30RB AQUASNAP®
92Pages

{{requestButtons}}

Catalog excerpts

30RB AQUASNAP® - 1

AQUASNAP® 30RB060-390 Air-Cooled Chillers Product Data The AquaSnap chiller is an effective allin-one package that is easy to install and easy to own. AquaSnap chillers cost less to purchase and install, and then operate quietly and efficiently. Value-added features include: • Rotary scroll compression • Puron® HFC refrigerant (R-410A) • Quiet AeroAcoustic™ fan system • Easy to use ComfortLink controls • Optional full heat reclaim package • Optional integrated hydronic pump package, available with variable frequency drive (VFD) • Novation® heat exchanger technology with microchannel coil Features/Benefits Carrier’s superior chiller design provides savings at initial purchase, at installation, and for years afterward. Costs less right from the start Carrier’s AquaSnap chillers feature a compact, all-in-one package design that installs quickly and easily on the ground or the rooftop. The optional pump and hydronic components are already built in; this costs less than buying and installing the components individually. The chiller’s fully integrated and pre-assembled hydronic system installs in minutes. No other chiller in this class installs so easily and inexpensively. The preassembled and integrated hydronic module (available with VFD) utilizes top-quality components and pumps to ensure years of reliable operation. The AquaSnap unit’s high efficiency keeps operating costs down. * Meets IBC 2006, ASCE-7-05, CBC 2007, and OSHPD seismic requirements. Copyright 2012 Carrier Corporation

Open the catalog to page 1
30RB AQUASNAP® - 2

Features/Benefits (cont) AquaSnap® chillers make noise in the marketplace, not the workplace The AquaSnap chiller’s AeroAcoustic™ fan is almost twice as quiet as the competition’s per cfm. Much of the noise reduction is in frequencies where noise is most annoying, which makes AquaSnap chillers ideal for soundsensitive environments. When lower ambient temperatures allow part load operation or during scheduled nighttime operation, the units operate with fewer fans and become even quieter. AquaSnap chillers are quiet during the day and even quieter at night. The savings will continue to mount...

Open the catalog to page 2
30RB AQUASNAP® - 3

Due to the compact all aluminum design, microchannel coils will reduce overall unit operating weight by 6 to 7%. The streamlined MCHX coil design reduces refrigerant charge by up to 30%. The coil is designed with rubber isolation around the powder painted coil frame to eliminate galvanic couples which can cause corrosion due to dissimilar metals. Optional integrated heat reclaim package For applications with a simultaneous requirement for chilled water and tempered heat water, the heat reclaim option is an ideal solution. MODE Run Status Service Test MOD E Alarm Run Status Servic e Tes t...

Open the catalog to page 3
30RB AQUASNAP® - 4

Model number nomenclature 30RB - Air-Cooled AquaSnap® Chiller Design Series Nominal Sizes Condenser Coil Option - - Aluminum Fin/Copper Tube 0 - Copper Fin/Copper Tube 1 - Aluminum Pre-Coat Fin/Copper Tube 2 - Aluminum E-Coat Fin/Copper Tube 3 - Copper E-Coat Fin/Copper Tube 5 - E-Coat, MicroChannel (MCHX) Hydronics Option 8 - Dual Pump, 7.5 HP, Low Head 9 - Dual Pump, 7.5 HP, High Head F - Single Pump, 3 HP with VFD G- Single Pump, 5 HP with VFD H- Single Pump, 7.5 HP with VFD J - Single Pump, 10 HP with VFD K- Single Pump, 15 HP with VFD M- Dual Pump, 3 HP with VFD N - Dual Pump, 5 HP...

Open the catalog to page 4
30RB AQUASNAP® - 5

LEGEND Coefficient of Performance Energy Efficiency Ratios Integrated Part Load Value Pressure Drop *Air Conditioning, Heating, and Refrigeration Institute. NOTE: Based on AHRI 550/590 standard rating conditions. Ratings are for standard chillers only. Ratings do not include options.

