16TJ
32Pages

{{requestButtons}}

Catalog excerpts

16TJ - 1

Product Data 16TJ Single-Effect, Steam Hermetic Absorption Liquid Chiller 100 to 700 Nominal Tons Carrier-Sanyo’s 16TJ single-effect hermetic absorption liquid chiller is an efficient and functional alternative to traditional electric driven chillers. The 16TJ absorption chiller uses lowpressure steam as its energy source; as it eliminates the need for high cost electricity, it may qualify for financial incentives as a gas cooling product. The 16TJ absorption chiller offers functional flexibility in a variety of installations: • no CFCs; environmentally sound • single stage design for simple, dependable operation • high reliability with few moving parts • nominal full-load steam rate of 17.2 lb/hr-ton • quiet, vibration-free operation • Direct Digital Controls (DDC) for optimum chiller performance Features/Benefits Single-effect absorption cycle provides efficient, economical water chilling with minimal use of electricity. Cost-effective cooling Alternative-energy chiller — The 16TJ chiller is a solution for building owners who want to avoid high operating costs associated with electric driven chillers. Powered by low-pressure steam, the Carrier-Sanyo 16TJ absorption chiller reduces or eliminates electric demand and/or ratchet charges while allowing the owner to take advantage of gas cooling incentives when offered by local utility companies. Copyright 2005 Carrier Corporation

Open the catalog to page 1
16TJ - 2

Features/Benefits (cont) Simple, reliable operation — The 16TJ chiller’s single generator provides one stage of solution reconcentration, which makes the 16TJ chiller one of the most basic cycles currently available. The 16TJ chiller’s simple design, in addition to its other quality features, equates to inherently high reliability. Few moving parts and simple, dependable operation reduce downtime, as well as service and maintenance costs. Exceptional efficiency — The 16TJ chiller offers full-load steam rates of 17.2 lb/hr-ton at standard ARI (Air Conditioning and Refrigeration Institute)...

Open the catalog to page 2
16TJ - 3

Microprocessor control features/benefits Each 16TJ single-effect chiller includes a pre-programmed, factory-mounted and factory-wired control panel, which is functionally tested prior to shipment. Chiller monitoring and control is automatic and continuous, and the screen on the front panel displays chiller operational status and fault indications in English or metric units. The Carrier-Sanyo microprocessor PID (proportional, integral, derivative) control system surpasses proportional only control systems by maintaining precise leaving chilled water temperature versus actual set point. The...

Open the catalog to page 3
16TJ - 4

Features/Benefits (cont) Automatic purge extends machine life, ensures optimum efficiency and performance The purge system on an absorption chiller is essential to ensuring long machine life and efficient operation. All absorption chillers operate in a vacuum and generate hydrogen (and other noncondensable gases) in small quantities, even when they are vacuum tight and properly inhibited. If not properly controlled, these gases can interfere with machine operation, therefore it is imperative that they be removed to protect against internal corrosion, lithium bromide solution...

Open the catalog to page 4
16TJ - 5

16TJ ABSORPTION CHILLER COOLING CYCLE Cooling Water Outlet Steam Inlet Steam Drain Reclaimer Steam Drain Outlet Chilled Water Outlet Chilled Water Inlet Evaporator Absorber Refrigerant Pump Absorbent Pump Cooling Water Inlet Heat Exchanger Purge Pump

Open the catalog to page 5
16TJ - 6

Model number nomenclature 16 16 – Hermetic Absorption Chiller TJ – Single Effect,Steam (1-Stage) Options and accessories FACTORY-INSTALLED OPTION X X ITEM Cooling Water Flow Switch High-Pressure Waterboxes, 300 psig Isolation Package Marine Waterboxes Shipping Configuration (1-piece or 2-piece) Special Tubing Steam Control Valve (Electric or Pneumatic) Thermometer Set Victaulic Nozzle Connections FIELD-INSTALLED ACCESSORY

Open the catalog to page 6
16TJ - 7

Machine components CONDENSER STEAM INLET STEAM DRAIN OUTLET GENERATOR CHILLED WATER OUTLET EVAPORATOR CHILLED WATER INLET COOLING WATER INLET CONTROL PANEL HEAT EXCHANGER HEAT RECLAIMER

Open the catalog to page 7
16TJ - 8

UNIT 16TJ NOMINAL COOLING CAPACITY (ton) RIGGING WEIGHT (lb) OPERATING WEIGHT (lb) LITHIUM BROMIDE SOLUTION CHARGE (lb) REFRIGERANT (WATER) CHARGE (lb) CHILLED WATER Pipe Connection Size (in.) No. of Passes COOLING WATER Pipe Connection Size (in.) No. of Passes Absorber Condenser STEAM Pipe Connection Size (in.) Steam Inlet Drain Outlet UNIT 16TJ NOMINAL COOLING CAPACITY (ton) RIGGING WEIGHT (lb) OPERATING WEIGHT (lb) LITHIUM BROMIDE SOLUTION CHARGE (lb) REFRIGERANT (WATER) CHARGE (lb) CHILLED WATER Pipe Connection Size (in.) No. of Passes COOLING WATER Pipe Connection Size (in.) No. of...

Open the catalog to page 8
16TJ - 9

indicates the position of anchor bolts. 4. For routine maintenance allow 3 ft clearance on all sides and 8 in. above chiller. 5. For tube removal clearance, refer to drawing. 6. Standard water piping connections are ANSI 150 lb flanges. 7. Pass quantity and nozzle locations are for standard machine; other configurations are available. NOTES: 1. Dimensions are shown in inches. 2. Dimensions (L), (W), (H) are for standard machine. LEGEND ANSI — American National Standards Institute CHW — Chilled Water COW — Cooling Water

Open the catalog to page 9
16TJ - 10

indicates the position of anchor bolts. 4. For routine maintenance allow 3 ft clearance on all sides and 8 in. above chiller. 5. For tube removal clearance, refer to drawing. 6. Standard water piping connections are ANSI 150 lb flanges. 7. Pass quantity and nozzle locations are for standard machines; other configurations are available. NOTES: 1. Dimensions are shown in inches. 2. Dimensions (L), (W), (H) are for standard machine. LEGEND ANSI — American National Standards Institute CHW — Chilled Water COW — Cooling Water Dimensions (cont)

Open the catalog to page 10
16TJ - 11

indicates the position of anchor bolts. 4. For routine maintenance allow 3 ft clearance on all sides and 8 in. above chiller. 5. For tube removal clearance, refer to drawing. 6. Standard water piping connections are ANSI 150 lb flanges. 7. Pass quantity and locations are for standard machine; other configurations are available. NOTES: 1. Dimensions are shown in inches. 2. Dimensions (L), (W), (H) are for standard machine. LEGEND ANSI — American National Standards Institute CHW — Chilled Water COW — Cooling Water

Open the catalog to page 11

All Carrier| Commercial Systems North America catalogs and technical brochures

  1. Axis™

    2 Pages

  2. AHUBuilder

    2 Pages

  3. 50ZPB

    4 Pages

  4. 39CC

    2 Pages

  5. 48PG CENTURION?

    107 Pages

  6. 48XL-A

    30 Pages

  7. OMNIZONE?

    80 Pages

  8. 39S

    36 Pages

  9. 39L AERO®

    52 Pages

  10. 39M AERO®

    110 Pages

Archived catalogs