video corpo

48P WEATHERMASTER®

48P WEATHERMASTER®
1 / 168 PagesView full catalog

48P WEATHERMASTER®

Product catalog summary
Overview: Carrier's 48/50P Series commercial packaged rooftop units are designed for flexibility, reliability, and environmental responsibility. They feature Puron® refrigerant (R-410A), Novation® heat exchanger technology, and ComfortLink controls for enhanced system integration and efficiency.
Key Features:
  • Refrigerant: Utilizes Puron® (R-410A), an environmentally sound refrigerant that does not harm the ozone layer.
  • Heat Exchanger: Novation® technology with microchannel coils for reduced weight and refrigerant charge, offering robust and cost-effective performance.
  • Compressors: Includes scroll compressors with an option for digital scroll compressors for variable capacity control.
  • Control Systems: ComfortLink controls support CV, SAV™, and VAV operations, with capabilities for BACnet, MODBUS, and LonWorks protocols.
  • Dehumidification: Humidi-MiZer® adaptive system for enhanced dehumidification and comfort.
Design Flexibility: The units are adaptable for various applications, offering options for different fan sizes, heating methods, and economizer configurations. They can be configured for vertical or horizontal discharge and include options for high-capacity exhaust systems.
Quality and Reliability: The units are designed with multiple scroll compressors and dual refrigerant circuits for efficiency and reliability. They include features like crankcase heaters and electronic sensors for protection and optimal performance.
Indoor Air Quality (IAQ): Features include a sloped stainless steel condensate drain pan and optional double wall construction with anti-microbial coating to maintain air quality and prevent microbial growth.
Control and Monitoring: The ComfortLink system provides extensive control capabilities, including adaptive optimal start/stop, economizer control, and demand limiting. It supports integration with building automation systems for comprehensive monitoring and control.
Installation and Serviceability:
  • Hinged access panels for easy service access without removing fasteners.
  • Single-point electrical connections standard on all units.
  • Factory run testing ensures successful start-up.
  • ETL and ETL Canada listed according to UL Standard 1995.
  • Scrolling marquee for easier serviceability, including alarm monitoring and self-diagnostic run testing.
  • Suction and discharge pressure transducers for remote monitoring and energy consumption reduction.
  • Factory-installed non-fused disconnect option for simplified installation and improved serviceability.
Gas Heat Units (48P Units):
  • Natural gas combustion with two heat sizes available per unit.
  • Multiple heat exchanger sections with 2-stage redundant gas valve and independent ignition control.
  • Optional modulating gas heat for precise temperature control.
  • Heat exchanger design optimizes heat transfer for improved efficiency and durability.
  • Integrated gas unit controller (IGC) for system evaluation and troubleshooting.
  • Induced draft fan system for effective heat transfer and combustion process.
Model Number Nomenclature: The document provides a detailed breakdown of model numbers, including configuration, voltage options, heat and chassis options, and unit size. It emphasizes the use of Applied Rooftop Builder software to generate the correct option code for unit model numbers.
Quality Assurance: The units are certified to ISO 9001 standards.
Unit Design Airflow Limits: The document includes tables specifying minimum and maximum cooling CFM for various unit sizes and configurations.
Two-Stage Gas Heating Capacities: Detailed tables provide gas input, efficiency, output capacity, temperature rise, and airflow for different unit sizes and configurations.
Cooling Capacities Overview: This document provides detailed specifications and performance data for cooling systems, specifically focusing on the 48/50P series units. The data includes various parameters such as Bypass Factor (BF), Compressor Motor Power Input (kW), Entering Dry Bulb (Edb), Sensible Heat Capacity (SHC), Entering Wet Bulb (Ewb), and Total Capacity (TC) in 1000 Btuh.
Fan Performance Overview: This document provides detailed fan performance data for various units, specifically focusing on models 50P2, P3, P4, P5, and 48/50P series. The performance is measured in terms of airflow (cfm), available external static pressure (in. wg), revolutions per minute (Rpm), and brake horsepower (Bhp).
Control Components: The 48/50P Series rooftops use the ComfortLink control system, which includes several key components such as Main Base Board (MBB), Rooftop Control Board (RXB), Compressor Expansion Board (CXB), and more. The control system supports communication with various protocols including BACnet, MODBUS, and LonWorks, facilitating integration with broader building management systems.
Cooling Control Options: The P Series ComfortLink controls offer various cooling control methods, including constant volume, SAV™, and VAV, each with multiple stages of cooling. The controls can manage the staging of compressors, with different configurations based on unit size.
Heating Control Options: The units can be equipped with various heating options, including 2-stage electric or gas heat, multiple-stage gas heat, and modulating gas or hydronic heat.
Economizer and IAQ Options: The controls support indoor air quality management through the use of outside air economizers, which can be configured for full modulation or 3-position operation.
Additional Features: The units can be equipped with various filters and a filter pressure drop switch to indicate dirty filter conditions. The system supports building pressure control through barometric relief dampers, power exhaust fans, and modulating return fans.
System Description: The units are outdoor, roof-curb mounted, electronically controlled heating and cooling systems. They utilize hermetic scroll compressors for cooling and gas combustion for heating. The units can supply and return air either vertically or horizontally.
Quality Assurance: The units conform to various standards including AHRI Standard 340/360, ANSI/ASHRAE 15, ASHRAE 62, UL Standard 1995, and others.
Product Specifications:
  • Equipment: The units are factory-assembled with all necessary wiring, piping, refrigerant charge, and control systems. They include dual refrigerant circuits and microprocessor-based control systems.
  • Unit Cabinet: Constructed of galvanized steel with a baked polyester finish, the cabinet is designed to withstand salt spray tests and includes insulated, double-wall access doors.
  • Fans: The supply fan is a centrifugal belt-driven type, isolated from the unit casing with spring isolators. Condenser fans are direct-driven propeller types with corrosion-resistant construction.
  • Compressors: The document details the use of hermetic scroll compressors with crankcase heaters for cooling duty.
Operational Guidelines:
  • Airflow: The units operate with specific airflow limits to prevent condensate blow-off and ensure efficient heating and cooling.
  • Temperature Limits: The units are designed to operate at outdoor temperatures ranging from -20 F to 115 F, with specific recommendations for high altitude and low-temperature operations.
  • Installation Recommendations: Guidelines are provided for ductwork installation, thermostat use, and auxiliary coil applications, emphasizing the need for low-temperature protection in outdoor installations.
Additional Features: The document includes detailed diagrams and schematics for wiring and control systems, as well as a comprehensive legend for understanding the technical terminology used.
See more