Open the catalog to page 5
30RB AQUASNAP® - 6

Physical data 30RB060-300 — ENGLISH UNIT 30RB OPERATING WEIGHT (lb)* Al-Cu Condenser Coil Cu-Cu Condenser Coil MCHX Condenser Coil REFRIGERANT TYPE Refrigerant Charge (lb) Std Coil, Ckt A/Ckt B/Ckt C MCHX Coil, Ckt A/Ckt B/Ckt C COMPRESSORS Quantity Speed (rpm) (Qty) Compressor Model Number Ckt A (Qty) Compressor Model Number Ckt B (Qty) Compressor Model Number Ckt C Oil Charge (Pt, Ckt A/Ckt B/Ckt C) No. Capacity Steps Standard Optional (Maximum) Minimum Capacity Step (%) Standard Optional Capacity (%) Ckt A Ckt B Ckt C COOLER Weight (empty, lb) Net Fluid Volume (gal) Maximum Refrigerant...

Open the catalog to page 6
30RB AQUASNAP® - 7

UNIT 30RB OPERATING WEIGHT (lb)* Al-Cu Condenser Coil Cu-Cu Condenser Coil MCHX Condenser Coil REFRIGERANT TYPE Refrigerant Charge (lb) Std Coil, Ckt A/Ckt B/Ckt C MCHX Coil, Ckt A/Ckt B/Ckt C COMPRESSORS Quantity Speed (rpm) (Qty) Compressor Model Number Ckt A (Qty) Compressor Model Number Ckt B (Qty) Compressor Model Number Ckt C Oil Charge (Pt, Ckt A/Ckt B/Ckt C) No. Capacity Steps Standard Optional (Maximum) Minimum Capacity Step (%) Standard Optional Capacity (%) Ckt A Ckt B Ckt C COOLER Weight (empty, lb) Net Fluid Volume (gal) Maximum Refrigerant Pressure (psig) Maximum Water-Side...

Open the catalog to page 7
30RB AQUASNAP® - 8

Physical data (cont) 30RB060-300 — SI UNIT 30RB OPERATING WEIGHT (kg)* Al-Cu Condenser Coil Cu-Cu Condenser Coil MCHX Condenser Coil REFRIGERANT TYPE Refrigerant Charge (kg) Std Coil, Ckt A/Ckt B/Ckt C MCHX Coil, Ckt A/Ckt B/Ckt C COMPRESSORS Quantity Speed (r/s) (Qty) Compressor Model Number Ckt A (Qty) Compressor Model Number Ckt B (Qty) Compressor Model Number Ckt C Oil Charge (L, Ckt A/Ckt B/Ckt C) No. Capacity Steps Standard Optional (Maximum) Minimum Capacity Step (%) Standard Optional Capacity (%) Ckt A Ckt B Ckt C COOLER Weight (empty, kg) Net Fluid Volume (L) Maximum Refrigerant...

Open the catalog to page 8
30RB AQUASNAP® - 9

OPERATING WEIGHT (kg)* Al-Cu Condenser Coil Cu-Cu Condenser Coil MCHX Condenser Coil REFRIGERANT TYPE Refrigerant Charge (kg) Std Coil, Ckt A/Ckt B/Ckt C MCHX Coil, Ckt A/Ckt B/Ckt C COMPRESSORS Quantity Speed (r/s) (Qty) Compressor Model Number Ckt A (Qty) Compressor Model Number Ckt B (Qty) Compressor Model Number Ckt C Oil Charge (L, Ckt A/Ckt B/Ckt C) No. Capacity Steps Standard Optional (Maximum) Minimum Capacity Step (%) Standard Optional Capacity (%) Ckt A Ckt B Ckt C COOLER Weight (empty, kg) Net Fluid Volume (L) Maximum Refrigerant Pressure (kPa) Maximum Water-Side Pressure without...

Open the catalog to page 9

All Carrier| Commercial Systems North America catalogs and technical brochures

  1. Axis™

    2 Pages

  2. AHUBuilder

    2 Pages

  3. 50ZPB

    4 Pages

  4. 39CC

    2 Pages

  5. 48PG CENTURION?

    107 Pages

  6. 48XL-A

    30 Pages

  7. OMNIZONE?

    80 Pages

  8. 16TJ

    32 Pages

  9. 39S

    36 Pages

  10. 39L AERO®

    52 Pages

  11. 39M AERO®

    110 Pages

Archived catalogs