KL-SR - 1

Kirby Lester KL-SR Kirby Lester KL-SR The Right Amount Of Automation Function: Automatically verifies, labels, counts, and presents completed prescriptions for tablets/capsules. Highly Efficient Rx Filling General Specifications Dimensions: 29.75”W x 67.5”D x 78.25”H; Approx. 1,400 lbs. installed. Cassettes: 108 universal cassettes, 6½W”x 8”D x 4 3/8”H, capacity 650cc, calibrated on device. Approx. maximum capacity 1,200 ibuprofen 200mg (round/ brown). Automation by Capsa Healthcare • No “slow movers” that expire before dispensing. • Maintain a higher level of control over shrinkage and diversion. • Tighter inventory management. • Less than 6’ deep. Prescription Archive: Retrieve any past dispensed prescription onscreen and via printable report, up to 10 years. Capsule Dimensions: Length minimum 5 mm, maximum 26 mm; Width minimum 5 mm, maximum 15 mm. Tablet Dimensions: Diameter/width minimum 5 mm, maximum 15 mm; Height minimum 2 mm, maximum 10mm. 1. Cassettes can only be removed by an authorized user. Ideal for scheduled and high-value medications, and inventory control. 2. Open the KL-SR Camera Chamber and insert the new pill. Digital image processing technology calculates detailed measurements of the new pill. The dimensions will be saved. 3. With any cassette being recalibrated in the Cassette Station, the KL-SR automatically adjusts the cassette for that pill size; the cassette stays calibrated, no future adjustment is needed. Change medications at any time – no need to order additional cassettes. 4. Cassettes can only be opened for replenishment or return-to-stock while docked in the Cassette Station and by an authorized user. FillSafe™ prevents accidental mis-fills and unauthorized access. Reports: Offers over 20 standard reports that are customizable for your pharmacy's needs. Cassette Replenishment: FillSafe™ Security System prevents unauthorized filling, depleting or switching medications in any cassette; customizable for each pharmacy’s workflow and security needs. Revolutionary Cassette Technology The KL-SR uses technology to calibrate cassettes instead of human adjustment. The medication database contains precise measurements for common NDCs, and your cassette will auto-calibrate. However, on occasion you will want to automate a new tablet or capsule that is not yet in the database (e.g., new generic). The KL-SR handles measurement and storage of the new pill dimensions. Pharmacy Management System Interface: Available for most common platforms. Throughput: Up to 120 labeled, counted and presented prescriptions per hour; 9 vial pick-up windows. • 50% (or more) of total daily prescriptions handled by the KL-SR from 108 cassettes. Printer: Fast-feed, direct thermal labels, 4” x 2”. 1,200 labels per roll, flexible design customizable for each pharmacy, 2” core on supply and pick-up (6” label available). Touch Screen: 15” color LCD. Operating System: MS Windows 10 IoT. Power: Requires a dedicated standard 115V, 60Hz, 15A power outlet. Normal operation draws up to 300w/hr, not to exceed 500w. Vial Size: Small (either 13, 16 or 20 dram), and large (40 dram). Available with both vial bins set for 40 dram. Vial Replenishment: Fast random load, no handloading needed. Vial Types: Accommodates 6 vial styles • Berry (Kerr) Friendly & Safe 13, 16 or 20 dram; and 40 dram • Berry (Kerr) Perfect Pak 12, 16 or 20 dram; and 40 dram • Centor (Rexam) 1-Clic 13, 16 or 20 dram; and 40 dram • Centor (Rexam) Screw-Loc 13, 16 or 20 dram; and 40 dram • Altium (Tri State) Pro One 13 or 16 dram; and 40 dram • Altium (Tri State) Pro Tect 13, 16 or 20 dram; and 40 dram Maintenance: Once-a-day cleaning recommended (approximately 1 minute) ISO 27001:2013 certified for data encryption and HIPAA compliance. Kirby Lester automation Count + Verify 100% Of Orders While the KL-SR robot manages the most common medications, a Kirby Lester tabletop KL1 or KL1Plus is used to fill the balance of prescriptions. No prescriptions are left to chance or human error. KL1 (left) simple, fast and accurate tablet counter. KL1Plus (right) scan-verify & count, plus C-II log and inventory management software. Prevent wrong medication, strength, or quantity, and keep a record of all transactions. Automation by Capsa Healthcare Kirby Lester is pharmacy automation by Capsa Healthcare, a comprehensive solutions leader in medication management, healthcare IT and pharmacy technology. Capsa’s diverse products are deployed globally in all types of pharmacy: retail, long-term care, hospital inpatient and outpatient, central fill and mail order. Automation by Capsa Healthcare Kirby Lester KL-SR Secure Robot

Open the catalog to page 1
KL-SR - 2

Kirby Lester KL-SR Kirby Lester KL-SR Secure Robotic Dispenser Protection plus flexibility. That’s precisely what our engineers built into the Kirby Lester KL-SR Secure Robotic Dispenser. The KL-SR offers breakthrough robotic innovations. The system efficiently automates your pharmacy’s most common tablets and capsules via newly designed universal cassettes that require no technician calibration. Thus, there is virtually no chance for human error when changing the medication in the cassette. The KL-SR brings peace of mind on many levels: Freedom from error, from tedious recalibration, from...

Open the catalog to page 2
KL-SR - 3

Kirby Lester KL-SR Kirby Lester KL-SR The Right Amount Of Automation Function: Automatically verifies, labels, counts, and presents completed prescriptions for tablets/capsules. Highly Efficient Rx Filling General Specifications Dimensions: 29.75”W x 67.5”D x 78.25”H; Approx. 1,400 lbs. installed. Cassettes: 108 universal cassettes, 6½W”x 8”D x 4 3/8”H, capacity 650cc, calibrated on device. Approx. maximum capacity 1,200 ibuprofen 200mg (round/ brown). Automation by Capsa Healthcare • No “slow movers” that expire before dispensing. • Maintain a higher level of control over shrinkage and...

Open the catalog to page 3

All Capsa Healthcare catalogs and technical brochures

  1. Trio

    11 Pages

  2. C-Series

    1 Pages

  3. M38e

    2 Pages

  4. Point-of-Care

    28 Pages

  5. Wire Carts

    11 Pages

  6. LTC versa

    2 Pages