Overview: The document provides comprehensive technical specifications and operational guidelines for the AquaSnap chiller by Carrier Corporation, focusing on the 30RB series. It highlights the chiller's compact design, efficiency, and suitability for sound-sensitive environments.
Key Features:
  • Rotary Scroll Compression: Ensures smooth and reliable operation.
  • Puron® HFC Refrigerant (R-410A): Environmentally friendly and non-ozone depleting.
  • AeroAcoustic™ Fan System: Significantly reduces noise.
  • ComfortLink Controls: User-friendly interface for monitoring and control.
  • Optional Packages: Includes heat reclaim and integrated hydronic pump packages.
  • Novation® Heat Exchanger Technology: Enhances efficiency and reduces refrigerant charge.
Benefits:
  • Cost Efficiency: Lower initial and installation costs.
  • Operational Savings: High energy efficiency with EER up to 9.7 and IPLV up to 14.2.
  • Proven Reliability: 12-month warranty and maintenance-free compressors.
  • Environmental Responsibility: Uses safe and non-toxic refrigerant.
  • Structural Integrity: Built with durable materials.
Technical Specifications:
  • Capacity Range: 60 to 390 nominal tons (210 to 1370 kW).
  • Seismic Compliance: Meets IBC 2006, ASCE-7-05, CBC 2007, and OSHPD requirements.
  • Operating Temperature Range: From -20°F (-29°C) to 125°F (52°C).
Optional Features:
  • Integrated Hydronics Package: Includes pumps, strainer, flow regulator, and freeze protection.
  • Heat Reclaim Package: Suitable for applications requiring both chilled and tempered heat water.
Control and Communication:
  • ComfortLink Controls: Provides detailed diagnostics and operational data.
  • Navigator™ Display: Handheld device for quick diagnostics.
  • Network Compatibility: Compatible with Carrier Comfort Network® and BACnet communication options.
Conclusion: The AquaSnap chiller is a versatile and efficient solution for various cooling needs, offering significant cost savings, reliability, and environmental benefits.
Electrical Specifications:
Units are designed for specific electrical systems with voltage limits and phase imbalance allowances. Each unit requires a single point primary power connection, and wiring must be rated at a minimum of 75°C using copper wire.
Performance Metrics: Includes Coefficient of Performance (COP), Energy Efficiency Ratios (EER), and Integrated Part Load Value (IPLV). Pressure Drop (PD) values are also provided.
Components: Equipped with direct expansion, shell and tube type coolers, and shrouded axial type condenser fans.
Refrigerant and Oil Charge: Detailed refrigerant charge information is provided for standard and MCHX coils, along with oil charge specifications for different compressor circuits.
Physical Dimensions: Includes chassis dimensions in both feet-inches and millimeters.
Control Features: The ComfortLink system includes standard control functions coordinated through a master chiller controller, requiring communication links and additional thermistors for parallel chillers.
Capacity Control: Offers various capacity control steps, which may vary due to compressor sequencing.
Safety Protocols: Includes multiple safety features such as low-temperature and high-temperature overrides, low-pressure and high-pressure cutouts, and compressor anti-cycling.
Installation and Wiring: Detailed wiring instructions and notes emphasize compliance with UL standards and applicable codes.
Variable-Speed Pumping System: Discusses the advantages of variable-speed pumping systems, including energy savings and reduced maintenance.
Sensorless Technology: Employs sensorless technology, eliminating the need for remote sensors.
Chiller Operation: For multiple chiller applications, drives must be synchronized to prevent surging.
Freeze Protection: Options are available, with recommendations for antifreeze solutions based on ambient conditions.
Energy Management: Techniques such as demand limiting and temperature reset are recommended for efficient energy management.
See more