Catalog excerpts

48P WEATHERMASTER®-1

Product Data WEATHERMASTER® 48/50P2,P3,P4,P5030-100 Single-Package Gas Heating/Electric Cooling Rooftop Units and Electric Cooling Rooftop Units with Optional Electric Heat with ComfortLink Controls and PURON® Refrigerant (R-410A) 30 to 100 Nominal Tons Carrier’s 48/50P Series commercial packaged rooftops offer: • Puron® refrigerant (R-410A) • Novation® heat exchanger technology with microchannel coil • scroll compressors • digital scroll compressor option • constant volume (CV) • staged air volume (SAV™) • variable air volume (VAV) • vertical supply/return units • horizontal supply/return units • flexible chassis and plenum options • optional return fan/modulating power exhaust • optional high-capacity modulating power exhaust • staged gas control option for supply air tempering • optional modulating gas heat • hydronic heat option • high-capacity evaporator coil • optional airfoil fan • Humidi-MiZer® adaptive dehumidification option Features/Benefits Carrier’s 48/50P commercial packaged unit offers design flexibility, quality, reliability, interoperability and ComfortLink controls. ComfortLink controls Factory-installed ComfortLink controls provide the capability for free standing operation or may be linked with a more extensive system. Factory-installed and programmed BACnet* communication capability provides simple integration with the building HVAC system (e.g., terminal devices), an i-Vu® Open control system or a BACnet building automation system. Form 48/50P-7PD

 Open the catalog to page 1
48P WEATHERMASTER®-2

Features/Benefits (cont) ComfortLink controls also have the capability to communicate with the Carrier Comfort Network® (CCN) system. This communication flexibility allows simple system integration as well as data collection, trending, monitoring and alarm displays. The 48/50P Series may also be configured to communicate via MODBUS† or LonWorks** protocols if required by the application. The ComfortLink controls can also interface directly with BACnet or CCN controls on 35 and 45 Series VAV terminals to form a system for optimal efficiency and tenant comfort. All units may also be applied to...

 Open the catalog to page 2
48P WEATHERMASTER®-3

applications. Microchannel coils are also sturdier than other coil types, making them easier to clean without causing damage to the coil. Due to the compact all aluminum design, microchannel coils reduce overall unit operating weight. The streamlined microchannel coil also reduces refrigerant charge by up to 40%. Microchannel coils are not recommended by Carrier for marine, coastal, or industrial environments unless a Carrier-approved coating is applied. Digital scroll compressor In air conditioning applications, the load may vary significantly, requiring a means to vary the system capacity for...

