video corpo

touchECG System conf. Package Windows HD+
5Pages

{{requestButtons}}

Catalog excerpts

touchECG System conf. Package Windows HD+ - 1

touchECG General Information Product name Generic name touchECG - Windows Product code Cardioline Spa Head Office and Production: Via Linz, 151 38121 Trento Italy touchECG is a software implementing a 12 channels diagnostic electrocardiograph which displays, acquires, prints and stores ECG traces for adults and children. It also calculates the principal global ECG parameters. The device can be supplied with the optional 12-lead Glasgow resting ECG interpretation algorithm, with specific criteria for patients of different age, sex and race. If this option is enabled, the algorithm can provide the physician of reference with an automatic interpretation, generating diagnostic messages in the ECG report. For further information on the resting ECG interpretation algorithm, see the Instruction Manual for doctors for its use with adults and children (see list of accessory equipment). The device can be configured with the DICOM® function. The device can be installed on any PC, tablet or notebook that complies with the minimum requisites listed. Supported print formats include: Standard or Cabrera 3x4, 3x4+1 rhythm leads (10s), 3x4+3 rhythm leads, 6x12 or 12 channels in automatic mode and 3, 6 or 12 continuous printout channels. touchECG is designed to monitor and diagnose cardiac function. However, a Cardiologist must validate the results of the analysis run by the ECG. touchECG is intended for use in hospitals, clinics and outpatient departments of any size. It is suited for use at home and in emergencies (ambulances).   The device interprets the data for review by a doctor. The device must be used by a doctor or by specialised staff on behalf of an authorised doctor in clinical facilities. It is not intended as the only means for determining the diagnosis. The device's interpretation of the ECG analysis is only significant if used together with an additional analysis by the physician of reference and by an assessment of all the patient's important data. The device can be used on adult and paediatric patients. The device acquires, analyses, displays and prints out electrocardiograms. The device must not be used as a physiological monitoring of vital signs.

Open the catalog to page 1
touchECG System conf. Package Windows HD+ - 2

Technical specifications Minimum requirements for the computer Operating System Windows 7, Windows 8.1, Windows 10 Quad core 1.6 GHz or higher Fr ee space on Hard Disk Laser (colour/BW) Additional applications Email application which supports the EML format (only required for the email File Upload feature) ECG acquisition (HD+ unit) ECG leads Patient cable 10 replaceable wire patient lead Sampling rate of the input stage Sampling rate for signal analysis Dynamic range Pacemaker detection Hardware detection coupled with digital convolution filter AAMI/IEC standard Front-end performance Data...

Open the catalog to page 2
touchECG System conf. Package Windows HD+ - 3

Acquires up to 30 minutes of 12-lead ECG per Review and can export/print track sections. Lead configuration Standard, Cabrera All leads, medians, corrected HR Average RR PR Interval QRS duration QT and QTc (Hodges formula) intervals QTc Bazett interval QTc Fridericia interval max R[V5];[V6] and S[V1] Sokolow-Lyon Index P, R, T axis. Glasgow algorithm for adults, paediatric, STEMI (optional) Internal archive stores up to 1000 ECGs at rest (10 seconds) Processing options Interpretation Glasgow algorithm for adults, paediatric, STEMI Exported formats SCP-PDF-XML-GDT Standard format Included in...

Open the catalog to page 3
touchECG System conf. Package Windows HD+ - 4

Regulations and Safety Classification according to MDD 93/42/EEC Class Rule 10 annex IX Directive 93/42/EEC and its amendments Notified Body GDPR Compliance (General Data Protection Regulation) Access control Through the use of username and password at Operating System level and installing an instance (each one with its own database to which only the corresponding user can access) of touchECG for each user. Data at rest protection By the system administrator, activating the encryption functions of the operating system. Audit trail Through the log of the Windows operating system, which...

Open the catalog to page 4
touchECG System conf. Package Windows HD+ - 5

Medical electrical equipment -- Part 1-11: General requirements for basic safety and essential performance -- Collateral standard: Requirements for medical electrical equipment and medical electrical systems used in the home healthcare environment. Partly applied – Applied in conjunction with HD+ Medical device software - Software life cycle processes Medical devices - Application of usability engineering to medical devices touchECG System config. package Windows HD+ reusable touchECG System config. package Windows HD+ AHA touchECG System config. package Android HD+ reusable AHA touchECG...

Open the catalog to page 5

All Cardioline catalogs and technical brochures

  1. pneumos500

    3 Pages

  2. xr600r

    3 Pages

  3. xr600m

    3 Pages

  4. xr450r

    3 Pages

  5. xr450m

    4 Pages

  6. xr100+ BP

    2 Pages

  7. xr100+

    2 Pages

  8. xr50+

    2 Pages

  9. Walk400h

    4 Pages

  10. Clickholter

    5 Pages

  11. HD+

    4 Pages

  12. ECGWebApp

    9 Pages

  13. Walk200b

    4 Pages

  14. ECG200L

    5 Pages

  15. ECG100L

    5 Pages

  16. ECG100S

    7 Pages

  17. ECG100+

    7 Pages

  18. ECG200S

    7 Pages

  19. ECG200+

    7 Pages

  20. Cubeabpm

    3 Pages