Catalog excerpts

30RB AQUASNAP®-1

AQUASNAP® 30RB060-390 Air-Cooled Chillers Product Data The AquaSnap chiller is an effective allin-one package that is easy to install and easy to own. AquaSnap chillers cost less to purchase and install, and then operate quietly and efficiently. Value-added features include: • Rotary scroll compression • Puron® HFC refrigerant (R-410A) • Quiet AeroAcoustic™ fan system • Easy to use ComfortLink controls • Optional full heat reclaim package • Optional integrated hydronic pump package, available with variable frequency drive (VFD) • Novation® heat exchanger technology with microchannel coil Features/Benefits Carrier’s superior chiller design provides savings at initial purchase, at installation, and for years afterward. Costs less right from the start Carrier’s AquaSnap chillers feature a compact, all-in-one package design that installs quickly and easily on the ground or the rooftop. The optional pump and hydronic components are already built in; this costs less than buying and installing the components individually. The chiller’s fully integrated and pre-assembled hydronic system installs in minutes. No other chiller in this class installs so easily and inexpensively. The preassembled and integrated hydronic module (available with VFD) utilizes top-quality components and pumps to ensure years of reliable operation. The AquaSnap unit’s high efficiency keeps operating costs down. * Meets IBC 2006, ASCE-7-05, CBC 2007, and OSHPD seismic requirements. Copyright 2012 Carrier Corporation

 Open the catalog to page 1
30RB AQUASNAP®-2

Features/Benefits (cont) AquaSnap® chillers make noise in the marketplace, not the workplace The AquaSnap chiller’s AeroAcoustic™ fan is almost twice as quiet as the competition’s per cfm. Much of the noise reduction is in frequencies where noise is most annoying, which makes AquaSnap chillers ideal for soundsensitive environments. When lower ambient temperatures allow part load operation or during scheduled nighttime operation, the units operate with fewer fans and become even quieter. AquaSnap chillers are quiet during the day and even quieter at night. The savings will continue to mount Besides...

 Open the catalog to page 2
30RB AQUASNAP®-3

Due to the compact all aluminum design, microchannel coils will reduce overall unit operating weight by 6 to 7%. The streamlined MCHX coil design reduces refrigerant charge by up to 30%. The coil is designed with rubber isolation around the powder painted coil frame to eliminate galvanic couples which can cause corrosion due to dissimilar metals. Optional integrated heat reclaim package For applications with a simultaneous requirement for chilled water and tempered heat water, the heat reclaim option is an ideal solution. MODE Run Status Service Test MOD E Alarm Run Status Servic e Tes t perat...

 Open the catalog to page 3
30RB AQUASNAP®-4

Model number nomenclature 30RB - Air-Cooled AquaSnap® Chiller Design Series Nominal Sizes Condenser Coil Option - - Aluminum Fin/Copper Tube 0 - Copper Fin/Copper Tube 1 - Aluminum Pre-Coat Fin/Copper Tube 2 - Aluminum E-Coat Fin/Copper Tube 3 - Copper E-Coat Fin/Copper Tube 5 - E-Coat, MicroChannel (MCHX) Hydronics Option 8 - Dual Pump, 7.5 HP, Low Head 9 - Dual Pump, 7.5 HP, High Head F - Single Pump, 3 HP with VFD G- Single Pump, 5 HP with VFD H- Single Pump, 7.5 HP with VFD J - Single Pump, 10 HP with VFD K- Single Pump, 15 HP with VFD M- Dual Pump, 3 HP with VFD N - Dual Pump, 5 HP with...

 Open the catalog to page 4
30RB AQUASNAP®-5

LEGEND Coefficient of Performance Energy Efficiency Ratios Integrated Part Load Value Pressure Drop *Air Conditioning, Heating, and Refrigeration Institute. NOTE: Based on AHRI 550/590 standard rating conditions. Ratings are for standard chillers only. Ratings do not include options.

 Open the catalog to page 5
30RB AQUASNAP®-6

Physical data 30RB060-300 — ENGLISH UNIT 30RB OPERATING WEIGHT (lb)* Al-Cu Condenser Coil Cu-Cu Condenser Coil MCHX Condenser Coil REFRIGERANT TYPE Refrigerant Charge (lb) Std Coil, Ckt A/Ckt B/Ckt C MCHX Coil, Ckt A/Ckt B/Ckt C COMPRESSORS Quantity Speed (rpm) (Qty) Compressor Model Number Ckt A (Qty) Compressor Model Number Ckt B (Qty) Compressor Model Number Ckt C Oil Charge (Pt, Ckt A/Ckt B/Ckt C) No. Capacity Steps Standard Optional (Maximum) Minimum Capacity Step (%) Standard Optional Capacity (%) Ckt A Ckt B Ckt C COOLER Weight (empty, lb) Net Fluid Volume (gal) Maximum Refrigerant Pressure...

