Overview: The Infinity® 15 SEER Single-Packaged Air Conditioner and Gas Furnace System with Puron® (R-410A) Refrigerant is a single-phase unit available in sizes from 2 to 5 nominal tons. It features energy-saving components and environmentally friendly refrigerant.
Key Features: The system includes direct spark ignition, up to 15.5 SEER and 12.0 EER, meets Energy Star requirements, up to 80.1% AFUE, low sound levels, variable-speed blower, factory-installed TXV, stainless steel heat exchanger, two-stage cooling and heating, and advanced dehumidification.
Benefits: Offers low sound levels, easy installation, low maintenance, and dependable performance. Uses Puron® refrigerant, which is environmentally friendly. Provides greater comfort, humidity control, and energy efficiency through IdealHumidity™ Technology and Infinity® control.
Design and Installation: Features a high-tech composite material base to prevent rust and includes a sloped drain pan to inhibit mold and bacterial growth. Designed for easy installation with a factory-assembled package that is pre-wired, pre-piped, and pre-charged. Configurable for downflow or horizontal applications.
Efficiency and Operation: High efficiency with SEER ratings up to 15.5 and AFUE ratings up to 80.1%. Includes energy-saving features like direct spark ignition and a low-cost propane conversion kit. The 48XLN-A models are Low NOx units suitable for California installations.
Components and Construction: Includes durable components such as two-stage scroll compressors, monoport inshot burners, and turbo-tubular heat exchangers made of 409 stainless steel. Features a full-featured ECM motor and direct-drive PSC condenser fan motors.
Additional Features: Includes an Infinity User Interface, reliable refrigerant system, thermostatic expansion valve, high- and low-pressure switches, and computer-designed indoor and outdoor coils for optimal heat transfer and cooling efficiency. Designed for quiet operation with sound ratings as low as 75 dBA.
Specifications: Provides detailed specifications, including model number nomenclature, AHRI capacities, physical data, options and accessories, dimensions, selection procedure, performance data, typical piping and wiring, application data, electrical data, and wiring schematic.
Performance Data: Includes detailed performance data for HVAC systems, including bypass factor, entering and leaving dry-bulb and wet-bulb temperatures, total unit power input, sensible heat capacity, and total capacity. Provides formulas for calculating sensible capacity and total capacity based on airflow and temperature differences.
Natural and Propane Gas Orifice Sizes: Outlines orifice sizes and manifold pressure settings for natural and propane gas systems at various altitudes. Specifies adjustments needed for installations above 2000 ft in the U.S.A. and Canada.
High Altitude Compensation: Provides tables for adjusting heating input ratings for natural and propane gas systems at different altitudes. Specifies the percentage reduction required for installations above 2000 ft in the U.S.A. and Canada.
Air Delivery Data: Includes tables for wet/dry coil air delivery at low and high stages, specifying airflow rates (CFM) for different unit sizes and external static pressures.
Application Data: Provides guidelines for condensate trap installation, ductwork attachment, and unit conversion for downflow discharge. Specifies minimum and maximum operating temperatures for cooling.
Electrical Data: Lists electrical specifications for various unit sizes, including voltage range, compressor and fan motor ratings, and minimum circuit amps.
Wiring Schematics: Contains connection and ladder wiring schematics for different gas input ratings, providing detailed diagrams for installation and troubleshooting.
Controls and Operation: Describes the sequence of operation for cooling and gas heat modes, including inducer motor operation, ignition sequence, and flame proving.
Guide Specifications: Provides specifications for single-packaged air conditioner and gas furnace systems, including system description, quality assurance standards, and compliance with industry standards such as AHRI, UL, ANSI, and NFPA.
Equipment Components: Includes fans, compressors, coils, heating section, refrigerant metering device, filters, controls, and safeties.
Operating Characteristics: The unit can operate at ambient temperatures from 125°F (51.6°C) to 0°F (-17.7°C) with low ambient cooling enabled.
Special Features: Includes a low NOx option for natural gas models, factory-installed louvered grille, optional tin-plated indoor refrigerant coils, Infinity User Interface, and various kits for altitude compensation, gas conversion, and duct transitions.