 Open the catalog to page 3
48P WEATHERMASTER®-4

Features/Benefits (cont) Design flexibility The P Series rooftop units with ComfortLink controls are designed to meet all customer requirements for new construction, replacement jobs, or special applications. The customer can choose from the following: • CV, SAV™ or VAV applications • digital scoll compressors • 4 or more supply-fan motor sizes • 2 sizes of natural gas heat (48 Series units) • electric heat (50 Series units) • hydronic heat (50 Series units) • Novation® microchannel (MCHX) condenser coils or e-coated MCHX condenser coils • integrated economizer with low-leak dampers, barometric...

 Open the catalog to page 4
48P WEATHERMASTER®-5

Run testing — To ensure a successful start-up, every rooftop unit is factory run tested. Unit design — Unit design is ETL and ETL, Canada, listed according to UL (Underwriters Laboratories) Standard 1995. Scrolling marquee — When using the standard scrolling marquee, serviceability becomes even easier, including: • local or remote alarm and alert monitoring • self-diagnostic run testing to confirm control and component operation • expedited troubleshooting and unit repair through self-diagnostic display of unit troubleshooting alert and alarm codes with expanded text descriptions to immediately...

 Open the catalog to page 5
48P WEATHERMASTER®-6

Model number nomenclature 48P2,P3,P4,P5 UNITS Option Code Factory Options See note below 48 – Cooling Unit with Gas Heat Configuration P2 – Vertical Suppy/Return, CV/SAV ComfortLink Controls P3 – Vertical Supply/Return, VAV ComfortLink Controls P4 – Horizontal Suppy/Return, CV/SAV ComfortLink Controls P5 – Horizontal Suppy/Return, VAV ComfortLink Controls Heat and Chassis Options – – Low Gas Heat, Humidi-MiZer® System A – High Gas Heat, Humidi-MiZer System B – Low Gas Heat, Stainless Steel C – High Gas Heat, Stainless Steel D – Low Gas Heat E – High Gas Heat F – Low Staged Gas Heat, Stainless...

 Open the catalog to page 6
48P WEATHERMASTER®-7

Ratings and capacities UNIT DESIGN AIRFLOW LIMITS UNIT SIZE UNIT TYPE 48P2,P3,P4,P5 Low Heat 48P2,P3,P4,P5 High Heat 50P2,P3,P4,P5 48P2,P3,P4,P5 Low Heat 48P2,P3,P4,P5 High Heat 50P2,P3,P4,P5 48P2,P3,P4,P5 Low Heat 48P2,P3,P4,P5 High Heat 50P2,P3,P4,P5 48P2,P3,P4,P5 Low Heat 48P2,P3,P4,P5 High Heat 50P2,P3,P4,P5 48P2,P3,P4,P5 Low Heat 48P2,P3,P4,P5 High Heat 50P2,P3,P4,P5 48P2,P3,P4,P5 Low Heat 48P2,P3,P4,P5 High Heat 50P2,P3,P4,P5 48P2,P3,P4,P5 Low Heat 48P2,P3,P4,P5 High Heat 50P2,P3,P4,P5 48P2,P3,P4,P5 Low Heat 48P2,P3,P4,P5 High Heat 50P2,P3,P4,P5 48P2,P3,P4,P5 Low Heat 48P2,P3,P4,P5 High...

 Open the catalog to page 7
48P WEATHERMASTER®-8

Ratings and capacities (cont) TWO-STAGE GAS HEATING CAPACITIES — 48P4,P5 UNITS (Natural Gas on All Units and LP Gas Not Available) UNIT 48P4,P5 030-050 Low Heat 030-050 High Heat 055-070 Low Heat 055-070 High Heat 075-100 Low Heat 075-100 High Heat 3. At altitudes above 2000 ft, the following formula may be used: LP — Liquid Propane NOTES: 1. Ratings are approved for altitudes to 2000 ft. At altitudes over 2000 ft, ratings are 4% less for each 1000 ft above sea level. 2. At altitudes up to 2000 ft, the following formula may be used to calculate air temperature rise: maximum output capacity 1.10...

 Open the catalog to page 8

All Carrier| Commercial Systems North America catalogs and technical brochures

  1. Axis™

    2  Pages

Archived catalogs

  1. 50ZPB

    4  Pages

  2. AHUBuilder

    2  Pages

  3. 39CC

    2  Pages

  4. 48XL-A

    30  Pages

  5. 48PM CENTURION?

    64  Pages

  6. 48PG CENTURION?

    107  Pages

  7. OMNIZONE?

    80  Pages

  8. 39L AERO®

    52  Pages

  9. 39S

    36  Pages

  10. 30RB AQUASNAP®

    92  Pages

  11. AQUAFORCE® 30XA

    150  Pages

  12. 16TJ

    32  Pages

  13. 39M AERO®

    110  Pages