Thyroid (LEHR Collimator) User Defined Acquisition Protocols: • User defined static, dynamic and gated acquisition protocols • Thyroid uptakes and imaging • Parathyroid imaging • Gated cardiac imaging • Planar skeletal imaging DICOM Interface: • Rapid data communication with HIS/RIS and PACS systems • Worklist...

 Open the catalog to page 3
CapIMAGE ™ Small Field-of-View Gamma Camera Brochure-4

CapIMAGE™ S F O V G amma came r a Acquisition and Processing Hardware: Laptop- Min. 1200 MHz Pentium III Windows Vista Minimum screen resolution 1400x1050 Acquisition functionality: General: Processing: On board user processing for image manipulation and display Persistence scope: 256x256 matrix plus energy spectrum Pixel size: 4 mm square (64 matrix) or 0.5mm (512 matrix) Zoom factors: 1-5 user selectable in 0.1 increments Image orientation: 0, 90, 180 and 270 degrees User definable acquisition protocols: re-defined acquisitions with all parameters set: P Select acquisition, position camera...

 Open the catalog to page 4
CapIMAGE ™ Small Field-of-View Gamma Camera Brochure-5

Uniformity correction Detector peaking: Uniformity check: Resolution check: Camera QC: NEMA: Isotope and collimator specific; Intrinsic or extrinsic calibration Automated calibration procedure Isotope and collimator specific Intrinsic or extrinsic flood check “Low count” for visual checks “High count” for automatic NEMA analysis and reporting Reporting comprises measured energy peak, uniformity results and energy resolution 4 field bar phantom image visual inspection QC settings preset with software Compliant software for testing built in

 Open the catalog to page 5
CapIMAGE ™ Small Field-of-View Gamma Camera Brochure-6

SFOV GAMMA CAMERA System Specifications Specifications CFOV UFOV Intrinsic Spatial Resolution Intrinsic Energy Resolution Intrinsic Flood Field Uniformity Intrinisic Spatial Linearity Intrinsic High County Rate Performance Maximum Count Rate 250kps Intrinsic Flood Field Uniformity at 75 kcps Multiple Window Spatial Resolution <2mm System Sensitivity LEGP Collimator 270 cpm/|aCi Environmental Specifications Optional Accessories Diverging Collimator LEGP Collimator LEPH Collimator LEDV Collimator MUGA Option LEHR Collimator System type: Acquisition types: Approx. Dimensions Detector Reach Detector...

 Open the catalog to page 6
CapIMAGE ™ Small Field-of-View Gamma Camera Brochure-7

CREATED FOR USE IN MULTIPLE CLINICAL ENVIRONMENTS AND FOR VARIOUS IMAGING APPLICATIONS

 Open the catalog to page 7
CapIMAGE ™ Small Field-of-View Gamma Camera Brochure-8

OPTIONAL COMPONENTS LEDV Collimator: Item #5820-2001 MUGA Option: Item #5830-2002 Gated Trigger Monitor: Item #5830-2002 6 Arrow Road, Ramsey, NJ 07446 • 201.825.9500 or 800.631.3826 • www.capintec.com , Capintec and CapIMAGE are registered trademarks of Capintec, Inc.

 Open the catalog to page 8
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.