48XL---A Infinity® 15 SEER Single---Packaged Air Conditioner and Gas Furnace System with Puron® (R---410A) Refrigerant Single Phase 2---5 Nominal Tons (Sizes 24---60) Product Data Innovative Unit Base Design On the inside a high-tech composite material will not rust and incorporates a sloped drain pan which improves drainage and helps inhibit mold, algae and bacterial growth. On the outside metal base rails provide added stability as well as easier handling and rigging. Variable-Speed Blower motors provide better comfort and energy efficiency. Economical constant airflow which provides improved indoor air quality and more even temperatures from room to room; and reduced indoor noise due to lower air velocity. In addition, you’ll realize improved installation flexibility with 3 different airflow choices for best overall comfort. Easy installation Factory-assembled package is a compact, fully self-contained, combination gas heating/electric cooling unit that is pre-wired, pre-piped, and pre-charged for minimum installation expense. These units are available in a variety of standard and optional heating/cooling size combinations. Units are lightweight and install easily on a rooftop or at ground level. The high tech composite unit base eliminates rust problems associated with ground level applications. A09032 Fig. 1 - Unit 48XL-A Single-Packaged Products with Energy-Saving Features and Puron® refrigerant. S Direct Spark Ignition S Up to 15.5 SEER S Up to 12.0 EER S Meets Energy Star requirements S Up to 80.1% AFUE S Low Sound Levels S Variable-Speed Blower (Standard) S Factory Installed TXV S Stainless Steel Heat Exchanger S Two Stage Cooling and Heating S Advanced Dehumidification Feature FEATURES/BENEFITS One-piece heating and cooling units with low sound levels, easy installation, low maintenance, and dependable performance. -Sound Refrigerant is Carrier’s unique Puron® Environmentallyrefrigerant designed to help protect the environment. Puron refrigerant is an HFC refrigerant which does not contain chlorine that can harm the ozone layer. Puron refrigerant is in service in millions of systems proving highly reliable, environmentally sound performance. IdealHumidityt Technology featuring Infinityr control and Variable-Speed Blower motor and two-stages of cooling and heating provide greater comfort, humidity control, and energy efficiency. Convertible duct configuration Unit is designed for use in either downflow or horizontal applications. Each unit is converted from horizontal to downflow and includes horizontal duct covers. Downflow operation is provided in the field to allow vertical ductwork connections. The basepan seals on the bottom openings to ensure a positive seal in the vertical airflow mode. Efficient operation High-efficiency design with SEERs (Seasonal Energy Efficiency Ratio) of up to 15.5 and AFUE (Annual Fuel Utilization Efficiency) ratings as high at 80.1%. Energy-saving, direct spark ignition saves gas by operating only when the room thermostat calls for heating. Standard units are furnished with natural gas controls. A low-cost field installed kit for propane conversion is available for all units. 48XLN- units are dedicated Low NOx units designed for -A California installations. These models meet the California maximum oxides of nitrogen (NOx) emissions requirement of 40 nanograms/joule or less as shipped from the factory and MUST be installed in California Air Quality Management Districts or any other location where a Low NOx rule exists. Durable, dependable components Compressors have two stages of cooling and are designed for high efficiency. Each compressor is hermetically sealed against contamination to help promote longer life and dependable operation. Vibration isolation provides quiet operation. Compressors have internal high-pressure and overcurrent protection. Monoport inshot burners produce precise air- -gas mixture, -towhich provides for clean and efficient combustion. The large monoport on the inshot (or injection type) burners seldom, if ever, 1
Open the catalog to page 1requires cleaning. All gas furnace components are accessible in one compartment. Turbo-tubulart heat exchangers are constructed of 409 stainless steel for corrosion resistance and optimum heat transfer for improved efficiency. The tubular design permits hot gases to make multiple passes across the path of the supply air. In addition, dimples located on the heat exchanger walls force the hot gases to stay in close contact with the walls, improving heat transfer. Full featured ECM Motor is standard on all 48XL- models. -A Direct-drive, PSC (Permanent Split Capacitor) condenser fan motors are designed...
Open the catalog to page 2FEATURES/BENEFITS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 MODEL NUMBER NOMENCLATURE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 AHRI CAPACITIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 PHYSICAL DATA . . . . ....
Open the catalog to page 3AHRI* CAPACITIES Cooling Capacities, Efficiencies Unit 48XL- A - Nominal Tons Standard CFM (High / Low Stage) Net Cooling Capacities (Btuh) (High / Low Stage) Heating Input (Btuh) High/Low Output Capacity (Btuh) High / Low Temperature Rise Range High °F (°C) Temperature Rise Range Low °F (°C) LEGEND db—Dry Bulb SEER—Seasonal Energy Efficiency Ratio wb—Wet Bulb COP—Coefficient of Performance HSPF—Heating Season Performance Factor * Air Conditioning, Heating & Refrigeration Institute. ** Ratings are net values, reflecting the effects of circulating fan heat. Ratings are based on: Cooling Standard:...
Open the catalog to page 4PHYSICAL DATA UNIT SIZE COMPRESSORS Quantity REFRIGERANT: PURON (R--- 410A) Quantity (lb) (kg) REFRIGERANT METERING DEVICE Size OUTDOOR COIL Rows...Fins/in. Face Area (sq ft) OUTDOOR FAN Nominal Cfm Diameter (in.) (mm) Motor Hp (Rpm) INDOOR COIL Rows...Fins/in. Face Area (sq ft) INDOOR FAN Nominal Airflow (Cfm) Comfort Efficiency Max Furnace (gas ht.) airflow---Low Stage Furnace (gas ht.) airflow---High Stage Size (in.) (mm) Motor HP (RPM) FURNACE SECTION* Burner Orifice No. Natural Gas Qty...Drill Size (Factory Installed) Propane Gas Qty...Drill Size HIGH--- PRESSURE SWITCH (psig) Reset (Auto)...
Open the catalog to page 5116 Pages
2 Pages
24 Pages
44 Pages
2 Pages
4 Pages
2 Pages
6 Pages
8 Pages
6 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
6 Pages
32 Pages
116 Pages
52 Pages
124 Pages
64 Pages
107 Pages
116 Pages
168 Pages
26 Pages
80 Pages
52 Pages
88 Pages
36 Pages
92 Pages
32 Pages
150 Pages
60 Pages
52 Pages
32 Pages
36 Pages
110 Pages
56 Pages
2 Pages