1. Catalogs
  2. Cardia International
  3. CardiAid Technical Spec Brochure - EN

CardiAid Technical Spec Brochure - EN
1 /2Pages

CardiAid Technical Spec Brochure - EN

CardiAid Technical Spec Brochure - EN
1 /2Pages

Catalog excerpts

CardiAid Technical Spec Brochure - EN-1

THE NEW GENERATION CARDIAID CardiAid introduces two new AEDs: Semi-automatic CardiAid CT0207RS and fully automatic CardiAid CT0207RF; improved with superior functions and impressive details. One more step towards perfection… CardiAid CT0207RF Fully-automatic: No need to press the button to deliver the shock. CardiAid CT0207RS One-button operation to provide easier control for the rescuer. Paediatric treatment possible using paediatric electrodes. More than 20 language options. Auto-recognition of paediatric mode when special electrodes are plugged in. Easily adaptable to future changes in resuscitation guidelines with configurable functions like voice prompts, CPR duration, CPR sequence (30:2 or compressions-only); and chest compression frequency (100 to 120 bpm). Accurate ECG detection algorithm with high sensitivity and specificity. Current-based defibrillation technology for the most effective treatment. Improved illustrations and verbal instructions. Recording multi-events up to 3 hours. Cardia International A/S Hersegade 20 · 4000 Roskilde · Denmark Phone: +45 7033 5353 · Fax: +45 3211 3253 www.cardiaid.com · [email protected] Ready-to-communicate with a Gateway and able to send real-time self test results. New generation CardiAid Monitor 2 Technical Service Software offering a whole solution for all needs: Configuration, maintenance, troubleshooting, event data monitoring and many

 Open the catalog to page 1
CardiAid Technical Spec Brochure - EN-2

TECHNICAL SPECIFICATIONS Defibrillation System Defibrillation Electrodes Operating Mode: Automated (CT0207RS: one button operation /CT0207RF: full-automatic). Range of Application: Adult electrodes for patients >8 years / 25kg. Paediatric electrodes for patients 1-8 years / <25kg. i) Temperature: +5˚C to +55˚C ii) Temperature: -20˚C to +70˚C (max 2 weeks, without battery & electrodes) ii) Humidity: 0-95% iii) Air Pressure: 500-1060h/PA Energy Delivery: Adjusted to patient impedance, Programmable (factory settings). Delivered Energy - Adult Mode: 170J (Average for 50 Ω at low energy level). 270J...

 Open the catalog to page 2

All Cardia International catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.