Iota II Anesthesia Workstation-1

Ventilation Modes : •Adult, Pediatric, Neonate •Volume Controlled Ventilation (VCV) •Pressure Controlled Ventilation (PCV) •Synchronized Intermittent Mandatory Ventilation (SIMV-V & SIMV-P) •Pressure Support Ventilation (PSV) •Manual Ventilation Parameters & Ranges : •Pressure Target: 5 ~ 70 cmH20 •Pressure Support (delta P): 5 ~ 60 cmH20 •Pressure (limit): 5 ~ 60 cmH20 •Tidal Volume: •Breathing Freq.: •T insp : •Electronic PEEP: •Freq min: •Tpause: •Trigger: •I :E Ratio: •Vaporizers: 20 ~ 1500 mL 0 ~ 100 bpm (4 ~ 60 bpm in SIMV) 0.5 ~ 5.0 s OFF, 3 ~ 39 cH20 2 ~ 60 bpm 0% ~ 60% of inspiratory time Flow & Pressure Trigger 10:1 ~ 1:10 Sevoflurane,lsoflurane, Halothane, Enflurane Monitoring : •Tidal Volume (VTI & VTE): 0 ~ 2000 mL •Minute Volume: 0 ~ 100 L •Breathing Rate: 0 ~ 100 bpm •Ppeak: -20 ~ 100 cmH20 •FO2: 21% ~ 100% •Waveform: P-T, F-T, C02-T (optional) •Loop: F-V, V-P •0thers: Pmean, PEEP, Pplat, Pmin, MVspont, Ratespont, Cdyn, Sp02 (optional), Pulse (optional), EtC02 (optional). InC02 (optional), N0 concentration (optional), Anesthetic agent concentration (optional), Flow of 02/N20 / Air, Total flow C €0123 Alarms: •3 level visible audible alarm •Sp02 (optional) •Adjustable alarm limits for Inspiratory 02 Concentration (Fi02) •Adjustable alarm limits for Minute Volume (MV) •Adjustable alarm limits for Airway Pressure (PAW) •Adjustable alarm limits for EtC02 and Agents (optional) •Continuous Pressure •02 Supply Failure •Apnea •High Breath Rate •Pulse (optional) •Low Battery •AC Power Failure •Technical Alarms Physical Specifications & 0peration Conditions: •Dimensions: 600 mm * 740 mm * 1368 mm (L*W*H) •Weight: 120 kg •Screen 12" TFT touchscreen •Casters: 10 cm diameter, with individual locking brakes in front •Two drawers •Power Supply: 100 ~ 240 V (AC ±10%), 50/60 Hz (±1%) •Battery backup: 4 hours •Power consumption: <75 VA Vaporizer: •Dual vaporizer postions •Mounting: Selectatec compatible with interlock, tool free installation •Filling Type: Pour-fill, Easy-fill, Quick-fill CareX Medical LLC 1402 W. Monmouth Ct. Richmond, VA 23238 USA Iota IIAnesthesia Workstation

 Open the catalog to page 1

All CareX Medical catalogs and technical brochures

  1. Sigma II

    1  Page

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.