Ultima Plus

Ultima Plus

Product catalog summary
Introduction
The document provides details about a patented monofocal intraocular lens (IOL) technology developed by Caregroup Sight Solution Private Limited. The lens is designed for smooth insertion and optimal positioning within the eye, featuring a 360° square edge to reduce posterior capsule opacification (PCO) and an aspheric optic for aberration neutrality, enhancing visual acuity and contrast.

Specifications
  • Material: Hydrophilic Acrylic
  • IOL Powers: +10.0 D to +30.0 Diopter in 0.5 D steps
  • Optic Diameter: 6.00 mm
  • Overall Length: Ultima - 12.50 mm, Ultima 4Q - 11.00 mm
  • Optic Type: Aspheric Optic
  • Haptic Angulation: 0° (Plano)
  • Haptic Configuration: Ultima - Modified C-L Haptic, Ultima 4Q - Four Haptic
  • Refractive Index: 1.465
  • A-Constant: Ultima - 117.9 (SRK-T, US Biometry), 118.4 (SRK-T, Optical Biometry); Ultima 4Q - 118.04 (SRK-T, US Biometry), 118.28 (SRK-T, Optical Biometry)

Recommendations
Surgeons are advised to derive their own values based on the specific characteristics of the patient's eye and the IOL to be used.

Contact Information
Caregroup Sight Solution Private Limited, Block No.: 310/C&E, Village Dabhasa, Taluka - Padra, Dist. Vadodara - 391 440, Gujarat, India. Email: [email protected]. Websites: www.caregroupindia.com, www.caregroupiol.com
See more

Catalog excerpts

Ultima Plus-1

Patented Technology Foldable Hydrophilic Aspheric Intraocular Lens Ÿ The lens design ensures smooth insertion and proper Positioning inside the eye. Ÿ The 360° Square Edge reduces the incidence of PCO. Ÿ Biconvex Aspheric Optic ensures that the lens Is virtually Aberration Neutral Ÿ Better visual Acuity and Enhanced Contrast Overall Length Overall Length Innovative Intraocular Lens Aspheric Optic | Foldable Acrylic 360° Square Edge | Aberration Neutral Hydrophilic Acrylic Optic Diameter Overall Length Optic Type Aspheric Optic Haptic Angulation Haptic Configuration Refractive Index 118.4 ( SRK-T, Optical Biometry )* 118.28 ( SRK-T, Optical Biometry )* Four Haptic *The values are of estimates only. It is recommended that the surgeon derive his / her own values based on data of the eye to be operated upon & characteristic of IOL. CAREGROUP SIGHT SOLUTION PRIVATE LIMITED Block No.: 310/C&E, Village Dabhasa, Taluka - Padra, Dist. Vadodara - 391 440, Gujarat, India. [email protected] www.caregroupindia.com | www.caregroupiol

 Open the catalog to page 1

All Care Group catalogs and technical brochures

  1. AcriDIFF

    1  Page

  2. Ocuflex

    1  Page