 Open the catalog to page 6
30RB AQUASNAP®-7

UNIT 30RB OPERATING WEIGHT (lb)* Al-Cu Condenser Coil Cu-Cu Condenser Coil MCHX Condenser Coil REFRIGERANT TYPE Refrigerant Charge (lb) Std Coil, Ckt A/Ckt B/Ckt C MCHX Coil, Ckt A/Ckt B/Ckt C COMPRESSORS Quantity Speed (rpm) (Qty) Compressor Model Number Ckt A (Qty) Compressor Model Number Ckt B (Qty) Compressor Model Number Ckt C Oil Charge (Pt, Ckt A/Ckt B/Ckt C) No. Capacity Steps Standard Optional (Maximum) Minimum Capacity Step (%) Standard Optional Capacity (%) Ckt A Ckt B Ckt C COOLER Weight (empty, lb) Net Fluid Volume (gal) Maximum Refrigerant Pressure (psig) Maximum Water-Side Pressure...

 Open the catalog to page 7
30RB AQUASNAP®-8

Physical data (cont) 30RB060-300 — SI UNIT 30RB OPERATING WEIGHT (kg)* Al-Cu Condenser Coil Cu-Cu Condenser Coil MCHX Condenser Coil REFRIGERANT TYPE Refrigerant Charge (kg) Std Coil, Ckt A/Ckt B/Ckt C MCHX Coil, Ckt A/Ckt B/Ckt C COMPRESSORS Quantity Speed (r/s) (Qty) Compressor Model Number Ckt A (Qty) Compressor Model Number Ckt B (Qty) Compressor Model Number Ckt C Oil Charge (L, Ckt A/Ckt B/Ckt C) No. Capacity Steps Standard Optional (Maximum) Minimum Capacity Step (%) Standard Optional Capacity (%) Ckt A Ckt B Ckt C COOLER Weight (empty, kg) Net Fluid Volume (L) Maximum Refrigerant Pressure...

 Open the catalog to page 8
30RB AQUASNAP®-9

OPERATING WEIGHT (kg)* Al-Cu Condenser Coil Cu-Cu Condenser Coil MCHX Condenser Coil REFRIGERANT TYPE Refrigerant Charge (kg) Std Coil, Ckt A/Ckt B/Ckt C MCHX Coil, Ckt A/Ckt B/Ckt C COMPRESSORS Quantity Speed (r/s) (Qty) Compressor Model Number Ckt A (Qty) Compressor Model Number Ckt B (Qty) Compressor Model Number Ckt C Oil Charge (L, Ckt A/Ckt B/Ckt C) No. Capacity Steps Standard Optional (Maximum) Minimum Capacity Step (%) Standard Optional Capacity (%) Ckt A Ckt B Ckt C COOLER Weight (empty, kg) Net Fluid Volume (L) Maximum Refrigerant Pressure (kPa) Maximum Water-Side Pressure without Pumps...

 Open the catalog to page 9

All Carrier| Commercial Systems North America catalogs and technical brochures

  1. Axis™

    2  Pages

Archived catalogs

  1. 50ZPB

    4  Pages

  2. AHUBuilder

    2  Pages

  3. 39CC

    2  Pages

  4. 48XL-A

    30  Pages

  5. 48PM CENTURION?

    64  Pages

  6. 48PG CENTURION?

    107  Pages

  7. OMNIZONE?

    80  Pages

  8. 39L AERO®

    52  Pages

  9. 39S

    36  Pages

  10. AQUAFORCE® 30XA

    150  Pages

  11. 16TJ

    32  Pages

  12. 39M AERO®

    110  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.