48XL Infinity? 15
26Pages

{{requestButtons}}

Catalog excerpts

48XL Infinity? 15 - 1

48XL/48XLN Infinityt 15 SEER Single---Packaged Air Conditioner and Gas Furnace System w/PuronR (R---410A) Refrigerant 2---5 Nominal Tons (Sizes 024---060) Product Data IdealHumidityt Technology featuring Infinityt control and Variable-Speed Blower motor and two-stages of cooling and heating provide greater comfort, humidity control, and energy efficiency. Variable-Speed Blower motors provide better comfort and energy efficiency. You can expect up to 30 times better dehumidification; economical constant fan for less than $50 a year, which provides improved indoor air quality and more even temperatures from room to room; and reduced indoor noise due to lower air velocity. In addition, you’ll realize improved installation flexibility with 3 different airflow choices for best overall comfort. Easy installation Factory-assembled package is a compact, fully self-contained, combination gas heating/electric cooling unit that is pre-wired, pre-piped, and pre-charged for minimum installation expense. These units are available in a variety of standard and optional heating/cooling size combinations. Units are lightweight and install easily on a rooftop or at ground level. The high tech composite unit base eliminates rust problems associated with ground level applications. Convertible duct configuration A05307 Fig. 1 - Unit 48XL Single-Packaged Products with Energy-Saving Features and Puron® refrigerant. S Direct Spark Ignition S Up to 15.5 SEER S Meets Energy Star requirements S Up to 80.1% AFUE S Low Sound Levels S Variable-Speed Blower (Standard) S Factory Installed TXV S Stainless Steel Heat Exchanger (Limited Lifetime Warranty) S Two Stage Cooling and Heating FEATURES/BENEFITS One-piece heating and cooling units with low sound levels, easy installation, low maintenance, and dependable performance. -Sound Refrigerant is Carrier’s unique Puron® Environmentallyrefrigerant designed to help protect the environment. Puron refrigerant is an HFC refrigerant which does not contain chlorine that can harm the ozone layer. Puron refrigerant is in service in millions of systems proving highly reliable, environmentally sound performance. Unit is designed for easy use in either downflow or horizontal applications. Each unit is easily converted from horizontal to downflow and includes horizontal duct covers. Downflow operation is easily provided in the field to allow vertical ductwork connections. The basepan utilizes knockout style seals on the bottom openings to ensure a positive seal in the horizontal airflow mode. Efficient operation High-efficiency design with SEERs (Seasonal Energy Efficiency Ratio) of up to 15.5 and AFUE (Annual Fuel Utilization Efficiency) ratings as high at 80.1%. Energy-saving, direct spark ignition saves gas by operating only when the room thermostat calls for heating. Standard units are furnished with natural gas controls. A low-cost field installed kit for propane conversion is available for all units. 48XLN units are dedicated Low NOx units designed for California installations. These models meet the California maximum oxides of nitrogen (NOx) emissions requirement of 40 nanograms/joule or less as shipped from the factory and MUST be installed in California Air Quality Management Districts or any other location where a Low NOx rule exists. Durable, dependable components Compressors have two stages of cooling and are designed for high efficiency. Each compressor is hermetically sealed against contamination to help promote longer life and dependable operation. Vibration isolation provides quiet operation. Compressors have internal high-pressure and overcurrent protection. 1

Open the catalog to page 1
48XL Infinity? 15 - 2

Monoport inshot burners produce precise air- -gas mixture, -towhich provides for clean and efficient combustion. The large monoport on the inshot (or injection type) burners seldom, if ever, requires cleaning. All gas furnace components are accessible in one compartment. Turbo-tubulart heat exchangers are constructed of 409 stainless steel for corrosion resistance and optimum heat transfer for improved efficiency. The tubular design permits hot gases to make multiple passes across the path of the supply air. In addition, dimples located on the heat exchanger walls force the hot gases to...

Open the catalog to page 2
48XL Infinity? 15 - 3

FEATURES/BENEFITS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 MODEL NUMBER NOMENCLATURE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 ARI CAPACITIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 PHYSICAL DATA . . ....

Open the catalog to page 3
48XL Infinity? 15 - 4

ARI* CAPACITIES Cooling Capacities, Efficiencies Unit 48XL Nominal Tons Standard CFM (High / Low Stage) Net Cooling Capacities (Btuh) (High / Low Stage) Heating Input (Btuh) High/Low Output Capacity (Btuh) High / Low Temperature Rise Range High °F (°C) Temperature Rise Range Low °F (°C) LEGEND db—Dry Bulb SEER—Seasonal Energy Efficiency Ratio wb—Wet Bulb COP—Coefficient of Performance HSPF—Heating Season Performance Factor * Air Conditioning & Refrigeration Institute. ** Ratings are net values, reflecting the effects of circulating fan heat. Ratings are based on: Cooling Standard: 80°F...

Open the catalog to page 4
48XL Infinity? 15 - 5

PHYSICAL DATA COMPRESSORS Quantity REFRIGERANT: PURON (R --- 410A) Quantity (lb) (kg) REFRIGERANT METERING DEVICE Size Part Number OUTDOOR COIL Rows...Fins/in. Face Area (sq ft) OUTDOOR FAN Nominal Cfm Diameter (in.) (mm) Motor Hp (Rpm) INDOOR COIL Rows...Fins/in. Face Area (sq ft) INDOOR FAN Nominal Airflow (Cfm) Comfort Efficiency Max Furnace (gas ht.) airflow---Low Stage Furnace (gas ht.) airflow---High Stage Size (in.) (mm) Motor HP (RPM) FURNACE SECTION* Burner Orifice No. (Qty...Drill Size) Natural Gas HIGH --- PRESSURE SWITCH (psig) Cut---out Reset (Auto) HIGH--- PRESSURE SWITCH 2...

Open the catalog to page 5

All Carrier| Commercial Systems North America catalogs and technical brochures

  1. Axis™

    2 Pages

  2. AHUBuilder

    2 Pages

  3. 50ZPB

    4 Pages

  4. 39CC

    2 Pages

  5. 48PG CENTURION?

    107 Pages

  6. 48XL-A

    30 Pages

  7. OMNIZONE?

    80 Pages

  8. 16TJ

    32 Pages

  9. 39S

    36 Pages

  10. 39L AERO®

    52 Pages

  11. 39M AERO®

    110 Pages

Archived catalogs